Laserfiche WebLink
S A N J 0 A Q I I I Irl Environmental Health Department <br /> CCUNT <br /> Aboveground Petroleum Storage Act Inspection Report <br /> Facility Name: Facility Address: Date: <br /> ESCALON UNIFIED SCHOOL DIST 1 1176 STANISLAUS ST, ESCALON August 06, 2021 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 623 CFR 112.7(f)(3) Failure to conduct complete annual discharge prevention briefings for oil-handling personnel. <br /> OBSERVATION: Failure to conduct spill prevention briefing for oil-handling personnel at least once a year to assure <br /> adequate understanding of the SPCC Plan, including: 1. Known discharges or failures. 2. Malfunctioning <br /> components. 3.Any recently developed precautionary measures. <br /> REGULATION GUIDANCE: (f)(3)Schedule and conduct discharge prevention briefings for your oil-handling <br /> personnel at least once a year to assure adequate understanding of the SPCC Plan for that facility. Such briefings <br /> must highlight and describe known discharges as described in§ 112.1(b)or failures, malfunctioning components, <br /> and any recently developed precautionary measures. <br /> CORRECTIVE ACTION: Discharge prevention briefings for oil handling personnel must be scheduled and <br /> conducted at least once a year to assure adequate understanding of the SPCC Plan for that facility. Conduct all <br /> required spill prevention briefings. Provide compliance verification to the EHD. <br /> This is a repeat violation, Class II. <br /> 706 CFR 112.8(c)(2)Failed to provide and maintain adequate secondary containment for bulk storage tanks. <br /> OBSERVATION: The facility failed to provide and maintain secondary containment for bulk storage tank installations <br /> sufficient to hold the capacity of the largest container, including adequate freeboard for precipitation. <br /> -The 10,000 gallon diesel tank was observed with insufficient secondary containment. In the floor of the dike in the <br /> southwest corner there is a hole with a pipe in it. <br /> -Secondary containment for the used oil, motor oil,gasoline and transmission oil tanks was not discussed in the <br /> SPCC plan. The 1,000 gasoline tank was partially addressed with the oil water separator but portions of the tank <br /> are over soil that does not slope towards the oil water separator. <br /> REGULATION GUIDANCE: (c)(2)Construct all bulk storage tank installations(except mobile refuelers and other <br /> non-transportation-related tank trucks)so that you provide a secondary means of containment for the entire capacity <br /> of the largest single container and sufficient freeboard to contain precipitation.You must ensure that diked areas are <br /> sufficiently impervious to contain discharged oil. Dikes, containment curbs, and pits are commonly employed for this <br /> purpose.You may also use an alternative system consisting of a drainage trench enclosure that must be arranged <br /> so that any discharge will terminate and be safely confined in a facility catchment basin or holding pond. <br /> CORRECTIVE ACTION: Immediately provide and maintain adequate secondary containment for the following bulk <br /> storage tanks: 10,000 gallon diesel tank. Submit proof of correction to the EHD. <br /> This is a repeat violation, Class II. <br /> FA0003822 PR0528253 SCO01 08/06/2021 <br /> EHD 28-01 Rev.9/16/2020 Page 8 of 11 Aboveground Petroleum Storage Act OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjgov.org/EHD <br />