Laserfiche WebLink
GENERAL NOTES1. G.C. SHALL VISIT THE SITE, REVIEW THEDRAWINGS AS SUBMITTED AND BECOME THOROUGHLY FAMILIAR WITH THE SITE CONDITIONS PRIOR TO CONSTRUCTION.2. G.C. SHALL CONSULT WITH STARBUCKS CONSTRUCTION MANAGER TO RESOLVE ANY CHANGES, OMISSIONS, OR PLAN DISCREPANCIES, PRIOR TO BIDDING OR CONSTRUCTION.3. ALL WORK SHALL BE PERFORMED IN COMPLIANCE WITH LOCAL, COUNTY, STATE AND FEDERAL CODES.4. G.C. SHALL VERIFY THE LOCATION OF ALL UTILITIES.5. G.C. TO VERIFY ALL DIMENSIONS, INCLUDING CLEARANCES REQUIRED BY OTHER TRADES AND NOTIFY STARBUCKS CONSTRUCTION MANAGER OF ANY DISCREPANCIES PRIOR TO PROCEEDING WITH THE WORK. ALL DIMENSIONS TO BE TAKEN FROM THE DESIGNATED DATUM POINT. DO NOT SCALE DRAWINGS.6. G.C. IS RESPONSIBLE FOR COORDINATING DELIVERY OF MATERIALS FROM STARBUCKS CONTRACTED THIRD PARTY LOGISTICS DISTRIBUTION SERVICES AND VENDOR DIRECT SHIPMENTS. 7. FOR THE PURPOSE OF THESE DOCUMENTS, TO “INSTALL” MEANS TO PROVIDE ALL FASTENERS, MISCELLANEOUS HARDWARE, BLOCKING, SERVICE CONNECTIONS, AND OTHER ITEMS REQUIRED FOR A COMPLETE AND OPERABLE INSTALLATION.8. ALL SUBSTITUTIONS MUST BE APPROVED BY STARBUCKS DESIGN MANAGER.9. VERIFY 30" MINIMUM CLEAR SPACE BELOW COUNTER FOR UNDERCOUNTER REFRIGERATION, NITRO GENERATOR AND BEVERAGE CONDUIT.10. INSURE 2" MINIMUM AIR GAP BETWEEN TOP OF REFRIGERATOR AND BOTTOM FACE OF COUNTERTOP.11. FONT/TAPS:• PLACE FONT ABOVE NITRO GENERATOR (PREFERRED).• REMOVE PLACEMENT, IF REQUIRED, PLACE FONT 8'-0" MAXIMUM FROM THE SIDE OF THE UNDERCOUNTER REFRIGERATION UNIT.• LOCATE FONT 13" O.C. FROM FRONT EDGE OF COUNTERTOP.12. NITRO GENERATOR:• INSURE 6" MINIMUM ON FRONT AND BACK SIDE OF GENERATOR FOR VENTILATION.DEMOLITION PLAN NOTES1. G.C. SHALL OBTAIN AND PAY FOR ALL PERMITS REQUIRED FOR THE DEMOLITION WORK.2. PERFORM DEMOLITION AS INDICATED AND AS REQUIRED TO ACCOMMODATE THE NEW WORK. DEMOLISH IN AN ORDERLY AND CAREFUL MANNER. WHERE DEMOLITION EXCEEDS THAT INDICATED, VERIFY SUCH DEMOLITION WITH ARCHITECT PRIOR TO PROCEEDING.3. WHEN UNANTICIPATED MECHANICAL, ELECTRICAL, STRUCTURAL OR OTHER ELEMENTS THAT CONFLICT WITH INTENDED FUNCTION OR DESIGN ARE ENCOUNTERED, INVESTIGATE AND ASCERTAIN THE NATURE AND EXTENT OF CONFLICT. PROMPTLY SUBMIT A WRITTEN REPORT TO OWNER. PERFORM NO FURTHER DEMOLITION IN SUCH AREAS UNLESS APPROVED.4. PROTECT ALL EXISTING FLOORS, WALLS, FINISHES, FURNITURE AND EQUIPMENT TO REMAIN DURING CONSTRUCTION. 5. PROTECT EXISTING STRUCTURAL MEMBERS.6. NOTIFY THE OWNER OF HAZARDOUS MATERIALS DISCOVERED DURING DEMOLITION OPERATIONS.7. EXCEPT WHERE NOTED OR SPECIFIED OTHERWISE, TAKE POSSESSION OF MATERIALS BEING DEMOLISHED AND IMMEDIATELY REMOVE FROM SITE. DEMOLISHED MATERIALS WHICH CANNOT BE RECYCLED OR REUSED SHALL BE DISPOSED OF AT A LEGAL DUMP SITE.8. CAREFULLY REMOVE, STORE AND PROTECT ALL MATERIALS AND COMPONENTS TO BE REUSED.9. WHERE REMOVAL OF MATERIALS INDICATED TO REMAIN IS NECESSARY TOFACILITATE NEW CONSTRUCTION, CAREFULLY REMOVE, STORE AND PROTECT SUCH MATERIALS FOR FUTURE REINSTALLATION.10. IF DAMAGE OCCURS TO EQUIPMENT, FINISHES OR ELEMENTS TO REMAIN, THE CONTRACTOR SHALL REPAIR AND/OR REPLACE TO LIKE NEW CONDITION.11. CAREFULLY REMOVE, STORE, PROTECT AND TURN OVER AS DIRECTED, MATERIALS AND COMPONENTS CLAIMED BY THE OWNER FOR SALVAGE. PRIOR TO DEMOLITION, CONTACT THE OWNER TO DETERMINE WHICH ITEMS WILL BE CLAIMED.12. OCCUPIED SPACES WHICH RECEIVE DEMOLITION WORK SHALL BE THOROUGHLY AND COMPLETELY CLEANED PRIOR TO THE OWNER’S DAILY OPERATIONS. CLEANING SHALL INCLUDE: VACUUMING, DUSTING, STAIN AND DIRT REMOVAL. 13.ELECTRICAL: REMOVE ELECTRICAL SYSTEM COMPONENTS AS INDICATED IN THE DRAWINGS.14.PLUMBING: ABANDONED UNDERSLAB PIPING SHALL BE CUT OFF FLUSH WITH THE FLOOR LINE AND SEALED. PATCH FLUSH WITH THE FLOOR. ABANDONED PIPING WHICH IS EXPOSED AND READILY ACCESSIBLE SHALL BE REMOVED. LEAVE ABANDONED PIPING WHICH IS CONCEALED IN EXISTING CONSTRUCTION TO REMAIN.PROPOSED FLOOR PLAN NOTES1. G.C. TO PROVIDE WALL BLOCKING AS NEEDED TO SUPPORT ANY WALL ATTACHMENT, FURNITURE, FIXTURE, EQUIPMENT OR ARTWORK.2. ALL EQUIPMENT AND CASEWORK INSTALLATION SHALL MEET NATIONAL SANITATION FOUNDATION STANDARDS OR EQUIVALENT. 3. ALL EQUIPMENT AND CABINETRY WILL BE FLUSH MOUNTED TO COUNTER, WALLS, FLOOR OR BE RAISED MIN. 6” TO ALLOW FOR CLEANING.4. CONFIRM ALL NECESSARY CLEARANCES PER EQUIPMENT CUT SHEETS.5. ALL FOOD STORAGE SHALL BE MIN. 6” A.F.F.6. G.C. SHALL REVIEW THE LOCATION, SIZE AND CONDITION OF EXISTING INFRASTRUCTURE AFFECTED BY OR ADJACENT TO NEW CONSTRUCTION. IF RELOCATION OR MODIFICATION OF (MECHANICAL, ELECTRICAL OR PLUMBING) IS NEEDED, NOTIFY THE STARBUCKS CONSTRUCTION MANAGER IMMEDIATELY.SHEET NUMBER:SHEET TITLE:SCALE:STORE #:PROJECT #:PROJECT NAME:PROJECT ADDRESS:C 2020 STARBUCKS COFFEE COMPANYRISSUE DATE:2401 UTAH AVENUE SOUTHSEATTLE, WASHINGTON 98134(206) 318-1575THESE DRAWINGS AND THE PROJECT MANUAL ARE CONFIDENTIAL AND SHALL REMAIN THE SOLE PROPERTY OF STARBUCKS CORPORATION, WHICH IS THE OWNER OF THE COPYRIGHT IN THIS WORK. THEY SHALL NOT BE REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF STARBUCKS CORPORATION. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO EXPRESS DESIGN INTENT FOR A PROTOTYPICAL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO NOT REFLECT ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL HAVE ANY OBLIGATION NOR LIABILITY TO THE OTHER (EXCEPT STATED ABOVE) UNTIL A WRITTEN AGREEMENT IS FULLY EXECUTED BY BOTH PARTIES.STARBUCKS TEMPLATE VERSION: i2020-07-27STARBUCKSRSR. DESIGN MANAGER:DESIGN MANAGER:CHECKED BY:I70123871-06802-05-21HIGHWAY 99 & WATERLOO4426 EAST WATERLOO ROADSTOCKTON, CA 95215COUNTY OF SAN JOAQUIN7957JESSICA RAMOSJESSICA RAMOSVALERIOGENERAL NOTESN/ARevision ScheduleRev Date By Description01-28-21 JGR FINAL REVIEW SET02-05-21 JGR PERMIT SET123