Laserfiche WebLink
12"X 12"RECESSED LED LIGHT,4K NATURAL gn <br /> OUTPUT. 1114o <br /> W � T <br /> CV C D <br /> FIELD WRAPPER 18.00"HIGH ` LCD <br /> O a� <br /> T- o o (SEE HOOD OPTIONS TABLE) Fy a) ti C-0111/2" KITCHEN EXHAUST FAN1: CONDITIONED MAKE—UP AIR UNIT1: w `—' x ti <br /> 54" U.L. LISTED DIRECT DRIVE UPBLAST CENTRIFUGAL U.L. LISTED DIRECT DRIVE SUPPLY FAN. 1,710 CFM AT 0.50" W.G. o a <br /> X16 EXHAUST FAN WITH HINGED BASE CONFORMING E.S.P., 1.5 HP, 208V, 3—PHASE. <br /> EXHAUST RISER SUPPLY RISER WITHX <br /> TO NFPA 96. 2,475 CFM AT 1.75" W.G. E.S.P., <br /> U.L.Listed 12"x 12"Recessed LED HANGING ANGLE <br /> VOLUME DAMPER 1.5 HP, 208V, 3—PHASE. CONDITIONED MAKE—UP AIR UNIT2: <br /> 2 3/4" en O Q LL <br /> � <br /> Light U.L. LISTED DIRECT DRIVE SUPPLY FAN. 3,262 CFM AT 0.50" v O <br /> 54" SEE HOOD TA 23.5%OPEN STAINLESS �"� <br /> KITCHEN EXHAUST FAN2: W.G. E.S.P., 2.0 HP, 208V, 3—PHASE. T <br /> STEEL PERFORATED PANEL U.L. LISTED DIRECT DRIVE UPBLAST CENTRIFUGALx <br /> 20"CAPTRATE SOLO o M <br /> O <br /> FILTER WITH HOOK 6" EXHAUST FAN WITH HINGED BASE CONFORMING UNIT SHALL BE EQUIPPED WITH DX COOLING MODULE AND =„ <br /> TO NFPA 96. 1,950 CFM AT 2.0” W.G. E.S.P., MOTORIZED INTAKE DAMPER STANDARD. GAS—FIRED HEATING CO C\J <br /> 3"INTERNAL STANDOFF 24" } 1.5 HP, 208V, 3—PHASE. MODULE SHALL BE INCLUDED FOR RESTAURANTS LOCATED IN O ti <br /> 24"NOM. ASHRAE CLIMATE ZONES 5 THROUGH 7. w M <br /> Utility Utility LED 18" KITCHEN EXHAUST FAN3: `c a' <br /> Cabinet 36" 36" 36" Cabi et IT IS THE RESPONSIBILITY U.L. LISTED DIRECT DRIVE UPBLAST CENTRIFUGAL <br /> OF THE ARCHITECT/OWNER TO EXHAUST FAN WITH HINGED BASE CONFORMING <br /> ___ M ENSURE THAT THE HOOD CLEARANCE TO NFPA 96. 2,138 CFM AT 1.75" W.G. E.S.P., <br /> _ FROM LIMITED-COMBUSTIBLE <br /> e"- -- e" --------- — 1.5 H 208 3—PHASE <br /> _i = I AND COMBUSTIBLE MATERIALS <br /> 24 1 IS IN COMPLIANCE WITH 23" RE: 5M3.1 FOR KITCHEN EXHAUST FAN DETAIL. <br /> Min , <br /> T 5 I 7" „ I 7" 5" LOCAL CODE REQUIREMENTS. <br /> aPW I a" e" SERVICE <br /> a o 0 o J o DIRECT—FIRED MODULE <br /> GREASE DRAIN 48.0"MAX DISCONNECT (IF EQUIPPED) INLET HOOD SECTION WITH Store: <br /> 6" 1 " r22" <br /> WITH REMOVABLE CUP 23"s6' 2z 2z 222 EASY ACCESS FILTER RACK <br /> 1z' 22 22' ' <br /> LEFT AND RIGHT QUARTER END PANELS WITH FILTERS <br /> ss" BACKSPLASH 80.00"HIGH <br /> COIL AIRFLOW 1311 E. YOSEMITE AVE. <br /> X 156.00"LONG <br /> 6" 1 52" � 52" gp" ACCESS AIR LOW � MAKE—UP AIR INLET SHALL <br /> LIGHTING FOR ACPSP Job#4424831 -Hood#1 IRFLOJ DOOR BE 10'-0" MIN. FROM MANTECA CA 95336 <br /> EXHAUST FAN OUTLET OR 7 <br /> 12' s° 52° 52° 12" INPUT: 120V AC, 1 Phase,50/60Hz,3.5 Watts per light. l VENT STACK. <br /> TO CONTROL LIGHTS WITH HOOD LIGHT SWITCH,WIRE PER Restaurant #RC529 <br /> 11'0"Nom./11'0.00"OD HOOD ELECTRICAL CONTROL PANEL SCHEMATIC. <br /> TO CONTROL LIGHTS WITH BUILDING LIGHT SWITCH,WIRE EQUIPMENT ROOF SYSTEM <br /> 13'-0.00"Overall Length BLACK AND WHITE WIRE TO A 120VAC SERVICE. BY OTHERS <br /> PLAN VIEW — Hood #1 (&H-1 ) END TO END ACPSPS REQUIRE 120VAC FIELD WIRING FROM BLOWER/MOTOR NPT GAS CONNECTION Professional of Record: <br /> „ J-BOX TO J-BOX. REPLACE LIGHTS WITH LED LIGHTS ONLY. ACCESS DOOR 1" <br /> 11 ' 0. 00 LONG 5424ND-2—ACPSP—F CURB, WITH BASE24" SERVICE (IF EQUIPPED) <br /> FLANGE SHALL CLEARANCE REQ. <br /> Ll <br /> ACPSP ships loose for field installation MATCH CONTOUR <br /> OF ROOF SYSTEM <br /> AND ROOF PITCH, s% <br /> WALL CANOPY KITCHEN HOOD1 DETAIL SECTION VIEW — MODEL TYP. <br /> 5424ND-2—ACPSP—F ALL SURFACES OF THE FAN PACKAGES (INCLUDING EXHAUST FAN, MAKE—UP <br /> N.T.S. AIR UNIT WITH SUPPORTS, CURB AND CONTROL PANEL) EXPOSED TO VIEW <br /> HOOD — #1 (KH—9) UNITS SHALL BE PROVIDED SHALL HAVE EPDXY FINISH, COLOR SHALL MATCH ROOF SYSTEM. <br /> WITH SEPARATE INDIVIDUAL <br /> 12"X 12"RECESSED LED LIGHT,4K NATURAL CURBS. ROBISON <br /> 39" 39" OUTPUT. <br /> ENGINEERING, INC <br /> FIELD WRAPPER 18.00"HIGH 19401 40TH AVE W.,SUITE 302 <br /> F3,. (SEE HOOD OPTIONS TABLE) HOOD EXHAUST FAN / MAKE-UP AIR UNIT DETAILS LYNNWOOD,WA9EL <br /> sa° 206.3643343 TEL <br /> HANGING ANGLE 41N.T.S. <br /> SUPPLY RISER WIT EXHAUST REI# 424-1497 <br /> e14 VOLUME DAMPE 2 3/4" RISER <br /> 23.5%OPEN STAINLESS SEE 1'.YABLE <br /> STEEL PERFORATED PANEL /�� <br /> " L STANDOFF <br /> 6„ CAPTRATE SOLO <br /> TER WITH HOOK <br /> 54" Oil Passaoab„Zl x„Zl Pals! Tfl <br /> 28" <br /> LED 181, 24"NOM. QRQFESS/0� <br /> D• Rp ql <br /> Z <br /> 0 28" 28" Qo IT IS THE RESPONSIBILITY w M-2871 m <br /> OF THE ARCHITECT/OWNER TO <br /> T ENSURE THAT THE HOOD CLEARANCE EXP 0-21 <br /> FROM LIMITED-COMBUSTIBLE <br /> I I AND COMBUSTIBLE MATERIALSSJ F <br /> MINIMUM 40" <br /> za 9 e„nW LOCAL CODE REQUIS IN IREMENTS.NTS 44. 0"MAX NCE WITH DISCHARGE qTF OF CA��F��� <br /> in a°oo ovn" <br /> HEIGHT FACTORY INSTALLED <br /> 5" 5" <br /> s.. � TOGGLE SWITCH <br /> GREASE DRAIN <br /> 1s° s° I WITH REMOVABLE CUP 78" p <br /> 12" 27" z7" 1z" �O/�T/2� <br /> HINGED SIDE OF FAN <br /> LIGHTING FOR ACPSP Job#4424831 -Hood#2 _--PROVIDE U.L. TYPE LA Prototype: P4 EXTENDED- HV, SCHEME A <br /> 191/2" 39" INPUT: 120V AC, 1 Phase,50/60Hz,3.5 Watts per light. EQUIPMENT LIQUID TIGHT FLEXIBLE <br /> TO CONTROL LIGHTS WITH HOOD LIGHT SWITCH,WIRE PER BY OTHERS METALLIC CONDUIT AND Prototype Issue Date: 6.29.2020 <br /> -19,/2" 39" HOOD ELECTRICAL CONTROL PANEL SCHEMATIC. CONNECTOR. PROVIDE <br /> 6'6"Nom./6'6.00"OD TO CONTROL LIGHTS WITH BUILDING LIGHT SWITCH,WIRE ADEQUATE LENGTH TO Design Bulletin Updates: INCLUDED <br /> BLACK AND WHITE WIRE TO A 120VAC SERVICE. <br /> PLAN VIEW — Hood #2 (KH-2) END TO END ACPSPS REQUIRE 120VAC FIELD WIRING FROM ALLOW FAN TO HINGE <br /> 6' 6. 00" LONG 5424ND-2WI—ACPSP—F ° <br /> J-BOX TO J-BOX. REPLACE LIGHTS WITH LED LIGHTS ONLY. I� OPEN FOR CLEANING. Date Issued: Bulletin Number: <br /> y <br /> GREASENOV. 2018 1 & 2 <br /> ACPSP ships loose for field installation SECTION VIEW — MODEL COLLECTION CONNECTOR CURBAS EXTENSION, <br /> SYSTWALL CANOPY KITCHEN HOOD2 DETAIL BLE <br /> 5424ND-2WI—ACPSP—F FMOUNT TO IXED CURB 1ST BLDG. SUBMITTAL <br /> 1"LAYER OF INSULATION 21N.T.S. HOOD — #2 (&H—J2 z NEMA 3R JUNCTION BOX <br /> FACTORY INSTALLED IN 12"X 12"RECESSED LED LIGHT,4K NATURAL GASKETED BUSHING <br /> 1.00"END STANDOFF MEETS OUTPUT. WELDED EXHAUST <br /> DUCT FOR WATERTIGHT SEAL <br /> 0"REQUIREMENTS CLEARANCE TOP OF <br /> ACES. <br /> TO COMBUSTIBLE SURFFIELD WRAPPER 18.00"HIGH ROOF <br /> (SEE HOOD OPTIONS TABLE) <br /> o FLASHING AND <br /> 54" COUNTER— FLASHING <br /> 014' J INTO ROOF DECK, <br /> EXHAUST RISER SUPPLY RISER WITH <br /> TYPICAL <br /> HANGING ANGLE VOLUME DAMPER ROOF DECK <br /> 2 3/4° � REVISIONS: <br /> U.L.Listed 12"x 12"Recessed LED SEE HOOD TA 23.5%OPEN STAINLESS FIRE RATED DUCT WRAP <br /> 54" <br /> Light STEEL PERFORATED PANEL EXTENDED TO TOP OF ROOF CONDUIT BY ELECTRICAL 1 08-07-20 1st. Bldg. Submittal <br /> 20"CAPTRATE SOLO 6„ CURB <br /> FILTER WITH HOOK 2 <br /> 3"INTERNAL STANDOFF 24" f KITCHEN HOOD EXHAUST FAN DETAIL 3 <br /> 24"NOM. <br /> LEDN.T.S. <br /> 18" 51 4 <br /> Utility IT IS THE RESPONSIBILITY 5 <br /> 28" 28" 28" t OF THE ARCHITECT/OWNER TO 6 <br /> o ENSURE THAT THE HOOD CLEARANCE <br /> ;= ®o FROM LIMITED-COMBUSTIBLE-X7 <br /> AND COMBUSTIBLE MATERIALS <br /> 101, IS IN COMPLIANCE WITH 23" <br /> 24" J— J— LOCAL CODE REQUIREMENTS. 9 <br /> ac......i <br /> U, 7., <br /> Hv �z 6' 5" <br /> o® 5 ®o 48.0"MAX <br /> GREASE DRAIN <br /> WITH REMOVABLE CUP 23" <br /> za 28' LEFT AND RIGHT QUARTER END PANELS <br /> 12" 253/4° 253/4" 253/4" 253/4° 12' BACKSPLASH 80.00"HIGH Sheet Title: <br /> sr' s7° X127.00"LONG KITCHEN HOOD DETAILS <br /> LIGHTING FOR ACPSP Job#4424831 -Hood#3 80" <br /> INPUT: 120V AC, 1 Phase,50/60Hz,3.5 Watts per light. <br /> z,1/a° 42 1/4" 42 1/4" TO CONTROL LIGHTS WITH HOOD LIGHT SWITCH,WIRE PER AND HVAC SPECS. <br /> z" HOOD ELECTRICAL CONTROL PANEL SCHEMATIC. <br /> 31 3/4" 631/2' TO CONTROL LIGHTS WITH BUILDING LIGHT SWITCH,WIRE <br /> 9'6"Nom./9'6.00"OD BLACK AND WHITE WIRE TO A 120VAC SERVICE. EQUIPMENT <br /> END TO END ACPSPS REQUIRE 120VAC FIELD WIRING FROM Date: 08.07.2020 <br /> 10'-7.00"Overall Length J-BOX TO J-BOX.REPLACE LIGHTS WITH LED LIGHTS ONLY. BY OTHERS <br /> PLAN VIEW — Hood #3 (&H—J3 Project Number: RAC19024.0 <br /> 9' 6. 00" LONG 5424ND-2—ACPSP—F Drawn By: XX)(/XXX <br /> ACPSP ships loose for field installation <br /> SECTION VIEW — MODEL <br /> 3 WALL CANOPY KITCHEN HOODS DETAIL 5424ND-2—ACPSP—F Sheet Number: <br /> N.T.S. HOOD — #3 (ME-31 � <br /> M3 , 1 Q <br /> m <br /> V) <br />