CONCRETE REPAIR NOTES1. PREPARED SURFACE SHALL BE SMOOTH AND FREE OF RIDGES AND IRREGULARITIES INCLUDING THOSE OCCURRING IN CONCRETE AND FROM MASTICS. 2. INITIAL CONCRETE SLAB PREPARATION: • REMOVE DIRT, OIL, SOAP, GREASE, MASTIC AND OTHER BOND-BREAKING CONTAMINANTS. • SURFACE SHALL BE SMOOTH AND FREE OF UNWANTED RIDGES FROM WITH MASTICS OR CONCRETE.3. SURFACE REPAIR:• FILL HOLES, SPALLS, CRACKS, VOIDS AND JOINTS AS RECOMMENDED BY THE SYSTEM MANUFACTURER WITH MINIMAL RESIDUE ON SURROUNDING SURFACE AND AS REQUIRED TO PROVIDE A SMOOTH, LEVEL AND EVEN SUBSTRATE.4. FINAL PREPARATION:• SURFACES TO BE TREATED SHALL BE CLEAN, DRY AND ABSORBENT.5. APPLICATION OF REPAIR AND RESURFACING MATERIALS:• INSTALL TROWELABLE UNDERLAYMENT AT LOCATIONS WHERE SLOPES ARE INDICATED AND AT OTHER LOCATIONS AS APPROPRIATE TO INSTALLATION CONDITIONS.• INSTALL SELF-LEVELING UNDERLAYMENT AT OTHER LOCATIONS AS NECESSARY TO CORRECT SLAB FLATNESS AND LEVELNESS.6. APPLICATION OF SEALER:• DO NOT APPLY SEALER TO SLABS OR PORTIONS OF SLABS INDICATED TO RECEIVE POLISHING SYSTEM OR A FINISHED FLOORING MATERIAL.• DO NOT APPLY SEALER TO SLABS OR PORTIONS OF SLABS INDICATED TO RECEIVE POLISHING SYSTEM OR A FINISHED FLOORING MATERIAL.• REMOVE ALL DIRT, DEBRIS, OR CURING COMPOUNDS USING SURFACE PREPARATION CLEANERS AS RECOMMENDED BY MANUFACTURER FOR CONDITIONS.• APPLY SINGLE COAT OF SEALER USING A LOW PRESSURE SPRAYER. APPLY IN SINGLE SATURATING APPLICATION. EVEN OUT PUDDLES WITH MICROFIBER APPLICATOR BEFORE MATERIAL HAS A CHANCE TO FULLY DRY. ALLOW TREATED SURFACES TO DRY AND REMOVE ANY DRIED POWDER RESIDUE.• APPLY SINGLE COAT OF SEALER USING A LOW PRESSURE SPRAYER. APPLY IN SINGLE SATURATING APPLICATION. EVEN OUT PUDDLES WITH MICROFIBER APPLICATOR BEFORE MATERIAL HAS A CHANCE TO FULLY DRY. ALLOW TREATED SURFACES TO DRY AND REMOVE ANY DRIED POWDER RESIDUE.TILE NOTESCLEAN SUBSTRATE SURFACES FREE OF GREASE, DIRT, DUST, ORGANIC IMPURITIES AND OTHER MATERIALS WHICH WOULD IMPAIR BOND.BACKING BOARD: “DUROCK BRAND CEMENT BOARD” BY USG (OR EQUAL)1. USE CEMENTITIOUS BACKING BOARD, EXCEPT WHERE GYPSUM BACKING BOARD IS INDICATED.2. SCREW ATTACH UNITS WITH 1 INCH LONG DRYWALL SCREWS SPACED 6 INCHES ON CENTER ALONG FRAMING. INSTALL FIBERGLASS REINFORCING TAPE AT JOINTS BETWEEN PANELS. COMPLETELY EMBED IN A THIN SET MORTAR BED. TROWEL MORTAR SMOOTH WITH ADJACENT SURFACES.SLAB LEVELING:1. PRIOR TO INSTALLATION OF THINSET FLOOR TILE, SUBSTRATE SHALL BE BROUGHT TO PLANE SURFACE WITH VARIATIONS NOT TO EXCEED 1/8 INCH IN 4 FEET (CUMULATIVE) AND ¼ INCH IN 10 FEET (NON-CUMULATIVE). SMOOTH ABRUPT CHANGES IN PLANE.2. USE THINSET MORTAR OR OTHER CEMENTITIOUS FILLER FOR SLAB LEVELING.CRACK ISOLATION: “DAL-SEAL CIS” BY DAL-TILE CORP. (OR EQUAL)WATER PROOF MEMBRANE: “DAL-SEAL TS” BY DA-TILE CORP. (OR EQUAL)1. INSTALL WATERPROOF MEMBRANES IN ACCORDANCE WITH MANUFACTURER’S INSTALLATION INSTRUCTIONS AND IN ACCORDANCE WITH ANSI A108.13.2. INSTALL WATERPROOF MEMBRANES AT ALL LOCATIONS WITH OCCUPIED SPACE BELOW OR WHEN REQUIRED BY LANDLORD IN A LEASED PROPERTY.3. AT SLAB ON GRADE LOCATIONS, INSTALL WATERPROOF MEMBRANES ONLY ALONG THE PERIMETER OF TILE AREAS. EXTEND THE MEMBRANE UP THE WALL AND A MINIMUM OF 12 INCHES OUT ONTO THE FLOOR SURFACE.4. AT ABOVE GRADE LOCATIONS, INSTALL WATERPROOF MEMBRANE COMPLETELY OVER FLOOR SURFACES INDICATED AND UP THE WALL.INTERIOR FLOOR APPLICATION:THINSET OVER CONCRETE SUBSTRATE AND CONCRETE SUBSTRATES WITH WATERPROOF OR CRACK ISOLATION MEMBRANE.• TCNA SYSTEM: F113 OR F122 AT WATERPROOFMEMBRANES• INSTALLATION STANDARD: ANSI A108.5• SETTING MATERIALS: THINSET MORTAR; 3/32 INCH MINIMUM THICKNESS• USE CEMENTITIOUS SANDED GROUT UNLESS INDICATED OTHERWISE.• USE EPOXY GROUT AT SERVICE AREAS BEHIND COUNTER.INTERIOR FLOOR APPLICATION: THICKSET OVER CONCRETE SUBSTRATE• TCNA SYSTEM: F112• INSTALLATION STANDARD: ANSI A108.1• BOND COAT: THINSET MORTAR OVER THICKSET MORTAR BED; 3/32 INCH MINIMUM THICKNESS• SLOPE MORTAR BED EVENLY TO FLOOR DRAINS.• USE CEMENTITIOUS SANDED GROUT UNLESS SPECIFIED OTHERWISE.• USE EPOXY GROUT AT SERVICE AREAS BEHIND COUNTER.WALL APPLICATION:GYPSUM BOARD SUBSTRATE• TCNA SYSTEM: SIMILAR TO W243• INSTALLATION STANDARD: ANSI A 108.5• SETTING MATERIALS: THINSET MORTAR• USE CONTENTIOUS SANDED GROUT UNLESS BEHIND BAR OR RESTROOM.WALL APPLICATION:TILE BACKING BOARD• TCNA SYSTEM: SIMILAR TO W244• INSTALLATION STANDARD: ANSI A108.5• SETTING MATERIALS: THINSET MORTAR• USE CEMENTITIOUS SANDED GROUT UNLESS BEHIND BAR OR RESTROOM.GROUTING:CEMENTITIOUS SANDED GROUT: “ULTRA/COLOR” BY MAPEI (OR EQUAL)CEMENTITIOUS UNSANDED GROUT: “KERACOLOR S” BY MAPEI (OR EQUAL)EPOXY GROUT: “KERAPOXY” BY MAPEI (OR EQUAL)1. COMPLY WITH PROVISIONS OF ANSI A108.102. APPLY GROUT RELEASE TO TILES PRIOR TO GROUTING. “ULTRA CARE GROUT RELEASE” BY MAPEI (OR EQUAL).SHEET NUMBER:SHEET TITLE:SCALE:STORE #:PROJECT #:PROJECT NAME:PROJECT ADDRESS:C 2020 STARBUCKS COFFEE COMPANYRISSUE DATE:2401 UTAH AVENUE SOUTHSEATTLE, WASHINGTON 98134(206) 318-1575THESE DRAWINGS AND THE PROJECT MANUAL ARE CONFIDENTIAL AND SHALL REMAIN THE SOLE PROPERTY OF STARBUCKS CORPORATION, WHICH IS THE OWNER OF THE COPYRIGHT IN THIS WORK. THEY SHALL NOT BE REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF STARBUCKS CORPORATION. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO EXPRESS DESIGN INTENT FOR A PROTOTYPICAL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO NOT REFLECT ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL HAVE ANY OBLIGATION NOR LIABILITY TO THE OTHER (EXCEPT STATED ABOVE) UNTIL A WRITTEN AGREEMENT IS FULLY EXECUTED BY BOTH PARTIES.STARBUCKS TEMPLATE VERSION: i2020-07-27STARBUCKSRSR. DESIGN MANAGER:DESIGN MANAGER:CHECKED BY:I70223871-06802-05-21HIGHWAY 99 & WATERLOO4426 EAST WATERLOO ROADSTOCKTON, CA 95215COUNTY OF SAN JOAQUIN7957JESSICA RAMOSJESSICA RAMOSVALERIOGENERAL NOTESRevision ScheduleRev Date By Description01-28-21 JGR FINAL REVIEW SET02-05-21 JGR PERMIT SET123N/A