My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_PRE 2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
R
>
ROTH
>
116
>
2300 - Underground Storage Tank Program
>
PR0523684
>
COMPLIANCE INFO_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/1/2023 2:59:02 PM
Creation date
9/10/2021 4:32:19 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
PRE 2019
RECORD_ID
PR0523684
PE
2351
FACILITY_ID
FA0015977
FACILITY_NAME
Fast Lane Central Valley
STREET_NUMBER
116
STREET_NAME
ROTH
STREET_TYPE
Rd
City
Lathrop
Zip
95330
APN
196-02-020
CURRENT_STATUS
01
SITE_LOCATION
116 Roth Rd
P_LOCATION
07
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
418
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
San Joaquin County17 <br />Environmental Health Department <br />1868 East Hazelton Avenue, Stockton, California 95205-6232 <br />Telephone: (209) 468-3420 Fax: (209) 468-3433 Web: www.sj og v.or /c/ehd <br />Underground Storage Tank Program Inspection Report <br />Facility Name: <br />Fast Lane Central Valley <br />Facility Address: <br />116 Roth Rd, Lathrop <br />Date: <br />August 08, 2016 <br />SUMMARY OF VIOLATIONS <br />(CLASS I, CLASS II, or MINOR - Notice to Comply) <br />Item # <br />Remarks <br />313 <br />HSC 25290.1, 25290.2, 25291 Failure to construct, operate, and maintain primary containment as product -tight. <br />Approximately one cup of liquid was found in the south diesel spill container on the truck side of the facility and <br />approximately two cups of liquid were found in the diesel spill container on the auto side of the facility. Spill <br />containers shall be constructed to prevent any liquid retention. Note that fuel was found in the south diesel spill <br />container during the inspection on June 17, 2016. Immediately contact a properly licensed, trained, and certified <br />contractor to address the retention of liquid in the spill containers under permit and inspection of the Environmental <br />Health Department. <br />This is a repeat violation, Class Il. <br />316 <br />HSC 25290.1(c3), 25290.2(c3) Secondary containment not constructed to prevent water intrusion (after Jul 2003). <br />Water was found in the diesel north submersible turbine pump (STP) sump, diesel south STP sump, under dispenser <br />containment (UDC) sumps for UDC 13/14B, UDC 14A/15B, UDC 15A/16B, UDC 16A/17B, UDC 17A/18B, and UDC <br />18A/19 on the truck side of the facility. Secondary containment shall be constructed to prevent any water intrusion <br />into the system by precipitation, infiltration, or surface runoff. The service technician removed approximately: <br />one-half cup of liquid from UDC 13/14B, one cup of liquid from UDC 14A/15B, one-half cup of liquid from UDC <br />15A/16B, one -and -a -half cups of liquid from UDC 16A/17B, one cup of liquid from UDC 17A/18B and one cup of <br />liquid from UDC 18A/19 and returned the sensors to their proper locations. Note that liquid was found in UDCs: <br />13/148, 16A/17B, 17A/18B and 18A/19 during the inspection on June 17, 2016. Immediately contact a properly <br />licensed, trained, and certified contractor to address the water intrusion into the STP and UDC sumps under permit <br />and inspection of the Environmental Health Department. <br />This is a repeat violation, Class II. <br />318 <br />CCR 2636(f)(2) Leak detector failed to detect a 3.0 gph leak at 10 psi. <br />The south diesel (D1) underground storage tank VMI line leak detector on the truck side of the facility failed to detect <br />a leak when tested on 8/8/2016. The service technician stated that a new siphon jet valve had been installed on <br />6/16/2016. All line leak detectors shall be capable of detecting a 3 -gallon per hour leak at 10 psi. The service <br />technician adjusted the leak detector, retested it, and it passed. <br />This was corrected on site. <br />This is a repeat violation, Class II. <br />319 <br />CCR 2635(b) No spill bucket, failed to contain five gallons, or failed to provide a means to keep it empty. <br />Approximately one cup of liquid was found in the south diesel spill container on the truck side of the facility and <br />approximately two cups of liquid were found in the diesel spill container on the auto side of the facility. Spill <br />containers shall be constructed to prevent any liquid retention. Note that fuel was found in the south diesel spill <br />container during the inspection on June 17, 2016. Continue to monitor for liquid in the spill containers and remove <br />the liquid when present. <br />This is a repeat violation, Class II. <br />Overall Inspection Comments: <br />Page 4 of 5 <br />
The URL can be used to link to this page
Your browser does not support the video tag.