My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
CORRESPONDENCE_2010-2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
A
>
ACACIA
>
525
>
4500 - Medical Waste Program
>
PR0450001
>
CORRESPONDENCE_2010-2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/19/2023 3:57:50 PM
Creation date
8/27/2021 2:10:56 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
4500 - Medical Waste Program
File Section
CORRESPONDENCE
FileName_PostFix
2010-2019
RECORD_ID
PR0450001
PE
4522
FACILITY_ID
FA0002864
FACILITY_NAME
DAMERON HOSPITAL
STREET_NUMBER
525
Direction
W
STREET_NAME
ACACIA
STREET_TYPE
ST
City
STOCKTON
Zip
95203
APN
13715304
CURRENT_STATUS
01
SITE_LOCATION
525 W ACACIA ST
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\cfield
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
156
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SanI-�,ak Operation Procedure Page 3 of 4 <br />wheel to the right to secure. The hatch wheel should be turned until it is hand tight. <br />CAUTION: Never use more than normal hand force when opening or closing sterilizer <br />load door. Leverage aids such as bars or pipes will overstress mechanism and should <br />EVER be used. <br />44. On the computer pad press the "Start Cycle" button. Then enter your operating code <br />ad push the "Enter" button. The sterilizer will then start the cycle. The red sterilizer light <br />will be lit along with a red indicator light on the sterilizer door. Hatch wheel will <br />automatically lock once the sterilization cycle has been initiated. <br />15. The sterilizer computer will take control of the sterilization process. The computer will <br />automatically monitor the process for proper temperature, vacuum and length of cycle <br />time. If at any time this process should be interrupted by a loss of temperature, vacuum or <br />cycle time, the unit will abort the sterilization process. It will not allow the operator to open <br />the sterilizer door and the Sterilizer Discharge indicator will NOT be showing a blue light, <br />thus indicating that the load was not properly sterilized. The computer will need to be reset <br />and the unit checked for mechanical problems for the cause of the interruption. Once <br />orrected, then the sterilization process can be started again with the SAME load. <br />16. A computer read-out on the sterilization process will be checked against the cycle read- <br />out on a weekly basis to assure that every load is properly sterilized. Disruptions in the <br />sterilization process will be noted in the San -I -Pak Cycle Inspection Log with explanations <br />as to how those disruptions were handled to assure proper sterilization. <br />17. Temperature calibration of the sterilizer will be done once per year. <br />18. The cycle read-out paper roll will be replaced as needed. <br />19. The following documents will be kept in the EVS office by the EVS Manager for a <br />minimum of three years: <br />-calibration checks <br />-cycle read-out <br />-computer read-out <br />-San-I-Pak cycle inspection logs <br />References- <br />None <br />Cross References: <br />None <br />Approvals: <br />Director, Environmental Services: 2/12/2008 <br />Policy Committee: 3/19/2008 <br />Infection Control Committee: 4/14/2008 <br />Environment of Care Committee:4/24/2008 <br />Board of Directors: 5/20/08 <br />Attachments: <br />None <br />History <br />Effective date - 10/92 <br />http://172.16.0.5/policy/policy.nsf/7dbOebfd3e2l O600872571470079e3a4l4bb8f84767ae l f196882573ec006... 4/13/2010 <br />
The URL can be used to link to this page
Your browser does not support the video tag.