My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
SU0014339
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
M
>
MAIN
>
4860
>
2600 - Land Use Program
>
PA-2100170
>
SU0014339
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/5/2023 8:44:55 AM
Creation date
8/20/2021 9:47:12 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2600 - Land Use Program
RECORD_ID
SU0014339
PE
2632
FACILITY_NAME
PA-2100170
STREET_NUMBER
4860
Direction
E
STREET_NAME
MAIN
STREET_TYPE
ST
City
STOCKTON
Zip
95215-
APN
17321014
ENTERED_DATE
8/10/2021 12:00:00 AM
SITE_LOCATION
4860 E MAIN ST
RECEIVED_DATE
3/3/2023 12:00:00 AM
P_LOCATION
99
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\gmartinez
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
95
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
as may be applicable. Plans for the different buildings or structures may be combined into a <br /> single set of construction documents. (Please visit https://www.sigov.org/commdev for building <br /> permit check list(s) and application forms.) <br /> 2. A grading permit will be required for this project. Submit plans and grading calculations, <br /> including a statement of the estimated quantities of excavation and fill, prepared by a <br /> Registered Design Professional. The grading plan shall show the existing grade and finished <br /> grade in contour intervals of sufficient clarity to indicate the nature and extent of the work and <br /> show in detail that it complies with the requirements of the code. The plans shall show the <br /> existing grade on adjoining properties in sufficient detail to identify how grade changes will <br /> conform to the requirements of the code. <br /> 3. A soils report is required pursuant to CBC §1803 for foundations and CBC appendix §J104 for <br /> grading. All recommendations of the Soils Report shall be incorporated into the construction <br /> drawings. <br /> 4. For each proposed new building, provide the following information on the plans: <br /> A. Description of proposed use <br /> B. Existing and proposed occupancy Groups <br /> C. Type of construction <br /> D. Sprinklers (Yes or No) <br /> E. Number of stories <br /> F. Building height <br /> G. Allowable floor area <br /> H. Proposed floor area <br /> i. Occupant load based on the CBC <br /> J. Occupant load basedonthe CPC <br /> 5. If high-piled combustible storage is to be used in a building, an automatic fire sprinkler system <br /> will-be required. <br /> 6. At least one (1) accessible route shall be provided within the site from accessible parking <br /> spaces and accessible passenger loading zones; public streets and sidewalks; and public <br /> transportation stops to the accessible building or facility entrance they serve. Where more than <br /> one (1) route is provided, all routes must be accessible. §11 B-206.2.1 <br /> 7. At least one (1) accessible route shall connect accessible buildings, accessible facilities, <br /> accessible elements, and accessible spaces that are on the same site. §11 B-206.2.2 <br /> 8. At least one (1) accessible route shall connect accessible building or facility entrances with all <br /> accessible spaces and elements within the-building or facility, including mezzanines,which are <br /> otherwise connected by a circulation path. §11 B-206.2.4 <br /> 9. Parking spaces will be required to accommodate persons with disabilities in compliance with <br /> Chapter 11 B of the California Building Code. Note that accessible parking spaces are required <br /> for each phase of the project. These parking space(s) shall be located as close as possible to <br /> the primary entrance to the building. <br /> 10. Adequate sanitary facilities shall be provided for the facility, per the requirements of Chapter 4 <br /> of the California Plumbing Code. <br /> 11. Pursuant to Section 422.4 of the California Plumbing Code, toilet facilities shall be accessible <br /> to employees at all times,should not be more than 500 feet from where employees are regularly <br /> employed and accessible by not more than one flight of stairs. The plans shall indicate the <br /> location of the toilet facilities and the travel distance from work areas. <br /> Administrative Use Permit No. PA-2100170—Conditions of Approval 3 <br />
The URL can be used to link to this page
Your browser does not support the video tag.