My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
WORK PLANS
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
W
>
WATERLOO
>
4426
>
1600 - Food Program
>
PR0529513
>
WORK PLANS
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/1/2021 2:35:21 PM
Creation date
10/1/2021 2:32:36 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
1600 - Food Program
File Section
WORK PLANS
RECORD_ID
PR0529513
PE
3116
FACILITY_ID
FA0016051
FACILITY_NAME
STARBUCKS COFFEE #7957
STREET_NUMBER
4426
Direction
E
STREET_NAME
WATERLOO
City
STOCKTON
Zip
95215
APN
10102158
CURRENT_STATUS
02
SITE_LOCATION
4426 E WATERLOO
P_LOCATION
99
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\jcastaneda
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
26
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
1. THE DRAWINGS AND PROJECT MANUAL TOGETHER CONSTITUTE THE CONTRACT DOCUMENTS FOR CONSTRUCTION. ALL GENERAL REQUIREMENTS ARE TO BE MET AND ALL MATERIALS, FINISHES AND SYSTEMS ARE TO BE INSTALLED AND PERFORM PER SPECIFICATIONS UNLESS OTHERWISE NOTED.2. GENERAL CONTRACTOR SHALL VISIT THE SITE, REVIEW THE BUILDING SHELL DRAWINGS AS SUBMITTED BY THE LANDLORD OR STARBUCKS AND BECOME THOROUGHLY FAMILIAR WITH THE SITE CONDITIONS PRIOR TO CONSTRUCTION. 3. GENERAL CONTRACTOR SHALL CONSULT WITH STARBUCKS CONSTRUCTION MANAGER TO RESOLVE ANY CHANGES, OMISSIONS OR PLAN DISCREPANCIES PRIOR TO CONSTRUCTION.4. ALL WORK SHALL BE PERFORMED IN STRICT COMPLIANCE WITH LOCAL, COUNTY, STATE AND FEDERAL CODES AND ORDINANCES.5. GENERAL CONTRACTOR SHALL VERIFY THE LOCATION OF ALL UTILITIES.6. GENERAL CONTRACTOR TO VERIFY ALL DIMENSIONS, INCLUDING CLEARANCES REQUIRED BY OTHER TRADES AND NOTIFY STARBUCKS CONSTRUCTION MANAGER OF ANY DISCREPANCIES PRIOR TO PROCEEDING WITH THE WORK. ALL DIMENSIONS ARE TO THE FACE OF THE FINISHED SURFACE UNLESS NOTED OTHERWISE. ALL DIMENSIONS TO BE TAKEN FROM DESIGNATED DATUM POINT. DO NOT SCALE DRAWINGS.7. GENERAL CONTRACTOR SHALL PATCH AND REPAIR ALL EXISTING WALLS, FLOORS, CEILINGS, OR OTHER SURFACES IDENTIFIED TO REMAIN THAT MAY BECOME DAMAGED DURING THE COURSE OF THE WORK.8. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR OBTAINING PERMITS FOR FIRE PROTECTION, PLUMBING, MECHANICAL, AND ELECTRICAL SYSTEMS PRIOR TO INSTALLATION OF SUCH SYSTEMS.9. GENERAL CONTRACTOR SHALL RETAIN ONE SET OF PERMIT PLANS ON-SITE TO DOCUMENT ALL CHANGES MADE DURING CONSTRUCTION. THE RECORD DRAWINGS SHALL BE ISSUED TO THE OWNER AT PROJECT CLOSE-OUT AS DESCRIBED IN THE GENERAL REQUIREMENTS OF THE PROJECT MANUAL.10. GENERAL CONTRACTOR IS RESPONSIBLE FOR COORDINATING DELIVERY OF MATERIALS FROM STARBUCKS CONTRACTED THIRDPARTY LOGISTICS DISTRIBUTION SERVICES AND VENDOR DIRECT SHIPMENTS. SEE THE PROJECT MANUAL FOR ADDITIONAL INFORMATION.11. RESPONSIBILITY FOR SUPPLY AND DELIVERY OF MATERIALS AND EQUIPMENT IS IDENTIFIED IN THE DRAWING SCHEDULE SHEETS UNDER THE COLUMN LABELED "RESPONSIBILITY".12. FOR THE PURPOSE OF THE DOCUMENTS, TO “INSTALL”, SHALL MEAN TO PROVIDE ALL FASTENERS, MISCELLANEOUS HARDWARE, BLOCKING, ELECTRICAL CONNECTIONS, PLUMBING CONNECTIONS AND OTHER ITEMS REQUIRED FOR A COMPLETE AND OPERATIONAL INSTALLATION, UNLESS OTHERWISE NOTED.13. ALL ITEM SUBSTITUTIONS MUST BE APPROVED BY THE STARBUCKS CONSTRUCTION MANAGER.MAILING ADDRESS:DESIGN MANAGER:JESSICA RAMOSSTARBUCKS COFFEE COMPANY60 SPEAR STREET 7TH FLOORSAN FRANCISCO, CA 94105(415) 361.3540 PHONEJRAMOS@STARBUCKS.COMSTARBUCKS COFFEE COMPANY2401 UTAH AVENUE SOUTHMS STOP: S-SD10SEATTLE, WASHINGTON 98134(206) 318-1575CONSTRUCTIONMANAGER:JASON VOYERSTARBUCKS COFFEE COMPANY60 SPEAR STREET 7TH FLOORSAN FRANCISCO, CA 94105(415) 254.3249 PHONEJVOYER@STARBUCKS.COMLANDLORD:EUGENE, LOUIS AND MARION MANGINI24 MANGINI DRIVEPLEASANT HILL, CA 94523925-934-7267ARCHITECT OF RECORD:JOSE LAROCCAVALERIO ARCHITECTS5858 WILSHIRE BLVD. SUITE 200LOS ANGELES, CA 90036(323) 954-8996 X2 PHONE(323) 954-8965 FAXJLAROCCA@VALERIOINC.COMMEPCONSULTANT OF RECORD:MILAN PESAKOVIC3371 OLCOTT STREETSANTA CLARA, CA 95054(408) 522-5255 EXT 123 PHONE(408) 522-5260 FAXMILAN@ACIES.NETINTERIOR RENOVATION OF AN EXISTING STARBUCKS CAFE. SCOPE OF WORK IS COMPRISED OF NEW EQUIPMENT AND CABINETRY AT ENGINE ONLY. NO EXTERIOR WORK.CODE AUTHORITIES:BUILDING CODE: 2019 CALIFORNIA BUILDING CODEPLUMBING CODE: 2019 CALIFORNIA PLUMBING CODEMECHANICAL CODE: 2019 CALIFORNIA MECHANICAL CODEELECTRICAL CODE: 2019 CALIFORNIA ELECTRICAL CODEENERGY CODE: 2019 CALIFORNIA ENERGY CODEFIRE CODE: 2019 CALIFORNIA FIRE CODEGREEN BUILDING CODE: 2019 CALIFORNIA GREEN BUILD CODEZONING:LEGAL DESCRIPTION: APN 101-021-580-000ZONING: IL - LIMITED INDUSTRIALA/C AIR CONDITIONINGACT ACOUSTICAL CEILING TILEADJ ADJUSTABLEAFF ABOVE FINISHED FLOORAMP AMPEREARCH ARCHITECTBOH BACK OF HOUSECAB CABINETCL CENTER LINECLG CEILINGCM STARBUCKS CONSTRUCTION MANAGERCTR CENTERCX COMMISSIONINGCXA COMMISSIONING AGENTDEG DEGREEDET DETAILDIA DIAMETERDIM DIMENSIONDM STARBUCKS DESIGN MANAGERDN DOWNEA EACHEL ELEVATIONEQ EQUALEXIST EXISTINGEXT EXTERIORFF&E FURNITURE, FIXTURE, AND EQUIPMENTFLR FLOORFOH FRONT OF HOUSEFOIC FURNISHED BY OWNER, INSTALLED BY CONTRACTORFOIO FURNISHED BY OWNERINSTALLED BY OWNERFT FOOT/FEETG GROUNDGC GENERAL CONTRACTORGWB GYPSUM WALLBOARDHC HOLLOW COREHDW HARDWAREHM HOLLOW METALHORIZ HORIZONTALHR HOURHT HEIGHTHVAC HEATING, VENTILATINGAND AIR CONDITIONINGI.D. INSIDE DIAMETERLEED LEADERSHIP IN ENERGYAND ENVIRONMENTAL DESIGNLL LANDLORDLV LOW VOLTAGEMAX MAXIMUMMEP "MECHANICAL, ELECTRICALAND PLUMBING"MFR MANUFACTURERMIN MINIMUMNIC NOT IN CONTRACTNL NIGHT LIGHTNTS NOT TO SCALEOC ON CENTERO.D. OUTSIDE DIAMETERPIR PASSIVE INFRARED SENSORPLC PLACER RADIUSREF REFERENCEREQ‘D REQUIREDREV REVISIONRND ROUNDSB STARBUCKSSC SOLID CORESF SQUARE FEETSHT SHEETSIM SIMILARSPEC SPECIFICATIONSQ SQUARETEMP TEMPORARYTYP TYPICALUC UNDER COUNTERUNO UNLESS NOTED OTHERWISEVERT VERTICALVIF VERIFY IN FIELDX' XX"XNORTH ARROWXXXX AFFXXScale: X =X0 2 4 8GRAPHIC SCALEDATUM POINTEXTERIORELEVATIONCALL-OUTINTERIORELEVATION CALL-OUTSECTION CALL-OUTDETAIL CALL-OUTREVISION TAGPAINTTAGDESIGN IDTAGSHEET NOTE CALLOUTABOVE FINISH FLOOR HEIGHT TAGFINISH FACE TO FINISH FACE DIMENSIONREVISION CLOUDPTXXXXXXXXXXXXXXXXWDOORTAGWINDOWTAGXXXXXDXXINTERIOR WALL TAGGCLLSBVDGENERAL CONTRACTORLANDLORDSTARBUCKSVENDORUSE: COFFEE SHOP WITH DRIVE THRU(NO CHANGE OF USE)OCCUPANCY TYPE: BCONSTRUCTION TYPE: V-B# OF STORIES: 1BUILDING HEIGHT: 20'-8"FIRE SPRINKLER: NON-SPRINKLEREDGROSS TENANT AREA: 1,583 SQFTNET TENANT AREA: 1,425 SQFTNUMBER OF EMPLOYEES/SHIFT: 4NUMBER OF EXITS: 1 PROVIDED / 1 REQUIREDSEE SHEETS G002 FOR PLUMBING FIXTURES CALCULATIONSSITE WORK: SITE ADA UPGRADES, IF ANY REQUIRED, ARE TO BE BY LANDLORD UNDER SEPARATE PERMITSHEET NUMBER:SHEET TITLE:SCALE:STORE #:PROJECT #:PROJECT NAME:PROJECT ADDRESS:C 2020 STARBUCKS COFFEE COMPANYRISSUE DATE:2401 UTAH AVENUE SOUTHSEATTLE, WASHINGTON 98134(206) 318-1575THESE DRAWINGS AND THE PROJECT MANUAL ARE CONFIDENTIAL AND SHALL REMAIN THE SOLE PROPERTY OF STARBUCKS CORPORATION, WHICH IS THE OWNER OF THE COPYRIGHT IN THIS WORK. THEY SHALL NOT BE REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF STARBUCKS CORPORATION. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO EXPRESS DESIGN INTENT FOR A PROTOTYPICAL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO NOT REFLECT ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL HAVE ANY OBLIGATION NOR LIABILITY TO THE OTHER (EXCEPT STATED ABOVE) UNTIL A WRITTEN AGREEMENT IS FULLY EXECUTED BY BOTH PARTIES.STARBUCKS TEMPLATE VERSION: i2020-07-27STARBUCKSRSR. DESIGN MANAGER:DESIGN MANAGER:CHECKED BY:G00123871-06802-05-21HIGHWAY 99 & WATERLOO4426 EAST WATERLOO ROADSTOCKTON, CA 95215COUNTY OF SAN JOAQUIN7957JESSICA RAMOSJESSICA RAMOSVALERIOGENERALINFORMATIONSHEET SHEET TITLE REVISION 1 REVISION 2 REVISION 3 REVISION 4 GENERALG001 GENERAL INFORMATIONG002 LIFE SAFETY AND ACC. PLANG003 EXISTING PHOTOSDEMOLITIOND101 DEMOLITION FLOOR PLANARCHITECTURALA001 ARCHITECTURAL SITE PLANINTERIORSI101 FF&E & PENET. PLANI102 CSWK & FLOOR FINISH PLANI501 CASEWORK ELEVATIONSI503 INTERIOR DETAILSI530 INTERIOR DETAILSI601 CASEWORK AND FF&E SCHEDULESI701 GENERAL NOTESI702 GENERAL NOTESI703 GENERAL NOTESELECTRICALE001 ELECTRICAL NOTESE002 ELECTRICAL OUTLINE SPECIFICATIONSE103 ELECTRICAL POWER DESIGNE601 LUTRON CONTROL DIAGRAMPLUMBINGP001 PLUMBING SYMBOLS LIST & ABBREVIATIONSP002 PLUMBING OUTLINE SPECIFICATIONSP003 PLUMBING OUTLINE SPECIFICATIONSP004 SCHEDULES AND CALCULATIONSP101 PLUMBING SUPPLY PLANP103 PLUMBING WASTE & VENT PLANP501 PLUMBING DETAILSINDEX OF SHEETSGENERAL NOTESPROJECT CONTACTSARCHITECTURAL SYMBOL LEGENDABBREVIATIONSRESPONSIBILITY LEGENDVICINITY PLANAERIAL MAPDEFERRED / SEPARATE PERMITSSCOPE OF WORKSITE INFORMATIONBUILDING INFORMATIONRevision ScheduleRev Date By Description01-28-21 JGR FINAL REVIEW SET02-05-21 JGR PERMIT SET123N/ASan Joaquin County Environmental Health Department 1868 E. Hazelton Ave. Stockton, CA 95205 (209) 468-3420 APPROVED WITH CONDITIONS For conditions, please see approval letter dated: Approved by:_______________________Date:_______________ 2-18-21Feb 18, 2021 Victor Acevedo
The URL can be used to link to this page
Your browser does not support the video tag.