WrEIRPLAN-3,
<br /> ARCHITECTURE
<br /> EXISTING ROOF DECK ENGINEERING
<br /> m- -- - ---- ------ ---- —. ._. . -----
<br /> INTERIOR DESIGN
<br /> 3 518", 20 GA. MTL. STUD
<br /> DIAG. BRACING AT 48"O.C..
<br /> FRP ON 314"TREATED PLYWOOD DECK TO TOP OF ROOF STRUCT.
<br /> OVER 3 518" 18 GA. MTL. STUD JOISTS ABOVE
<br /> AT 12"O.C. 604 COURTLAND STREET
<br /> 3 51$", 20 GA. MTL.STUD 3 518", 20 GA. MTL. STUD 3 518",20 GA. MTL. STUD
<br /> BRACING A.48"O.C. DIAG. BRACING AT 48"O.C.. DIAG, BRACING AT 48"O.C.. SUITE 1 DO
<br /> BACK TO WALT. _ - — TO TOP OF ROOF STRUCT. TO TOP OF ROOF STRUCT. ORLANDO, FLORIDA 32804
<br /> ABOVE ABOVE PH 407.646.5008
<br /> f � FX 407.629,9124
<br /> EXIST ROOF JOIST J FRP FINISH dN
<br /> 518"GYP. BD. CAP
<br /> FRONT&BOTTOMTHIS DOCUMENT IS SEAL:
<br /> CEILING SYSTEM AS
<br /> UNLESS THE ARCHITECT OREFOR N CONSTRUCTION"
<br /> r CEILING SYSTEM AS SCHED. r CEILING SYSTEM AS SCHED. — SIGNATURE AND SEAL APPEAR BELOW.S
<br /> CEILING SYSTEM AS SCHED. 4-#10 SCREWS
<br /> CEILING SYSTEM AS SCHED. � �j � SCHED.
<br /> EACH JOIST zcrr f
<br /> w CONNECTION
<br /> s WALL TYPE D WALL TYPE B
<br /> WALL TYPE J Y - v WALL TYPE A
<br /> TENANT LEASE 3 518", 20 GA., METAL STUDS 3 518",20 GA., METAL STUDS
<br /> 3 518",20 GA., METAL STUD U ADJACENT 518"GYP, BD. BOTH SIDES OF
<br /> w MTL. STUD LEDGER ` AT 16"O.C. WI INSULATION AT 16"O.C. WALL REF. TAI 02 FOR WALL
<br /> FURRING AT 16"O.C. [� LEASE
<br /> r UNDER JOISTS k z z BACKING z Ct, E ijj� cz
<br /> �_ 518"TYPE W GYP. BD. TO �L Q
<br /> DECK ABOVE 3 516",20 GA., METAL STUDS h- WALL TYPE E ' p WALL TYPE C a -� rn O�
<br /> WALL TYPE K " WALL TYPE Al V O
<br /> Lu AT 12"O.C. .= a• 3 518", 20 GA., METAL 6",20 GA., METAL STUDS AT :�N 6",20 GA., METAL STUDS AT 4
<br /> 6",20 GA., METAL STUD i U 9.�- 1 (� C7 518"GYP. BD.ONE SIDE OF a a
<br /> EXISTING FRAMING TO DECK ABV. ;: STUDS AT 16"O.C. 16"O.C.WI INSULATION a M 16"O.C.
<br /> FURRING AT 16"O.C. ., w U WALL ONLY. REF. 71A102 FOR U
<br /> FRP ON 518" DUROCK zi U
<br /> 0 FRP ON 518"GYP. BD. (WATER FRP ON 518"GYP. BD, (WATER WALL BACKING � p U ,
<br /> Q F RESISTANT IN KITCHEN AREAS) w RESISTANT IN KITCHEN AREAS) w LU
<br /> 518"GYP. BD.-TYPE'X' INSTALL 518" DUROCK AT j ABOVE DUROCK-REF.71A102 FOR of ABOVE DUROCK-REF. 71A102 FOR � y���7 SSP
<br /> DEMISING WALL IN WET AREAS U
<br /> EXISTING WALL Q w WALL BACKING WALL BACKING [r w
<br /> 518" DUROCK-FULL HT SEE 11A502 FOR w "`N l N LL ,w,- 3 518", 20 GA., METAL w
<br /> FINISH w 518"DUROCK TO 12"A.F.F. w 518"DU ROCK TO 12`A.F.F. w STUDS AT 16"O.C. w
<br /> 518"DUROGK TO 12"A.F.F. i @MOP SINK U) (KITCHEN&WET AREAS) of (KITCHEN &WET AREAS) ry
<br /> (KITCHEN&WET AREAS) ? BASE AS SCHED.
<br /> BASE A5 SCHED. BASE AS SOWED. ' ��.^
<br /> BASE AS SCHED. H
<br /> °" BASE AS SCHED. 7
<br /> BASE AS SCHED.
<br /> BASE AS SCHED. pFINISH FLOORING AS
<br /> FINISH FLOORING AS FINISH FLOORING AS FINISH FLOORING AS _ FINISH FLOORING ASFINISH FLOORING AS FINISH FLOORING ASSCHED.
<br /> SCHED. SCHED. " SCHED. SCHED.
<br /> ar:
<br /> SCHED. SCHED.
<br /> FA SECURE TO GOING. SLAB WI SECURE TO GONG. SLAB WI SET BOTTOM TRACK IN BED SET BOTTOM TRACK IN BED SECURE TO CONC. SLAB WI'
<br /> HILITHIT POWER ACTUATED OF SEALANT TO REDUCE OF SEALANT TO REDUCE H1LIT HIT POWER ACTUATED
<br /> -
<br /> SET BOTTOM TRACK IN BED OF HILIT-HIT POWER ACTUATED DEVICE AT 32"O.C. MAX.
<br /> SEALANT TO REDUCE WATER (EXISTING DEMISING WALL) DEVICE=AT 32"O.C. MAX. DEVICE AT 32"O.C. MAX. WATER TRANSFER WATER TRANSFER
<br /> TRANSFER AT WET LOCATIONS
<br /> 8
<br /> ) WALL7PE�J & K WALLTYPE H WALL TYPE G WALL TYPEF WALL TYPE D & E WALL TYPE B & C WALL TYPE A & ASCALE: 112" = 1'-0" DSCALE: 1-112" = 1 '-Q" b SCALE: 1 -112" = 1 '-0" DLE SCA : 1 -112" = 1 '-0" 4 SCALE: 1 -112" = 1 '-0" DSCALE: 1 -112" = 1 '-0" SCALE: 1 -112" = 1'.-0"
<br /> 9„
<br /> ■
<br /> CONSTRUCTION NOTES
<br /> 4 112" 4 112"
<br /> iiii4i
<br /> 11 " EXISTING DEMISING WALL TO REMAIN, PATCH AND REPAIR AS
<br /> REQUIRED.
<br /> EXISTING STOREFRONT GLAZING SYSTEM AND ENTRY DOOR TO
<br /> REMAIN. ALL GLAZING MUST BE TEMP. GLASS AND MEET ALL CODE
<br /> m
<br /> SAFETY REQUIREMENTS.
<br /> 4'-O"OC 4'-0"
<br /> MAXIMUM, MAXIMUM 1'6" 3116"
<br /> ' TYPICAL FROM ANY 3 PROVIDE TACTILE SIGN STATING "EXIT" IN COMPLIANCE WITH
<br /> MAXIMUM F 3"MIN FROM
<br /> ALONG CROSSING FROM i4TOTALjFASTENERS HILLFERES
<br /> LT318"DIAM.TEft
<br /> © PARTITION PARTITION 'ENDOF x2`Eh48EDINTCCCNCRETPORTER-2368. EDGE OF SLAB ICC/ANSI A117.1, AMERICAN NATIONAL STANDARD FOR ACCESSIBLE
<br /> AND USABLE BUILDINGS AND FACILITIES. INSTALL ADJACENT TO
<br /> PARTITION INPCSTrENSIONEDCONCORS TOBE4° (WHERE OCCURS) LATCH SIDE OF DOOR 60"ABOVE FINISHED FLOOR TO THE.CENTER
<br /> h9INfROMTENDCN8,ASVE 5'-9112" 4'-11112" 14'-6" 14'-6"
<br /> DRILLING FOR ANCHORS. LINE OF THE SIGN
<br /> SUPPORT•LOCATION DIAGRAM SUPPORT DETAIL PLAN VIEW 1
<br /> B H � INSTALL NEW ROOM SIGNAGE AT TOILET ROOM,.SEE DETAIL 51A102.
<br /> SELF-DRILLING, z
<br /> �___. SEE ENLARGED RESTROOM PLAN, 11A301.
<br /> NO 4W H J E
<br /> SELF-TAPPING BOTTOM OF
<br /> SAT ( I C9 ALUM. WALL CLOSURE TRIM BETWEEN COOLER&WALL.
<br /> TOP ANDBOTTOMOF TOP TRACKS 20 �01A 1> 10 COOLER REF. 21A401 TYP.
<br /> UPRIGHT PLATE EACH SIDE +I
<br /> GAUGE !_ e...._. 3 I
<br /> (6 TOTAL EACH SUPPORT x F _ -- '- 104
<br /> I � DASHED LINE ALONG WALL DESIGNATES WALL BACKER BOARD
<br /> 20 GAUGE MINIMUMT_._. � ��� " " "�" "�� "�" " LOCATIONS, FRT PLYWOOD OR 20 GA. MTL. BACKING IN WALL FOR
<br /> SUPPORT STUD x AT CORNERS,LAP TOP Imr
<br /> FASTEN TRACK TO DECK WO HI I PLATES AND FASTEN 2 I
<br /> TOGETHER i JUICING & ® E SUPPORT OF WALL RACKS EQUIP. SHELVING, ETC. - REF. DETAILS
<br /> XDNI.745"DIA X314°EMBED - I BLENDING UA 71A102 FOR BACKING REQUIREMENTS. COORDINATE WITH
<br /> PER ES REPORT ER-2358)AT24" SCREWS I o I EQUIPMENT PLAN A501.
<br /> MAX OC STAGGERED6
<br /> NO.8 SCREWS IN EACH I w.._-.r.. ___. . _. da ___,
<br /> SIDE OF EACH STUD; i E --. .mm --- ❑ G.C. TO INSTALL 518" PLYWD, PHONE BOARD- 1.8"WIDE X 18"TALL.
<br /> TOPANDBOTLOM I 9 $ MOUNT TOP OF BOARD 6"BELOW CEILING ABOVE MANAGER DESK.
<br /> MINIMUM z0 I I
<br /> cV
<br /> k CD i F € 13 -m; LOCATION OF RELOCATED ELECTRICAL PANEL.
<br /> wIii Iii
<br /> ----- -------------- -- ---____ _ 163P
<br /> 10 EXISTING 24"x24" MOP SINK.
<br /> 0 0 �
<br /> � O 5'-7" 6'-10 112" 6'-0" 7'-p" r BACK OF i No DATE REMARKS
<br /> HOUSE ,m. .ww. m 11 PROVIDE MOP/BROOM HOLDER, BOBRICK B-223x24; PROVIDE SOLID REVISIONS
<br /> w
<br /> IN WALL BLOCKING AS REQUIRED AND MOUNT PER
<br /> � ... . Vµµµ Wµ _ MANUFACTURER'S RECOMMENDATIONS.
<br /> I
<br /> D
<br /> 2'-0"STAINLESS PANELS 2 SIDE WALLS: PROVIDE MILDEW RESISTANT
<br /> C'' I 3'-7" 7 7 12 CAULK AT ALL EDGES.
<br /> PARTITION FRAMING DETAIL 3 10QA
<br /> SEATING 4'-5 112" 5'-�10 '-� - 13 REF. DETAIL 61A102 AND SHEET P201 FOR WATER HEATER DETAILS.
<br /> 100 16
<br /> WALL BRACING DETAIL 3 § E 1p.t4 I 14 FLOOR DRAIN -SLOPE FLOOR 114:12 MAX.
<br /> 16 .. ..,_ . _ _ _ __ _. �w. .d__.._._.
<br /> � � _
<br /> SCALE: NTS �1 a
<br /> I D €�' NOT USED.
<br /> ;�` f € 4 RETROOIVIT 7B I
<br /> 2 � '# a __. 102 r L __. _ .1D- 1
<br /> L I p L__ -_.___ _, 11- _ .., 16 EXISTING COLUMN TO REMAIN.
<br /> l / l ® 11 12
<br /> oH
<br /> H 1ne'r ktar
<br /> 5-3,,. 71-4118._3.. 13
<br /> 40'-6 314" INTERIOR DIMENSION .DUKE BAR
<br /> LEGEND
<br /> /'� 211 LINCOLN CENTER
<br /> ( - } DOOR SCHEDULE SHEET A102 STOCKTON, CALIFORNIA 95207
<br /> O WALL TYPE SEE DETAILS ABOVE
<br /> PROJECT NO: 2017,0594
<br /> XXXXXXXX DATE: 12,14.2017
<br /> ROOM DESIGNATION
<br /> NORTH
<br /> EXISTING STOREFRONT Al
<br /> FLOOR PLAN EXISTING WALL TO REMAIN
<br /> SCALE: 114" = 1'-p" FLOOR PLAN
<br /> NEW INTERIOR PARTITION, SEE WALL TYPES ABOVE
<br /> CHECKED, J S DRAWN: J W
<br />
|