My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
SR0084078_SSNL
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
L
>
LIBERTY
>
3271
>
2600 - Land Use Program
>
SR0084078_SSNL
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/16/2021 11:39:48 AM
Creation date
9/16/2021 11:28:18 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2600 - Land Use Program
FileName_PostFix
SSNL
RECORD_ID
SR0084078
PE
2602
STREET_NUMBER
3271
Direction
E
STREET_NAME
LIBERTY
STREET_TYPE
RD
City
ACAMPO
Zip
95220
APN
00510001
ENTERED_DATE
8/16/2021 12:00:00 AM
SITE_LOCATION
3271 E LIBERTY RD
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\tsok
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
65
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
4.0 GROUNDWATER ANALYSIS <br />4.1 Description of the depth to groundwater, seasonal fluctuations of groundwater depth, <br />directional flow and gradient: Description of depth to groundwater, seasonal fluctuations of <br />groundwater, directional flow and gradient are referred to in Section 4 of the Soil Suitability <br />Report prepared by Dillon & Murphy that is attached in the Appendix. <br />4.2 Description/discussion of any existing and/or potential groundwater <br />contamination issues in the general location of the site: Description of existing or potential <br />groundwater contamination issues in the general location of the site are referred to in Section 4.2 <br />of the Soil Suitability Report prepared by Dillon & Murphy (See Appendix). <br />4.3 Description of the current use of groundwater at the site and of the future expected use <br />of groundwater as related to the proposed development project: Based on the most recent <br />results from San Joaquin County's "Flood Control and Water Conservation District" report on <br />groundwater from Spring 2018, the estimated depth to groundwater was determined to be <br />65-75 feet below the surface. This was verified with the California Department of Water <br />Resource's Water Data Library. The results of the historic depth to ground water show that the <br />relative depth has not changed drastically throughout the years. It fluctuates minimally on a <br />yearly basis. The proposed improvements will not have a negative effect on the current depth to <br />ground water as the proposed usage is less than that of agriculture. See appendix for the site's <br />depth groundwater tables and diagrams. <br />5.0 SOURCES AND CALCULATED IMPACT OF NITRATE TO <br />GROUNDWATER <br />5.1 Description of all current off-site sources of nitrate to soil and groundwater in the general <br />up gradient area and the contribution of nitrate load from these sources to the project <br />site: Current off-site source of nitrate to soil and groundwater in the general up gradient area and <br />the contribution of nitrate loads are neighboring sites with septic systems with minimal to no <br />current impact to the site. <br />5.2 Description of impact of rainfall contribution of nitrate load to the project site: The <br />impact of rainfall contribution on the project site was obtained to determine the nitrate load. The <br />average monthly precipitation and evapotranspiration are required to calculate the site nitrate <br />load. These two values are used to estimate the deep percolation. The deep percolation is <br />estimated by analyzing the difference between the monthly average precipitation and the <br />evapotranspiration when the evapotranspiration exceeds the monthly average precipitation. The <br />available evapotranspiration was adjusted with an adjustment factor based landscaping on-site. <br />These calculations are attached in the Appendix. The calculations were done for the 2.95 acre <br />parcel. <br />The data for the potential evapotranspiration water was obtained from the California Irrigation <br />Management Information System (CIMIS). The project is located within an area designated as <br />Zone 12. Based on the values for this area along with the average monthly precipitation values <br />obtained from the Western Regional Climate Center (Station 262) for the Linden region an <br />estimate of the deep percolation of rain for the project was determined. <br />4 <br />
The URL can be used to link to this page
Your browser does not support the video tag.