FACTORY INSTALLED AIR INTAKE FAN SPEED CONTROLLER
<br /> FACTORY INSTALLED UNIT-MOUNTEDT
<br /> MECHANICAL EQUIPMENT SCHEDULES HOOD WITH FACTORY INSTALLED DISCONNECT WITH SINGLE POINT FACTORY-MOUNTED W o
<br /> MOTORIZED OUTSIDE AIR DAMPER FACTORY MOUNTED INSIDE FAN HOUSING. c"J co
<br /> ELECTRICAL SERVICE CONNECTION. DISCONNECT UNDER L - ` x o
<br /> �, a�
<br /> GAS FLUE HOOD J FAN w � X coo
<br /> >< N
<br /> SELF CONTAINED ROOFTOP A/C UNIT - GAS FIRED HEATCD M
<br /> RE: 5M2.1 FOR ROOF INSULATION x
<br /> FACTORY INSTALLED FLOAT SWITCH IN UNIT W Q
<br /> CONDENSATE RTU DRAIN PAN. UPON ACTIVATION OF FLOAT CANTSTRIP Q LL
<br /> TAG TONS CFM O.A. EXT. * COOLING COOLING EVA HEATING HEATING AFUE WEIGHT REMARKS DRAIN DETAIL SWITCH, UNIT SHALL SHUT DOWN. ROOFING v 0 0
<br /> CFM S.P.,IN MBTUH EFFICIENCY ELECTRICAL DATA FAN INPUT OUTPUT (LBS) UNION ------- ''„ C12 C?
<br /> W.G. SENS. TOTAL EER IEER VOLTS PH. HZ MCA MOCP H.P. BTUH BTUH D H� O o M
<br /> RTU-1 8.5 3400 660 1.0 54.3 103.8 12.2 12.9 208 3 60 47 50 3 130,000 104,000 80% 1,600 ❑� ❑2 ❑s ® ❑5 © ❑7 ® ❑9 ROOF DECK GAS / DIRT LEG FACTORY ROOF CURB m N
<br /> RTU-2 13.0 5200 1531 1.0 75.7 155.4 12.0 13.2 208 3 60 72 80 5 169,000 135,000 80% 2,650 i 2 3 4 5 s 7 a COCK SUPPORT ANGLES, AS BACKDRAFT DAMPER o a
<br /> ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ PIPE SUPPORT, TYPICAL co
<br /> SD RE: 2P2.1 REQUIRED, BY GENERAL EXHAUST DUCT cc
<br /> CONTRACTOR (DESIGNED `�1-1/2" EXTERNAL INSULATION
<br /> Q `J BY STRUCTURAL ENGINEER (EXHAUST DUCT ONLY). EXTEND
<br /> GENERAL NOTES: OF RECORD). INSULATION BEYOND ROOF
<br /> 1. PROVIDE UNIT WITH 2" MERV-13 FILTERS. FILTERS ASSUMED TO BE PART OF INTERNAL STATIC PRESSURE. FACTORY ROOF CURB, FLASHED INTO ROOFING INSULATION.
<br /> 2. CONDITIONS BASED ON 100`F AIR ENTERING CONDENSER. SYSTEM PER ROOFING CONTRACTOR'S
<br /> 3. UNITS SHALL UTILIZE R-410A REFRIGERANT. I REQUIREMENTS. COORDINATE WITH ROOFING ELECTRIC CONDUIT
<br /> 4. ROOFTOP UNITS SHALL BE LENNOX ENERGENCE SERIES. UNITS SHALL BE FURNISHED BY OWNER AND INSTALLED BY CONTRACTOR. CONTRACTOR. BY ELECTRICAL
<br /> LENNOX INDUSTRIES NATIONAL ACCOUNT MANAGER ED WRIGHT: (972)752-4071, ED.WRIGHT@LENNOXIND.COM. CONTRACTOR SHALL FLEXIBLE CONNECTION,
<br /> COORDINATE START-UP OF EACH UNIT WITH LENNOX INDUSTRIES. TYPICAL SUPPORT ANGLES, AS REQUIRED,
<br /> 5. RTU-1 IS BASED ON A NOMINAL 8.5-TON UNIT. RTU-2 IS BASED ON A NOMINAL 13-TON UNIT. FACTORY INSTALLED BY GENERAL CONTRACTOR CURB MOUNTING FOR ROOF- store:
<br /> SUPPLY AIR SMOKE MOUNTED TOILET ROOM EXHAUST FAN 1311E YOSEMITE AVE
<br /> NOTES: DETECTORS. CONDUIT WINDOW
<br /> ❑� 41 N.T.S.PROVIDE 14" FACTORY ROOF CURB WITH FACTORY RESTRAINT BRACKETS TO SECURE UNIT TO CURB. CONTROL WIRE CONDUIT BY MECHANICAL MANTECA, CA 95336
<br /> 0 PROVIDE FACTORY CS7500 THERMOSTAT. PROVIDE REMOTE TEMPERATURE/HUMIDITY SENSORS AS SHOWN ON PLANS. ROOFTOP UNIT DETAIL ELECTRIC CONDUIT BY ELECTRICAL
<br /> N.T.S. Restaurant #RC529
<br /> 0 PROVIDE FACTORY UNIT-MOUNTED DISCONNECT, OUTSIDE AIR DAMPER AND HOOD, DIRTY FILTER SWITCH, 21
<br /> CONVENIENCE OUTLET (FIELD WIRED), SINGLE POINT ELECTRICAL SERVICE CONNECTION, AND SA SMOKE DETECTORS. ROOFTOP UNIT 1-1/2" DRAIN
<br /> ® PROVIDE CLEAR PLEXIGLASS LOCKABLE THERMOSTAT BOX. COOLING COIL TRAP AND VENT Professional of Record:
<br /> 0 DRAIN PAN 1-1/2" DRAIN LINE,SLOPE AT 1
<br /> BRANCH DUCT RUNOUT WITH /PROVIDE LENNOX FACTORY INSTALLED HUMIDITROL HOT GAS REHEAT OPTION AND REMOTE HUMIDITY SENSOR. GALVANIZED SHEET METAL GALVANIZED SHEET METAL ROUND 4" PER
<br /> © DUCT WRAP INSULATION OVER ADJUSTABLE ELBOW. ADJUST ROOFTOP FOOT, MINIMUM
<br /> RE: MECHANICAL GENERAL NOTES. AIR UNIT
<br /> PROVIDE FACTORY INSTALLED AIR ECONOMIZER WITH DIFFERENTIAL ENTHALPY CONTROL. PROVIDE SOLID-STATE ENTHALPY SENSORS SHEET METAL ELBOW, MITER ELBOW ANGLE TO MATCH TURNING EXTERNAL DUCT WRAP INSULATION. 6"
<br /> AT MANUFACTURER'S RECOMMENDED LOCATIONS. CUT INSULATION TO ELIMINATE ANGLE OF RUNOUT DUCT. - - -
<br /> 0 PROVIDE FACTORY INSTALLED DOWNFLOW BAROMETRIC RELIEF DAMPERS. FACTORY INSTALL DAMPERS WITH ECONOMIZER. EXCESS. SPIN-TAP FITTING WITH ADJUSTABLE GASKETING AT__-----=
<br /> MAX 5 FT. (INNER CORE) DAMPER, RE: SPECS. TOP OF CURB
<br /> ® PROVIDE FACTORY MESH HAIL/COIL GUARDS. MESH HAIL/COIL GUARDS SHALL BE FIELD INSTALLED. FOR RECTANGULAR OR SQUARE LENGTH PRE-INSULATED *-1/2" BUILT-UP
<br /> CONNECTIONS FROM DUCT TO FLEXIBLE DUCT, RE: SPECS. FACTORY ROOF ROOF SYSTEM
<br /> 0
<br /> EXTERNALLY WRAPPED SUPPLY DUCT. ROBISON
<br /> PROVIDE CO2 SENSOR FOR DEMAND CONTROL VENTILATION REQUIREMENTS. DIFFUSER, USE #8x1/2" LONG, TRIM INNER CORE LENGTH TO SEE MECHANICAL SPECIFICATIONS. CURB
<br /> AIR DEVICE SCHEDULE SELF-TAPPING HEX HEAD SHEET ELIMINATE EXCESS AND
<br /> METAL SCREWS AT 8"O.C. MAXIMUM SAGGING. ROOF D=C�
<br /> ENGINEERING, INC
<br /> AND AT LEAST ONE SCREW PER
<br /> 19401 40TH AVE W.,SUITE 302
<br /> SIDE. FOR ROUND CONNECTIONS, ROOFTOP UNIT LYNNWOOD,WA 98036
<br /> MANUFACTURER/ USE A MINIMUM OF FOUR EQUALLY 206.364,3343 TEL
<br /> TYPE MATERIAL FINISH ACCESSORIES MODEL # SIZE BORDER TYPE SPACED #8x1/2" LONG, ,. • SUPPORT AND DRAIN DETAIL
<br /> SELF-TAPPING HEX-HEAD SHEET i N.T.S. REI# 424-1497
<br /> METAL SCREWS. 51
<br /> CEILING DIFFUSER (CD-1) ALUMINUM SEE NOTE ❑ AG-100 TITUS/TDC-AA 24x24 MODULE TYPE 3
<br /> CEILING DIFFUSER (CD-2) ALUMINUM SEE NOTE ❑ AG-100 TITUS/TDC-AA 12x12 DIM. A TYPE 1 INSULATE TOPS OF NOTES:
<br /> CEILING DIFFUSERCD-3 ALUMINUM SEE NOTE 1 AG-100 TITUS/TDC-AA 6x6 DITYPE 1 DIFFUSERS. l `L
<br /> ( ) ❑ - M. A 1. PROVIDE CLEANOUT AT EACH CHANGE OF ELEVATION, DIRECTION OR EVERY 30'-0".
<br /> CEILING DIFFUSER (CD-4) ALUMINUM SEE NOTE ❑ AG-100 TITUS/TMRA-AA 3❑ ® BUTT INSULATION TIGHT 2. SUPPORT DRAIN LINE SIMILAR TO PIPE SUPPORT DETAIL. RE: 2P2.1 FOR DETAIL.
<br /> CEILING DIFFUSER, AGAINST RECTANGULAR DUCT. QROFESS/pN
<br /> RETURN GRILLE ALUMINUM SEE NOTE1❑ 2❑ -- TITUS/350FLF1 48x24 MODULE TYPE 3 FRAME STYLE SHALL D• R ��
<br /> RETURN GRILLE ALUMINUM SEE NOTE1❑ 2❑ -- TITUS/350FLF1 30x30 DUCT TYPE 1 MATCH CEILING. DUCT WRAP INSULATION DAMPER OPERATOR HANDLE WITH
<br /> RE: AIR DEVICE SHALL OVERLAP FLEX POSITIVE LOCKING DEVICE, TRIM Q OZ
<br /> EXHAUST REGISTER ALUMINUM SEE NOTE1❑ AG-15 TITUS/350FL 12x12 DUCT TYPE 1 SCHEDULE DUCT INSULATION. INSULATION TO PREVENTASWEATING.OPERATOR AIR BALANCE SCHEDULE " M-2871
<br /> LU
<br /> SIDEWALL GRILLE (SWG) ALUMINUM WHITE AG-15 TITUS/300FS 6x6 DUCT TYPE 1 � EXP 0-21 �
<br /> SECURE INNER CORE TO METAL DUCT WITH DRAWBANDS, EITHER STAINLESS STEEL WORM DRIVEN (HOSE) CLAMP TYPE OR
<br /> GENERAL NOTES: UV-RESISTANT NYLON DUCT TIES TYPE. SEAL JOINTS WITH MASTIC OR PRESSURE SENSITIVE ALUMINUM FOIL TAPE. FLEXIBLE AIR
<br /> 1. CONTRACTOR SHALL COORDINATE AIR DEVICE FRAMES WITH CEILING AND/OR WALL TYPE. DUCTS SHALL BE TESTED IN ACCORDANCE WITH UL-181B AND CMC 603.5 AND SHALL BE LISTED AND LABELED AS CLASS 0 OR
<br /> 2. CFM QUANTITIES SHOWN ON MECHANICAL FLOOR PLANS. CLASS 1. F
<br /> ZONE DINING OF CALF
<br /> NOTES: ROUND DUCT BRANCH RUNOUT CONNECTION DETAIL
<br /> ❑i FINISH SHALL BE COORDINATED WITH ARCHITECTURAL PLANS. ❑3 DIFFUSER NECK SIZE SHALL BE AS DESIGNATED ON FLOOR PLANS. 3 UNIT SUPPLY AIR RETURN AIR OUTDOOR AIR EXHAUST AIR PRESSURE
<br /> N.T.S. 08/07/20
<br /> ❑2 PROVIDE REMOVABLE FACE AND KNURLED KNOB FASTENERS. ® DIFFUSER SHALL HAVE STANDARD BORDER (WITHOUT OPTIONAL OUTER CORE). RTU-1 3400 2755 660 +660
<br /> CEILING DIFFUSERS F-4 - - - 450 -450 Prototype: P4 EXTENDED- HV, SCHEMEA
<br /> TOP TRUSS CHORD SUBTOTAL 3400 2755 660 450 +210
<br /> Prototype Issue Date: 6.29.2020
<br /> DESIGNATION NECK MAX. CONNECTING MAX. PRESSURE DROP FOR SPIN TAP 25' STRAIGHT FLEXIBLE DUCT REMARKS Design Bulletin Updates: INCLUDED
<br /> SIZE DESIGN CFM DUCT SIZE AND DIFFUSER COMBINATION ZONE KITCHEN
<br /> THREADED ROD ANCHOR SCREWED INTO Date Issued: Bulletin Number:
<br /> A 6" DIA. 100 6" DIA. 0.15 SEE SPECS. PROVIDE SIDE OF WOOD TRUSS TOP CHORD RTU-2 5200 3669 1531 +1531
<br /> NYLON-INSERT NOV. 2018 1 & 2
<br /> © 8" DIA. 200 8" DIA. 0.15 SEE SPECS. LOCK NUTS WITH GALVANIZED ALL-THREAD ROD MAU-1 1710 +1710
<br /> © 10" DIA. 350 10" DIA. 0.15 SEE SPECS. WASHERS (SIZED PER SMACNA) MAU-2 3262 +3262 1ST BLDG. SUBMITTAL
<br /> OD 12" DIA. 500 12" DIA. 0.15 SEE SPECS. F-1 - - - 2475 -2475
<br /> PROVIDE SUPPORTS AT ENDS OF
<br /> OE 14" DIA. 650 14" DIA. 0.15 SEE SPECS. FULL-ROUND ALL SPIRAL DUCTS TO PREVENT F-2 - - - 1950 -1950
<br /> GALVANIZED olDUCTS FROM SAGGING.
<br /> NOTE: SUPPLIERS NOT ABLE TO MEET ANY OF THE ABOVE COMBINATIONS SHALL USE THE NEXT LARGER TYPE SCHEDULED. DUCT STRAP F-3 - - - 2138 -2138
<br /> FANS DUCT CHASE FRAMING SUBTOTAL 5200 3669 6503 6563 -60
<br /> DESIGNATION CFM S.P. RPM WHEEL DRIVE WHEEL MAX. ELECTRICAL DATA MANUFACTURER/MODEL REMARKS PROVIDE AFITTINGS AT ALL TOTALS 8600 6424 7163 7013 +150
<br /> IN. DIA. TYPE SONES JOINTS, SEEAMMKETED S AND CONNECTIONS OF
<br /> W.G. INCHES EXPOSED DUCTWORK. MASTICS SHALL❑1 ❑2 ❑3 ® ❑5 REVISIONS:
<br /> H.P. VOLTS PH , , , NOT BE USED ON EXPOSED DUCTWORK. INTAKE EXCEEDS EXHAUST FOR BUILDING PRESSURIZATION.
<br /> LOCAL BALANCE IN THE KITCHEN IS -60 CFM. 1 08-07-20 1st. Bldg. Submittal
<br /> MAU-1 1,710 0.5 1722 AS REQ'D -- -- -- 1.5 208 3 CAPTIVE-AIRF A1-15D-MPU ❑1 2
<br /> BOTTOM TRUSS CHORD
<br /> MAU-2 3,262 0.5 1240 AS REQ'D -- 2.0 208 3 CAPTIVE-AIRE A2-20D-MPU ❑2 3
<br /> F-1 2,475 1.75 1352 AS REQ'D DIRECT CENT -- 1.5 208 3 CAPTIVE-AIRE DU180HFA ❑2 4
<br /> F-2 11950 2.0 1,383 AS REQ'D DIRECT CENT -- 1.5 208 3 CAPTIVE-AIRE DU180HFA ❑2 5
<br /> SPIRAL DUCT SUPPORT 6
<br /> F-3 2,138 1.75 1316 AS REQ'D DIRECT CENT -- 1.5 208 3 CAPTIVE-AIRE DU180HFA 0 6
<br /> N.T.S. 7
<br /> F-4 450 0.375 997 AS REQ'D DIRECT CENT 6.0 1/4 120 1 GREENHECK ❑3 ,®,❑5 8
<br /> 9
<br /> ❑i MAKE-UP AIR FAN (MAU-1) SHALL BE ELECTRICALLY INTERLOCKED WITH THE HOOD EXHAUST FAN (F-3). OUTDOOR AIR REQUIREMENTS - 2019 CMC/CEC
<br /> 0 MAKE-UP AIR FAN (MAU-2) SHALL BE ELECTRICALLY INTERLOCKED WITH THE HOOD EXHAUST FAN (F-1) & (F-2). 81 91 AIR CURTAIN SCHEDULE
<br /> 0 UNIT SHALL BE INSTALLED WITH FACTORY ROOF CURB, BACKDRAFT DAMPER, DISCONNECT SWITCH LOCATED AT FAN, BIRDSCREEN, Sheet Title:
<br /> AND FAN SPEED CONTROLLER LOCATED AT FAN. MINIMUM OUTSIDE HVAC SCHEDULES
<br /> ® DESIGN FLOOR AREA REQUIRED AIR CURTAIN
<br /> OCC. (SQ.FT.) OUTSIDE TOILET ROOM EXHAUST SHALL BE INTERLOCKED WITH RTU-1 FOR CONTINUOUS OPERATION DURING ALL TIMES OF BUILDING DEVICE CLASSIFICATION RATE AIR REMARKS AND DETAILS
<br /> OCCUPANCY.
<br /> AIR SCHEDULE
<br /> 0 FAN SHALL BE GREENHECK G-SERIES. DESIGNATION MANUFACTURER MODEL CFM FPM MOTOR HP ELECTRICAL FLA WEIGHT
<br /> RTU-1 DINING ROOMS OR DINING HALLS 50 870 7.5 CFM/PERSON 435 CFM 660 CFM SEE BELOW Date: 08.07.2020
<br /> OR 0.5 CFM/SQ. FT. AC-1 MARS AIR LPV248-1 U 1200 1800 1/6 115V/1 P 2.4 40 LBS
<br /> RTU-2 KITCHENS (COOKING) 8 560 7.5 CFM/PERSON 127 CFM 750 CFM SEE BELOW Project Number: RAC19024.0
<br /> 0.12 CFM/SQ. FT. AC-2 MARS AIR LPV225-1 U 625 1800 1/6 115V/1 P 2.4 20 LBS
<br /> 7.5 CFM/PERSON AC-3 MARS AIR
<br /> �LPV225-1U'� 625 1800 1/6 115V/1 P12.4 20 LBS Drawn By: XXX/XXX
<br /> RTU-2 FOH/BOH 8 854 0.18 CFM/SQ. FT. 214 CFM 781 CFM SEE BELOW
<br /> OUTSIDE AIR SCHEDULED ABOVE MINIMUM FOR BUILDING PRESSURIZATION. NOTE: PROVIDE DOOR ACTIVATED SWITCH
<br /> Sheet Number:
<br /> M2 , 1 Q
<br /> m
<br /> M
<br /> V)