Laserfiche WebLink
122234455776689101133A. GENERAL CONTRACTOR TO SCHEDULE WITH REFRIGERATION CONTRACTOR TO CONDUCT INITIAL FOOD CASE START-UP AND TESTING. FOR APPROVED CONTRACTOR, CONTACT THE VENDOR.B. THE SPACE IS SERVED BY THE MUNICIPAL WATER AND SEWER SYSTEM UNLESS OTHERWISE NOTED.C. ALL EQUIPMENT AND INSTALLATION WILL MEET NATIONAL SANITATION FOUNDATION STANDARDS OR EQUIVALENT.D. EQUIPMENT UNITS SHALL CONTAIN NO EXPOSED THREADS, EMBELLISHMENTS OR OVERHANGING EDGES THAT SERVE AS PLACES FOR ACCUMULATION OF DUST, DIRT AND DEBRISE. WARMING OVEN(S) SHOWN FOR PERMITTING PURPOSES. INSTALLATION AT STORE OPENING TO BE VERIFIED BY STARBUCKS CONSTRUCTION REPRESENTATIVE.F. EACH HAND WASHING WILL HAVE A SINGLE SERVICE TOWEL AND SOAP DISPENSER AND ALL HAND SINKS TO HAVE A COMBINATION FAUCET OR PREMIXING FAUCET.G. PROVIDE SNEEZE GUARDS WHERE REQUIRED BY JURISDICTION.H. ALL FOOD STORAGE AND DISPLAY SHELVING SHALL BE A MINIMUM 6" (150MM) ABOVE FINISH FLOOR.1. THRESHOLDS TO BE BARRIER FREE COMPLIANT PER ALL APPLICABLE CODES.2. BARRIER-FREE PATH OF TRAVEL (MIN 3'-8").3. 30" (160 MM) X 48" (1220 MM) CLEAR FOR WHEELCHAIR ACCESS.4. 60" (1525 MM) DIAMETER MINIMUM TURN RADIUS FOR WHEELCHAIR ACCESS.5. 32" (815 MM) MINIMUM CLEAR AT RESTROOM DOOR.6. POS TRANSACTION PLANE, CONDIMENT CART TOP AND HAND-OFF PLANE ARE 34 INCHES (860 MM) ABOVE THE FINISHED FLOOR FOR WHEELCHAIR ACCESSIBILITY.7. PROVIDE BARRIER-FREE SIGNAGE AT ACCESSIBLE RESTROOMS PER ALL APPLICABLE CODES.8. PROVIDE TACTILE "EXIT" SIGNAGE.9. PROVIDE INTERNATIONAL SYMBOL OF ACCESSIBILITY SIGN WHERE REQUIRED BY APPLICABLE LAWS OR CODES.10. DOORS IN THE MEANS OF EGRESS SYSTEM TO BE OPENABLE FROM THE INSIDE W/O ANY USE OF A KEY OR ANY SPECIAL KNOWLEDGE OR EFFORT.11. FIRE EXTINGUISHERPLUMBING FIXTURES: OCCUPANCY LOAD CALCULATIONINT. SEATING: 552 S.F. / 30 = 18.4EXT. SEATING: 202 S.F. / 30 = 6.7REMAINING: 671 S.F. / 200 = 3.3TOTAL: = 28(14 MEN, 14 WOMEN)REQUIRED PROVIDEDWATER CLOSETS:MALE 1:1-50 1 1FEMALE 1:1-25 1 1LAVATORIES:MALE 1:1-150 1 1FEMALE 1:1-150 1 1TOTAL SEATING:PROPOSED INT. SEATING: 27 SEATS/ 11 TABLESINT. ADA SEATING: REQUIRED (27 x 5%) = 1,35, PROVIDED = 2 PROPOSED EXT. SEATING: 14 SEATS/ 6 TABLESEXT. ADA SEATING: REQUIRED (14 x 5%) = 0.7, PROVIDED = 1 A. EVERY ROOM OR SPACE THAT IS ASSEMBLY OCCUPANCY SHALL HAVE THE OCCUPANT LOAD OF THE ROOM OR SPACE POSTED IN A CONSPICUOUS PLACE, NEAR THE MAIN EXIT ACCESS DOORWAY. POSTED SIGNS SHALL BE OF AN APPROVED LEGIBLE PERMANENT DESIGN AND SHALL BE MAINTAINED BY THE OWNER AUTHORIZED AGENT. (CBC 1004.9)B. EGRESS SHALL NOT PASS THROUGH KITCHENS, STORAGE ROOMS, CLOSETS OR SIMILAR SPACES. (CBC 1016.2.5)C. WHERE PANIC OR FIRE EXIT HARDWARE IS INSTALLED, IT SHALL COMPLY WITH THE FOLLOWING (CBC 1010.1.10.1):1) PANIC HARDWARE SHALL BE LISTED IN ACCORDANCE WITH UL 305.2) FIRE EXIT HARDWARE SHALL BE LISTED IN ACCORDANCE WITH UL 10C AND UL 305.3) THE ACTUATING PORTION OF THE RELEASING DEVICE SHALL EXTEND NOT LESS THAN ONE-HALF OF THE DOOR LEAF WIDTH.4) THE MAXIMUM UNLATCHING FORCE SHALL NOT EXCEED 15 POUNDS (67 N).D. IF BALANCED DOORS ARE USED AND PANIC HARDWARE IS REQUIRED, THE PANIC HARDWARE SHALL BE THE PUSH-PAD TYPE AND THE PAD SHALL NOT EXTEND MORE THAN ONE-HALF THE WIDTH OF THE DOOR MEASURED FROM THE LATCH SIDE. (CBC 1010.1.10.2)E. STRUCTURAL ELEMENTS, FIXTURES OR FURNISHINGS SHALL NOT PROJECT HORIZONTALLY FROM EITHER SIDE MORE THAN 4 INCHES (100 MM) OVER ANY WALKING SURFACE BETWEEN 27 INCHES (685 MM) AND 80 INCHES (2030 MM) ABOVE THE WALKING SURFACE.EXCEPTION: HANDRAILS SERVING STAIRS AND RAMPS ARE PERMITTED TO PROTRUDE 4 1/2 INCHES (115 MM) FROM THE WALL. (CBC 1003.3.3)F. THE PATH OF EGRESS TRAVEL EXITS AND WITHIN EXITS IN THIS BUILDING SHALL BE IDENTIFIED BY EXIT SIGNS CONFORMING TO THE REQUIREMENTS OF CBC SECTION 1013 AND AS NOTED BELOW:1) EXIT SIGNS SHALL BE READILY VISIBLE FROM ANY DIRECTION OF EGRESS TRAVEL.2) EXIT SIGNS SHALL BE LOCATED AS NECESSARY TO CLEARLY INDICATE THE DIRECTION OF EGRESS TRAVEL.3) NO POINT IN A CORRIDOR SHALL BE MORE THAN 100 FT (30.5 M) OR THE LISTED VIEWING DISTANCE FOR THE SIGN, WHICHEVER IS LESS, FROM THE NEAREST VISIBLE EXIT SIGN.G. WHERE KEY OPERATED LOCKING DEVICES ARE USED, POST A SIGN ON OR ADJACENT TO THE REQUIRED MAIN EXIT DOOR WITH 1 INCH (25 MM) LETTERING STATING THAT "THIS DOOR TO REMAIN UNLOCKED WHEN BUILDING IS OCCUPIED". (1010.1.9.4)H. EGRESS DOORS OR GATES SHALL BE OPENABLE FROM THE EGRESS SIDE WITHOUT THE USE OF A KEY, SPECIAL KNOWLEDGE OR EFFORT. DOOR HANDLES, PULLS, LATCHES, LOCKS AND OTHER OPERATING DEVICES ON DOORS REQUIRED TO BE ACCESSIBLE BY CHAPTER 11A OR 11B SHALL NOT REQUIRE TIGHT GRASPING, TIGHT PINCHING OR TWISTING OF THE WRIST TO OPERATE. MANUALLY OPERATED FLUSH BOLTS OR SURFACE BOLTS ARE NOT PERMITTED. THE UNLATCHING OF ANY DOOR OR LEAF SHALL NOT REQUIRE MORE THAN ONE OPERATION. (CBC 1010.1.9)I. THERE SHALL BE A FLOOR OR LANDING ON EACH SIDE OF A DOOR. SUCH FLOOR OR LANDING SHALL BE AT THE SAME ELEVATION ON EACH SIDE OF THE DOOR. LANDINGS SHALL HAVE A WIDTH NOT LESS THAN THE WIDTH OF THE STAIRWAY OR THE DOOR, WHICHEVER IS GREATER. LANDINGS SHALL HAVE A LENGTH MEASURED IN THE DIRECTION OF TRAVEL OF NOT LESS THAN 44 INCHES (1118 MM) (CBC 1010.1.5 & 1010.1.6)ADA ACCESSIBLE SEATING36" (915MM) X 48" (1220MM) CLEAR AREABACK OF HOUSEPREPSEATINGQUEUERETAILSHEET NUMBER:SHEET TITLE:SCALE:STORE #:PROJECT #:PROJECT NAME:PROJECT ADDRESS:C 2020 STARBUCKS COFFEE COMPANYRISSUE DATE:2401 UTAH AVENUE SOUTHSEATTLE, WASHINGTON 98134(206) 318-1575THESE DRAWINGS AND THE PROJECT MANUAL ARE CONFIDENTIAL AND SHALL REMAIN THE SOLE PROPERTY OF STARBUCKS CORPORATION, WHICH IS THE OWNER OF THE COPYRIGHT IN THIS WORK. THEY SHALL NOT BE REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF STARBUCKS CORPORATION. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO EXPRESS DESIGN INTENT FOR A PROTOTYPICAL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO NOT REFLECT ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL HAVE ANY OBLIGATION NOR LIABILITY TO THE OTHER (EXCEPT STATED ABOVE) UNTIL A WRITTEN AGREEMENT IS FULLY EXECUTED BY BOTH PARTIES.STARBUCKS TEMPLATE VERSION: i2020-07-27STARBUCKSRSR. DESIGN MANAGER:DESIGN MANAGER:CHECKED BY:G00223871-06802-05-21HIGHWAY 99 & WATERLOO4426 EAST WATERLOO ROADSTOCKTON, CA 95215COUNTY OF SAN JOAQUIN7957JESSICA RAMOSJESSICA RAMOSVALERIOLIFE SAFETY ANDACC. PLANTOTAL OCC. LOAD:35 OCC.UNOCCUPIED: XXX SQ. FT.N/AQUEUE: 23 SQ. FT. / 5 SQ. FT. / OCC.4,6 OCC.BOH: 291 SQ. FT. / 200 SQ. FT. / OCC.1,4 OCC.PREP: 364 SQ. FT. / 200 SQ. FT. /1,8 OCC.RETAIL: 27 SQ. FT. / 60 SQ. FT. / OCC.0,45 OCC.CAFE SEATING: 398 SQ. FT. / 15 SQ. FT./ OCC. 26,5 OCC.OCCUPANCY CALCULATIONSNUMBER OF EXITS PROVIDED = 1NUMBER OF EXITS REQUIRED = 1EGRESS CALCULATIONSMEANS OF EGRESS NOTESHEALTH DEPT. PLAN NOTESKEYED NOTES1/4" = 1'-0"LIFE SAFETY & ACCESSIBILITY SCHEDULESRevision ScheduleRev Date By Description01-28-21 JGR FINAL REVIEW SET02-05-21 JGR PERMIT SET123LEGEND