Laserfiche WebLink
INTERPLAN. <br /> UNDERSIDE OF UNDERSIDE OF ARCHITECTURE <br /> STRUCTURE '�TURE ENGINEERING <br /> AETAL STUDS AT 16"OC ( ANGLE MOLDING INTERIOR DESIGN <br /> -QUIREDCROSS TEE OR ""`NOTE: MAIN TEE TO BE LOCATED EVERY 48" PROJECT MANAGEMENT <br /> DW5 <br /> SEE PLAN FOR HEIGHT CROSS CHANNEL O.C., CROSS MEMBER SPACING EVERY 16" O.C. <br /> 20 GA. METAL STUDS AT 16" OC DISCONTINUE CELING TILE AT MAI AND 12 GA HANGER WIRE LOCATED EVERY 48 <br /> BRACE AS REQUIRED 12'-0"A.F.F. NEAREST'T' GRID OVERL TEE <br /> ACOUSTICAL CEILING TILE AND'T' <br /> SEATING CEILING COOLER/FREEZER BAR GRID - _ <br /> SHTROCK BRAND O JOjNf 12 GA. HANGER <br /> 604 COURTLAN©STREET <br /> 1"ALUM, ANGLE ATTACHED TO. GYPSUM PANEL WIRE SUITE 100 <br /> GENERAL NOTE: S EETROCK BRAND <br /> VARIES CELING GRID BEYOND m <br /> ORLANDO, FLORIDA 32804 <br /> CEILING AREA WITH CONTROL JOINT <br /> B.O. CLG. GYPSUM PANEL PH 407.645.5008 <br /> MUST FOLLOW LATERAL BRACING FX 407.629.9124 <br /> SHEETROCK BR` REQUIREMENTS (IF APPLICABLE) . <br /> CEILING AS SCHEDULED -518"20 GA. METAL STUDS AT 16" OC GYPSUM PANEL <br /> SCREW INTO SEAL: <br /> 3RACE AS REQUIRED LARR#25764 <br /> MOLDING MAIN TE .. ° THIS 170CUMENT f5"NOT FOft CONSTRUCTION" <br /> TOP OF COOLER BOX SIS CLOSURE PANEL WI HEMMED ® SIGNATUNLESSURE <br /> THEARCHEALATECT OR APPEAR <br /> W. <br /> PAINTED GYP. BD. TO EXTEND 6 PAST AT PERIMETE sIGNATUREANIJSEALAPPEARBELOW. <br /> ACT. CLG. SEE SHEET A401 FOR FINISH EDGE AT BOTTOM. FASTENED TO ` <br /> ANGLE AND FREEZER. EXTEND 4 ��� <br /> INFORMATION 112" DOWN SIDE OF FREEZER <br /> .............. . <br /> CROSS CHANNEL <br /> FIRE EXPANSION <br /> SEE PLAN 9'-D"A.F.F. <br /> B.C. HEADER HALLWAY CEILING PREFABRICATED WALK-IN COOLER NOTCH <br /> MAIN TEE SPLICE `ct' lye, a <br /> CORNER BEAD-ALL `�— <br /> CORNER BEAD -ALL O <br /> EXPOSED CORNERS EXPOSED CORNERS <br /> r m co Q r <br /> ¢ - Co co L <br /> 0 co <br /> CTLON HEADER SECTON CLG HT CHANGE 4 S/S CLOSURE AT COOLER 5GYP BD CEILING DETALLS 'QIE <br /> SCALE.; 1__ <br /> &SCALE ' <br /> : l -1/2" = l'-0" SCALE: SCALE: 1 -1/2" = 1 '-�" <br /> REFLECTED CEILING LEGEND <br /> NOTES: <br /> 1. HEAVY DUTY T-BAR GRID. <br /> 2. SPRINKLER DROPS AND OTHER PENETRATIONS THROUGH THE CEILING DECORATIVE LIGHT BY OW - <br /> BASKET LIGHT <br /> SHALL HAVE A 2" OVERSIZED RING, SLEEVE, OR ADAPTER THROUGH THE <br /> CEILING TO ALLOW FOR FREE MOVEMENT OF AT LEAST 1" IN ALL HORIZONTAL <br /> DIRECTIONS. ALTERNATIVELY, A SWING JOINT THAT CAN ACCOMMODATE 1" OF <br /> CEILING MOVEMENT IN ALL HORIZONTAL DIRECTIONS IS PERMITTED TO BE <br /> PROVIDED AT THE TOP OF THE SPRINKLER HEAD EXTENSIONS. 0 A RECESSED DOIX SERI <br /> MERILUX, CLASSIX SERIES <br /> - VERTICAL COMPRESSION <br /> STRUT @ 12" O.C. 6" RECESSED WALL WASHER <br /> — 2" MAX. FROM no <br /> AMERILUX, CLASSIX SERIES ARROW <br /> 12 GA. VERTICAL BRACING WIRES TO <br /> INDICATES DIRECTION: <br /> HANGER WIRE @ CROSS TEES. <br /> 48" 12 GA. BRACING WIRE @ <br /> O.C. EA. WAY TO 48" O.C. EA. WAY TO BE <br /> 14T%711BE �y.P�' 2° ATTACHED @ MAX. OF �I RESTROOM EXHAUST FAN <br /> (48"O.C. AT MAIN 45 DEGREES, MIN. OF 4 <br /> RUNNER) -MIN. TIGHT TURNS IN 1 112" @ <br /> OF 3 BATH SIDES OF ALL6 <br /> I <br /> 3 <br /> RETURN AIR GRILL-SEE MECHANICAL DRAWINGS <br /> TIGHT TURNS IN BRACING WIRE, TYP. <br /> 3 - _ <br /> BOTH SIDES TYP. ` <br /> ' MAIN RUNNER @ 4'-0" O.C. <br /> SHIM AS NEEDEDI <br /> I „�� � SUPPLY AIR GRILL-SEE MECHANICAL DRAWINGS <br /> CROSS TEE @ 2'-0" <br /> O.C. OR V-0" O.C. AS <br /> SHOWN <br /> NOTES: <br /> 1. ALL 24"X48" CEILING LIGHT FIXTURES &24"X24" HVAC AIR REGISTERS SHALL n <br /> BE SUPPORTED BY A MINIMUM OF (2) HANGERS @ OPPOSITE CORNERS. <br /> CEILING SYSTEM SHALL NOT SUPPORT OTHER ITEMS. <br /> 8'-6", <br /> 2. ALL INTERIOR WALL& CEILING FINISHES SHALL BE INSTALLED TO CLASS III <br /> Q <br /> FLAME SPREAD. P- 1 <br /> 3. 45 DEGREE BRACE WIRES &COMPRESSION STUDS ARE TO BE PROVIDED P 1 <br /> ONLY IF REQUIRED BY LOCAL BUILDING DEPARTMENT. <br /> 4. COMPRESSION STRUTS: STEEL SECTION WITH LIR RATION OF 200 MAXIMUM. <br /> r <br /> ATTACH TO MAIN RUNNERS WITH 114" MACHINE BOLT AND TO STRUCTURE WITH <br /> 3116" DAIMETER POWER DRIVEN STUD. COMPRESSION STRUT SHALL NOT o <br /> REPLACE HANGER WIRE. <br /> 8"MAX no <br /> ` £ U <br /> 4'-1 1.12" 4'-1 112" I COOLER ! <br /> _ o <br /> HANGER WERE. 1D4 O <br /> HANGER WIRE. <br /> 314" <br /> ANGLE SUPPORT ANGLE SUPPORT © 8'-2 112" 8'-2 112" $ <br /> SEE.ESR#1308 SEE ESR#130$ <br /> FOR BERC CLIPcs <br /> FOR BERG CLIP <br /> JU NG, <br /> MAINTAIN 314" ATTACH CEILING - -? p ..,. <br /> BLE D <br /> CLEARANCE FROM MIN' PANEL TO ANGLE M N' � .. ..m_ _._ NO DATE REMARKS <br /> 1 „I�� <br /> M <br /> WALL B 1 �' _ y <br /> REVISIONS <br /> A. FREE SIDE SUPPORT B. ATTACHED SIDE 1'-4„ v 4'-1 112" 4'-1 112" 4'-1 112" 4'-1 112 <br /> " m., `e0 <br /> NOTE: '"" o <br /> LATERAL FORCE BRACING MEMBERS SHALL BE SPACED A MINIMUM OF 6" FROM ALL ,E + BACK OF I -f /� <br /> HORIZONTAL PIPING OR DUCT WORK THAT IS NOT PROVIDED WITH BRACINGd� " ? HOUSE € I; pE�{ <br /> REFLECTED �+EIL�NG PLAN NOTES <br /> o <br /> RESTRAINTS FOR HORIZONTAL FORCES. BRACING WIRES SHALL BE ATTACHED TO f` L V 1 L.� <br /> THE GRID AND TO THE STRUCTURE IN SUCH A MANNER THAT THEY CAN SUPPORTA C° 103 I <br /> DESIGN LOAD OF NOT LESS THAN 200 POUNDS OR THE ACTUAL LOAD. WHICHEVER IS <br /> 3' <br /> GREATER, WITH A SAFETY FACTOR OF 2. MANUFACTURER: USG INTERIORS, 31/2" -11 112" 4'-1 112" 4'-1 112" 4'-1 112" 5'-8 1I2" 3'-3 112" 6'-0" 5'-2 114" FINISH CEILING HEIGHT SHALL BE AS NOTED <br /> It <br /> 4 <br /> INC. �_....M - <br /> mI UNLESS OTHERWISE NOTED OR CODED, ALL FIXTURES SHOWN ARE NEW LD <br /> 1 � f,�. CV `.. <br /> NOTE: SUSPENDED ACOUSTICAL CEILING SYSTEM SHALL 8E INSTALLED IN "� 9 w" I <br /> s <br /> ACCORDANCE WITH THE PROVISIONS OF ASTM C 635 AND ASTM C 636, SEC 1613.1 _._._._".".w.__.u..- -�,_�._______.-_._ �_ o ,� THE CONTRACTOR SHALL CAREFULLY REVIEW ALL ATTACHMENT <br /> ._ _ " _ .._._. . CONDITIONS FOR NEW FURRED OR SUSPENDED CEILING TO ASSURE o <br /> 7 SEATING <br /> 3 <br /> PROPER CLEARANCES. <br /> I' ;3 <br /> looLL <br /> R SHA <br /> &LEISMIC BRACING DETAILS LS TO THE <br /> ±3-1{' ' - mm� 10'MO' W- �3 -p AC <br /> ---w " E.Q. 11, <br /> 4'-D" E.Q. EXISTING BUILDITHE NG STRUCTURE WITH EW TTHEILAND ORDENT IPRIOR TO <br /> O <br /> $GALE: 1I4" = 1 '-O" I $ _ CONSTRUCTION. <br /> 1 � �,�_; ._ __a.-" L.".. ��.._ . ._".., ,= 2'-1 112.. d W <br /> �a.a E.Q. w 3'-9" UE:�Q. <br /> 3 �,., yll <br /> Ii ne <br /> SEE ELECTRICAL PLAN FOR FIXTURES CIRCUITED TO EMERGENCYktar <br /> _ „ II I POWER <br /> K ¢" I <br /> ="=`� SEE HVAC PLAN TO COORDINATE CEILING DIFFUSERS, GRILLES,AND JUIICE BAR <br /> r ; FAN LOCATIONS SHOWN ON THIS DRAWING FOR LOCATION ONLY) <br /> __.. .,,...m .__.._ ..m._w.__ �_.e_.___�. r I ��� -�I , <br /> EQ 4'-3" 4'-3" 4'-3" EQ -1 uj I t <br /> _.._ .____"__e_._.. M, .__m._•_. ___... .,.,....._._.._._ _e"_____..,.M.... ,_..__..__ .___.., +i III SPEAKER SYSTEM BY OWNER <br /> 211LINCOLN CENTER. w <br /> G.C. TO CONFIRM FOOTCANDLES IN FOOD PREP AREA ARE.IN STOCKTON, CALIFORNIA 95201 <br /> CONFORMANCE WITH LOCAL JURISDICTION HEALTH CODES. <br /> c� <br /> RESTROOM } <br /> 102CONFIRM LOCATIONS OF SEATING AREA LIGHTING WITH OWNER o <br /> PRIOR TO INSTALLATION. <br /> PROJECT NO: 2017.0599 r <br /> P-1 <br /> P-1 LIGHTING TO BE PROPERLY LENSED FOR FOOD PREP. DATE: 12,14.2017 <br /> c� <br /> J <br /> J <br /> z <br /> g <br /> c <br /> NORTH Z <br /> CEILING HEIGHT ABOVE FINISHED FLOOR A201 <br /> #'-#" o <br /> j N <br /> REF LECTE D CE ICING PLAN ___-- -CEILING FINISH-SEE SCHEDULE REFLECTED CEILING PLAN O <br /> SCALE: 114" <br /> r <br /> CHECKED J S DRAWN' J W 0 <br />