Laserfiche WebLink
2 FIRE ALARM RISER DIAGRAM ELECTRICAL SPECIFICATIONS <br /> 33 THE ELECTRICAL CONTRACTOR SHALL FURNISH AND INSTALL, COMPLETE AND READY FOR 33.22 FIRE ALARM CIRCUITS SHALL BE IDENTIFIED AT TERMINAL AND JUNCTION LOCATIONS, IN A H <br /> OPERATION, A HARDWIRED, SUPERVISED, ZONED AUTOMATIC FIRE AND SMOKE DETECTION MANNER THAT WILL PREVENT UNINTENTIONAL INTERFERENCE WITH THE SIGNALING CIRCUIT <br /> SYSTEM INCLUDING A CENTRAL CONTROL PANEL, DETECTION AND ALARM INITIATING DEVICES, DURING TESTING AND SERVICING. W o <br /> 2 D RELAYS, WIRING, ALL IN ACCORDANCE WITH THE DRAWINGS AND APPLICABLE STANDARDS. N <br /> COMPLY WITH NEC 760 (2008), NFPA 72 (2007) AND 90A (2002), AND ALL FEDERAL, 33.21 WIRING TO BE AS HEREINBEFORE SPECIFIED AND BE COPPER, 300 VOLT RATING. AUDIO x o 0-) <br /> 1-1/4"C AND WIRE STATE AND LOCAL LAWS AND ORDINANCES, INCLUDING THE AMERICANS WITH DISABILITIES VISUAL APPLIANCE WIRING TO BE PVC JACKETED, 16 AWG MINIMUM SIZE, NUMBER OF �..� CD <br /> AS REQUIRED ACT. THE ELECTRICAL CONTRACTOR SHALL VERIFY THAT THE COMPLETED SYSTEM CONDUCTORS REQUIRED. SUBMIT CALCULATIONS ON LOAD AND VOLTAGE DROP. INITIATING w x <br /> OPERATES IN ACCORDANCE WITH THIS SPECIFICATION. SYSTEMS SHALL BE U.L. AND/OR DEVICE WIRING TO BE PVC JACKETED, 18 AWG MINIMUM SIZE. SUBMIT CALCULATIONS ON o <br /> F.M. LISTED AND APPROVED. LOAD AND VOLTAGE DROP. VOICE EVACUATION SPEAKER WIRING TO BE PVC JACKETED, 16 x o � x <br /> _ <br /> FIRE ALARM CABLE IN CONDUIT AWG MINIMUM SIZE. SUBMIT CALCULATIONS ON LOAD AND VOLTAGE DROP. W Q <br /> TO TELEPHONE BACKBOARD FOR 33.1 WHERE SHOWN ON THE DRAWINGS OR REQUIRED BY REGULATORY CODES PROVIDE A ' C o <br /> 2 DEDICATED PHONE LINES. FAP DACT TO HOOD SUPPRESSION RAP 33.24 CONTROLLED OUTPUT DEVICES SHALL BE SUPERVISED TO WITHIN THREE FEET OF THE w o 0 <br /> ( ) / DIGITALLY DERIVED AUTO DIALER SYSTEM TO AUTOMATICALLY SEIZE A DEDICATED <br /> MAKE CONNECTION TO DACT. SYSTEM CONTROL PANEL 0-- <br /> TELEPHONE LINE TO DIAL AND SIGNAL AN ALARM TO A REMOTE LOCATION. DEVICE CONTROLLED (AIR UNIT STARTER, KITCHEN HOOD, ETC.). �: Q <br /> o o� <br /> TO SPRINKLER HEAT TRACE TO AIR UNIT SHUT DOWN 33.2 THE ELECTRICAL CONTRACTOR SHALL ENGAGE A FIRE DETECTION SYSTEM CONTRACTOR AS 33.25 WHERE A FIRE DETECTION SYSTEM AS SPECIFIED HEREIN AND REQUIRED FIRE PROTECTION <br /> CONTROLLER A SUBCONTRACTOR TO COORDINATE THE INSTALLATION OF THE WORK AND PROVIDE SHOP SPRINKLER SYSTEM ARE INSTALLED, IT SHALL BE PART OF THIS FIRE DETECTION SYSTEM °� N <br /> TO BACKFLOW PREVENTER o ~ <br /> DRAWINGS FOR REVIEW. SHOP DRAWINGS MUST BE SUBMITTEDAPPROVED AND CLEARED CONTRACTOR'S WORK TO NOTIFY IN WRITING THE OWNER OF THE FACILITY OR THE OWNER'S o �0"),TAMPER SWITCHES AND HEAT co <br /> TO POST INDICATOR VALVE FROM THE FIRE MARSHAL'S OFFICE BEFORE ANY WORK IS PERFORMED. THE CONTRACTOR REPRESENTATIVE THAT THE FIRE PROTECTION SYSTEM MUST, BY APPLICABLE CODES, BE <br /> CO <br /> CONTACTS CD <br /> TRACE CONTROL VOLTAGE. WILL BE SOLELY RESPONSIBLE FOR ANY WORK PERFORMED BEFORE FINAL FIRE MARSHAL ADEQUATELY SUPERVISED BY A RESPONSIBLE AUTHORITY APPROVED SUPERVISORY COMPANYCD <br /> MONITOR VOLTAGE ON THE APPROVAL. THAT WILL PROVIDE THE CONTINUOUS MONITORING OF THE SYSTEM TO ASSURE RELIABLE <br /> LOAD SIDE OF THE OPERATION. INSTRUCTIONS SHALL INCLUDE ADVISING THE OWNER TO WRITE THE INSPECTING <br /> DISCONNECT. 33.3 THE MAIN CONTROL PANEL SHALL BE RECESSED MOUNTED AND SHALL BE LISTED BY AUTHORITY ADVISING OF THIS COMPLIANCE. <br /> UNDERWRITERS' LABORATORIES, INC. FOR FIRE PROTECTIVE SIGNALING SYSTEMS. THE MAIN <br /> CONTROL PANEL SHALL CONTAIN THE PROPER NUMBER OF ZONES AND ZONE MODULES TO <br /> PROVIDE FOR THE NUMBER OF ZONES SHOWN ON THE DRAWINGS AND SPECIFIED HEREIN, <br /> FLOOR INCLUDING SPACE CAPABILITY FOR FUTURE. PROVIDE 3 EACH 3/4" EMPTY CONDUIT IN <br /> WALL TO THE ACCESSIBLE CEILING SPACE. MAKE OF MODEL SHALL BE HONEYWELL/ES-50X Store: <br /> FIRE ALARM PANEL AND SHALL BE PROVIDED BY CONTRACTOR. <br /> 33.4 WHERE THE MAIN CONTROL PANEL WILL INITIATE AN EMERGENCY FORCES NOTIFICATION 1311 E. YOSEMITE AVE. <br /> PROCEDURE, THE CONTRACTOR SHALL SHOW THE U.L. LISTING FOR THE CONTROL PANEL MANTECA, CA 95336 <br /> FOR THIS FUNCTION. <br /> 33.5 THE REQUIRED SECONDARY POWER SOURCE SHALL BE PROVIDED FOR BY A U.L. LISTED Restaurant #RC529 <br /> POWER SUPPLY, CHARGER AND BATTERY SYSTEM. THE SYSTEM SHALL BE SIZED FOR ALL <br /> ZONES CONNECTED PLUS THE ZONE CAPABILITY OF THE SYSTEM, AND AN ADDITIONAL 30% <br /> SAFETY FACTOR. <br /> Professional of Record: NAME <br /> 33.6 THE REMOTE INDICATING PANEL SHALL SHOW ALL VISUAL AND AUDIBLE TROUBLE SIGNALS <br /> AND ZONE INDICATORS THE SAME AS THE MAIN CONTROL PANEL BUT WILL NOT HAVE THE <br /> RESET FUNCTION. REMOTE PANEL SHALL BE FOR RECESSED MOUNTING. <br /> 33.7 PROVIDE A SOLID STATE ACTIVE SURGE PROTECTOR FOR THE INCOMING 120V A.C. LINE. <br /> UNIT TO CLAMP SPIKES AND PEAKS TO A LEVEL BELOW THE DAMAGE THRESHOLD OF THE <br /> UNIT. UNIT TO HAVE OPERATING LIGHT TO INDICATE PROTECTION. SYSTEM TO BE U.L. <br /> LISTED FOR FIRE PROTECTION SYSTEM APPLICATION. <br /> 33.8 THE CONTROL PANEL SHALL PROVIDE POWER FOR AND RECEIVE THE INPUT INITIATION FROM <br /> INSTALLED SMOKE DETECTORS. DETECTORS SHALL BE U.L. LISTED FOR THE APPLICATION ROBISON <br /> AND BE COMPATIBLE LISTED WITH THE MAIN CONTROL PANEL. <br /> 33.9 DO NOT LOCATE SMOKE DETECTORS WITHIN THREE FEET OF ANY SUPPLY OR RETURN AIR ENGINEERING, INC <br /> GRILLE OR DIFFUSER. UNIT SHALL BE CAPABLE OF OPERATING IN AIR CURRENTS OF UP TO 19401/OTF AVE W..SUITE 3C2 <br /> 1500 FEET PER MINUTE. v <br /> LYNNWOOD,WA 98036 <br /> 206-3643343 TE_ <br /> 33.10 DETECTORS MOUNTED IN SUPPLY, RETURN OR EXHAUST AIR DUCTS SHALL BE UL LISTED <br /> FOR DUCT SERVICE UTILIZING AIR SAMPLING TUBES, LENGTH OF THE TUBE THE FULL WIDTH REI# 424-1497 <br /> OF THE DUCT. THIS DETECTOR SHALL BE PHOTOELECTRIC TYPE, LOW FLOW TYPE WITH A <br /> RANGE OF 100 TO 4,000 FEET PER MINUTE. DETECTOR SHALL BE UL COMPATIBLE WITH <br /> THE CONTROL PANEL AND UL LISTED FOR DUCT MOUNTING. <br /> 33.11 DUCT DETECTORS SHALL HAVE SUPERVISED AUXILIARY CONTACTS FOR USE IN THE <br /> INTERLOCK AND SHUT DOWN CONTROL SCHEMES AS REQUIRED BY THIS SECTION AND THE <br /> MECHANICAL SECTIONS OF THIS SPECIFICATION. <br /> 33.12 PROVIDE AS PART OF THE MAIN CONTROL PANEL AN AUTO TELEPHONE NUMBER DIALER QROFESS/ON,9 <br /> SYSTEM. THE DIALER SYSTEM IS TO ACTIVATE UPON THE FIRE DETECTION SYSTEM ALARM <br /> AND WILL HAVE AN OUTPUT DIALER NUMBER SUCH THAT A DEDICATED NUMBER CAN BE C/) <br /> DIALED AND GIVEN SEPARATE DIGITAL ALARM SEQUENCES. SYSTEM MUST BE A DACT AND `9 Z <br /> BE U.L. LISTED FOR THIS APPLICATION. MAKE OF MODEL SHAKL BE TELGUARD TG-7FS AND cD o. E-23059 m <br /> SHALL BE PROVIDED BY CONTRACTOR. <br /> � <br /> 33.13 AUTO—DIALER SHALL BE CONNECTED WITH TWO TELEPHONE LINES USING FIRE ALARM RATED EXP. 3—al-22 <br /> CABLE. CATEGORY RATED CABLE IS NOT ACCEPTABLE. QFC \ <br /> 33.14 PROVIDE A DEDICATED SOURCE OF POWER FOR THE SYSTEM AS PER NFPA 72. THE q�F CA\\F�� <br /> CIRCUIT SHALL BE DEDICATED TO ONLY THIS SERVICE AND CONNECTIONS SHALL BE <br /> MECHANICALLY PROTECTED. THE CIRCUIT DISCONNECTING MEANS SHALL HAVE A RED <br /> MARKING, BE ACCESSIBLE ONLY TO AUTHORIZED PERSONNEL, AND BE IDENTIFIED AS "FIRE <br /> ALARM CIRCUIT CONTROL." THE LOCATION OF THE CIRCUIT DISCONNECTING MEANS SHALL 08/07/20 <br /> BE PERMANENTLY IDENTIFIED AT THE FIRE ALARM CONTROL PANEL WITH AN ENGRAVED <br /> LABEL. <br /> Prototype : P4 EXTENDED- HV. SCHEME A <br /> 33.15 THE ELECTRICAL CONTRACTOR SHALL PROVIDE ALL CONDUIT, WIRING AND CONNECTIONS TO <br /> ALL EQUIPMENT BEFORE CALLING THE UNIT MANUFACTURER'S REPRESENTATIVE FOR FINAL Prototype Issue Date: 6 29 2020 <br /> CHECKOUT. ALL WIRING IS TO BE INSTALLED IN A SEPARATE CONDUIT SYSTEM, AS PER <br /> OTHER SECTIONS OF THIS SPECIFICATION, UNLESS SPECIFICALLY NOTED OTHERWISE. Design Bulletin Updates: INCLUDED <br /> 33.16 ALL SPLICES AND CONNECTIONS TO BE WHOLLY CONTAINED WITHIN APPROVED AND Date Issued: Bulletin Number: <br /> ACCESSIBLE JUNCTION BOXES. ALL INPUT INITIATING DEVICES AND OUTPUT SIGNALING <br /> APPLIANCES ARE TO BE MOUNTED WITH BACK BOXES AS PER THE U.L. TESTING PROCEDURE NOV. 2018 1 &2 <br /> FOR THAT DEVICE. NO DIRECT MOUNTED DEVICES ARE ALLOWED. HARDWIRED SYSTEMS p <br /> SHALL NOT BE "T—TAPPED" TO SERVE INPUT INITIATING OR OUTPUT NOTIFICATION DEVICES. 1St Building Submittal <br /> 33.17 THE SYSTEM SHALL BE ZONED AS PER DRAWINGS; INCLUDE A SEPARATE ZONE FOR EACH <br /> FIRE PROTECTION ALARM SYSTEM FLOW SWITCH, AS APPLICABLE. REFER TO THE <br /> MECHANICAL SPECIFICATIONS AND DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE <br /> FIRE DETECTION SYSTEM CONTRACTOR TO PROVIDE ALL COMPONENTS NECESSARY TO TIE <br /> INTO THE SYSTEMS PROVIDED BY OTHERS. THE ELECTRICAL CONTRACTOR SHALL ALSO <br /> PROVIDE ALL WIRING AS REQUIRED INCLUDING ALL ACCESSORIES DEMANDED BY THE WIRING <br /> SYSTEM FOR THE FIRE PROTECTION SYSTEM COVERED UNDER THE MECHANICAL <br /> SPECIFICATIONS. <br /> 33.18 USE RED COLORED MULTI CONDUCTOR FIRE PROTECTIVE SIGNALING CIRCUIT CABLES. THE <br /> CABLE MARKING SHALL BE IN ACCORDANCE WITH TABLE 760 179 (I) OF THE NEC. THIS <br /> CABLE SHALL BE USED FOR ALL INITIATING AND SIGNALING WORK AND FOR THE TELEPHONE REVISIONS: <br /> LINES FOR ANY DACT UNITS IN THE SYSTEM. CONDUCTORS SHALL BE INSTALLED IN <br /> ACCORDANCE WITH ARTICLE 760 OF THE NEC. CABLES THAT ARE INSTALLED WITH 1 08-07-20 1st. Bldg. Submittal <br /> PORTIONS IN CONDUIT UNDERGROUND OR UNDER SLAB SHALL BE NEC RATED FOR WET 2 <br /> LOCATIONS. SUCH CABLES SHALL BE GEL FILLED OR WATER BLOCKED CONSTRUCTION AND <br /> SHALL HAVE THE FULL LENGTH INSTALLED IN CONDUIT. CABLE SHALL BE BELDEN 3 <br /> WATERDOG SERIES, WEST PENN AQUASEAL SERIES OR EQUAL AS LISTED BY ADDENDA. 4 <br /> SUBMIT ALL CABLES FOR REVIEW WITH THE SHOP DRAWINGS. <br /> 5 <br /> 33.19 FIRE ALARM CIRCUITS SHALL BE INSTALLED IN A NEAT AND WORKMANLIKE MANNER. CABLES 6 <br /> SHALL BE SUPPORTED BY THE BUILDING STRUCTURE IN SUCH A MANNER THAT THE CABLE 7 <br /> WILL NOT BE DAMAGED BY NORMAL BUILDING USE. <br /> 8 <br /> 33.20 ALL WIRING SHALL BE INSTALLED IN A SEPARATE CONDUIT SYSTEM FROM ALL OTHER 9 <br /> SYSTEMS. WIRING INSIDE WALLS AND INSTALLED IN INACCESSIBLE CEILING SPACES TO BE IN <br /> CONDUIT. WIRING INSTALLED IN ACCESSIBLE CEILINGS MAY BE ROUTED WITHOUT CONDUIT. <br /> ROUTE ALL CABLES PARALLEL OR PERPENDICULAR TO WALLS. DO NOT RUN IN A DIAGONAL <br /> FASHION. <br /> 33.21 WIRING WITHOUT CONDUIT SHALL USE DEDICATED J HOOKS MOUNTED AT 4'-0" MAXIMUM Sheet Title: <br /> APART. DO NOT ROUTE FIRE ALARM CABLES BUNDLED WITH ANY OTHER CABLING. DO NOT ELECTRICAL <br /> STRAP TO CONDUIT. USE B—LINE BCH SERIES OR CADDY CAT SERIES J—HOOKS WITH <br /> MOUNTING AS APPROPRIATE TO THE LOCATION. DO NOT USE NYLON OR PLASTIC STRAPS. SPECIFICATIONS <br /> DO NOT FASTEN TO CONDUIT OR TO ANY MECHANICAL OR OTHER MOVING EQUIPMENT. <br /> MOUNT ALL SYSTEMS AS HIGH AS POSSIBLE AND ROUTED SO AS TO AVOID ACCESS POINTS <br /> TO OTHER EQUIPMENT AND PERMIT SERVICING. DO NOT ATTACH TO HANGERS USED FOR <br /> CEILING SYSTEMS, LIGHTING FIXTURES, HVAC DUCTWORK, ETC. Date: 08 07 2020 <br /> Project Number: RAC19024.0 <br /> Drawn By: XXX/XXX <br /> Sheet Number: <br /> E4 . 2 <br /> J <br /> Q <br /> H <br /> CH <br /> L <br /> m <br /> COPYRIGHT 2020, ROBISON ENGINEERING, INC. <br /> JESCALONA F:\3EDRO+MCCRACKEN\JRAISING CANES\424-1497 MANTECA, CA\DWG\E42P4.DWG 07-22-2020 15:54 <br />