(E) PANEL "A"(E) PANEL "B"4P 15749P 15749E 12618E 1623921IG56 61110789181010121314151615171712A-(23,25)A-(23,25)A-9A-13A-41A-41A-41A-9A-13Scale:1Power Plan 1/4" = 1'-0"SHEET NUMBER:SHEET TITLE:SCALE:STORE #:PROJECT #:PROJECT NAME:
<br />PROJECT ADDRESS:C 2020 STARBUCKS COFFEE COMPANYRISSUE DATE:2401 UTAH AVENUE SOUTHSEATTLE, WASHINGTON 98134(206) 318-1575THESE DRAWINGS AND THE PROJECT MANUALARE CONFIDENTIAL AND SHALL REMAIN THESOLE PROPERTY OF STARBUCKSCORPORATION, WHICH IS THE OWNER OF THECOPYRIGHT IN THIS WORK. THEY SHALL NOTBE REPRODUCED (IN WHOLE OR IN PART),SHARED WITH THIRD PARTIES OR USED IN ANYMANNER ON OTHER PROJECTS OREXTENSIONS TO THIS PROJECT WITHOUT THEPRIOR WRITTEN CONSENT OF STARBUCKSCORPORATION. THESE DRAWINGS ANDSPECIFICATIONS ARE INTENDED TO EXPRESSDESIGN INTENT FOR A PROTOTYPICALSTARBUCKS STORE (WHICH IS SUBJECT TOCHANGE AT ANYTIME) AND DO NOT REFLECTACTUAL SITE CONDITIONS. NEITHER PARTYSHALL HAVE ANY OBLIGATION NOR LIABILITY TOTHE OTHER (EXCEPT STATED ABOVE) UNTIL AWRITTEN AGREEMENT IS FULLY EXECUTED BYBOTH PARTIES.STARBUCKS TEMPLATE VERSION: i2020.10.23STARBUCKSRSR. DESIGN MANAGER:DESIGN MANAGER:CHECKED BY:Revision ScheduleRevDateByDescription01/28/21ACIESFINAL REVIEW SET400 N McCarthy Blvd.Copyright c 2021info@acies.netfx: (408) 522-5260ph: (408) 522-5255Suite 250, Milpitas, CA 95035ENGINEERINGHIGHWAY 99 & WATERLOO
<br />4426 EAST WATERLOO ROAD
<br />STOCKTON, CA 95215
<br />COUNTY OF SAN JOAQUIN23871-06801-28-217957JESSICA RAMOS02/05/21ACIESPERMIT SETA.FURNISH AND INSTALL A COMPLETE AND OPERATING SYSTEM.ALL ITEMS ARE NOT NECESSARILY SHOWN.B.ELECTRICAL CONTRACTOR RESPONSIBLE FOR SITEINVESTIGATION PRIOR TO START OF WORK TO REVEAL FULLSCOPE OF WORK.C.DIMENSIONS ARE TO FINISH FACE UNLESS OTHERWISE NOTED.D.REFER TO DETAIL SHEETS FOR EXACT LOCATIONS ANDMOUNTING HEIGHTS OF ELECTRICAL DEVICES.E.THE ELECTRICAL CONTRACTOR IS RESPONSIBLE FORCONFIRMING ALL VOLTAGE REQUIREMENTS ON ALLEQUIPMENT AND PROVIDING BUCK-BOOST TRANSFORMERS ASMAY BE NEEDED FOR PROPER OPERATION OF THEEQUIPMENT. ALL ARE NOT NECESSARILY INDICATED.F.ELECTRICAL CONTRACTOR SHALL COORDINATE WITHPLUMBING AND HEATING, VENTILATING, AND AIRCONDITIONING (HVAC) CONTRACTORS FOR ANY ADDITIONALEQUIPMENT NEEDING POWER.G.ANY EQUIPMENT NOTED AS ‘FUTURE’ SHALL BE PROVIDEDWITH APPROPRIATE RECEPTACLES AND WIRING TO ENABLEFUTURE OPERATION.H.GROUND FAULT CIRCUIT INTERRUPTER (GFCI) BREAKERS (NOTRECEPTACLES) SHALL BE UTILIZED WHERE REQUIRED BYCODE AND AT ANY FLOOR BOXES. PROVIDE DEDICATEDNEUTRAL WIRE FOR ALL THESE CIRCUITS.I.DISCONNECT AND REMOVE EXISTING ELECTRICAL DEVICESFOR EXISTING EQUIPMENT TO BE REMOVED. REROUTECONDUIT AND CONDUCTORS AROUN WALLS AND CEILINGAFFECTED BY REMODEL SO THAT DOWN STEAM DEVICES TOREMAIN STAY POWERED. REMOVE PORTIONS NO LONGERREQUIRED BACK TO NEAREST JUNCTION BOX OR TO SOURCE.TRACE ALL CIRCUITS IN THE AFFECTED AREAS PRIOR TOCONSTRUCTION AND RE-LABEL PANELS ACCORDINGLY.J.WORKING CLEARANCES SHALL BE MAINTAINED AND ARESUBJECT TO FIELD VERIFICATION PER NEC 110.16.K.GROUND-FAULT CIRCUIT-INTERRUPTER PROTECTION SHALLBEINSTALLED IN KITCHENS PER NEC 210.8(B)(2). SUBJECT TOFIELD VERIFICATION.L.GROUND-FAULT CIRCUIT-INTERRUPTER SHALL BE INSTALLEDIN A READILY ACCESSIBLE LOCATION PER NEC 210.8. SUBJECTTO FIELD VERIFICATION.M.SIGNS AND OUTLINE LIGHTING SYSTEM EQUIPMENT FOR WETLOCATION USE, OTHER THAN LISTED WATERTIGHT TYPE,SHALL BE WEATHERPROOF AND HAVE DRAIN HOLES, ASNECESSARY, IN ACCORDANCE WITH THE FOLLOWING: DRAINHOLES SHALL NOT BE LARGER THAN ½ INCH OR SMALLERTHAN ¼ INCH. EVERY LOW POINT OR ISOLATED SECTIONSHALL HAVE AT LEAST ONE DRAIN HOLE; DRAIN HOLES SHALLHAVE NO EXTERNAL OBSTRUCTIONS.N.CALIFORNIA ELECTRICAL CODE REQUIRES THE SERVICEEQUIPMENT'S MAIN DISCONNECT SWITCH AND FUSE, OR THECIRCUIT BREAKER, TO BE RATED AT THE AVAILABLESHORT-CIRCUIT CURRENT VALUE. ALL NEW NON-RESIDENTIAL,INDUSTRIAL AND MANUFACTURING ARE SUPPLIED BY ANINDIVIDUAL SERVICE DROP OR LATERAL RATED AT 225 AMPSOR MORE ARE REQUIRED TO HAVE A FAULT CURRENT LETTERPROVIDED BY PG&E OR THE ELECTRICAL SERVICE PROVIDERO.EQUIPMENT INTENDED TO BREAK CURRENT AT FAULT LEVELSSHALL HAVE AN INTERRUPTING RATING SUFFICIENT FOR THESYSTEM VOLTAGE AND THE CURRENT WHICH IS AVAILABLE ATTHE LINE TERMINALS OF THE EQUIPMENT. THERE ARE TWOWAYS TO SATISFY THE CODE REQUIREMENT: EITHER SERIESRATED OR FULLY RATED. ANY NEW BREAKERS ORSUB-PANELS MUST MEET THIS REQUIREMENT.P.GC TO NOTIFY SBUX CM + DM IF THERE ARE ANY (E) FLOOROUTLETS THAT NEED TO BE RELOCATED OR REMOVED.Q.EQUIPMENT REQUIRES CONNECTION TO THE BUILDINGELECTRICAL SYSTEM. FURNISH AND INSTALL ALL NECESSARYCONDUIT, WIRE, CONNECTIONS, RECEPTACLES ANDOVERCURRENT PROTECTION NECESSARY TO ENSURE THEEQUIPMENT FUNCTIONS PROPERLY AND COMPLIES WITH ALLAPPLICABLE LOCAL AND NATIONAL CODES. COORDINATEEQUIPMENT REQUIREMENTS WITH MANUFACTURER CUTSHEET PRIOR TO ROUGH-IN.R.ALL FRONT BAR J-BOXES AND OUTLETS SHALL BE SURFACEMOUNTED. PROVIDE CONDUITS AS NEEDED AND ONE (1)ADDITIONAL SPARE CONDUIT BETWEEN ALL J-BOXES FORFUTURE ELECTRICAL REQUIREMENTS. ALL J-BOXES SHALL BEPOSITIONED TO AVOID OBSTRUCTION OF ANY EQUIPMENTSUCH AS REFRIGERATORS AND DISHWASHERS.S.REFERENCE LANDLORD WORK LETTER FOR DIVISION OFELECTRICAL SCOPE OF WORK AND COORDINATE WITHSTARBUCKS CONSTRUCTION MANAGER.T.DATA CABLING LOCATED ABOVE HEAD SHALL BE PLENUM.U.DATA CABLING LOCATED UNDERGROUND SHALL BE RATEDFOR BELOW GROUND USE.POWER PLAN NOTESGENERAL NOTE1.REUSE EXISTING ELECTRICAL PANELS AND RECONNECT THERELOCATED LOADS AS REQUIRED. IF NEW LOADS ARE ADDED,USE AVAILABLE SPARE CIRCUITS.2.FIELD VERIFY THE RATINGS OF THE EXISTING PANELS ANDAVAILABLE SPARE CAPACITIES. IF NEW LOADS ARE ADDED TOTHE PANEL DO NOT EXCEED THE RATING OF THE PANELINCLUDING THE RATINGS OF THE UPSTREAM SERVINGFEEDER AND CIRCUIT BREAKER.3.ALL CIRCUIT NUMBERS SHOWN HERE ARE BASED ONPROVIDEDRECORD DRAWING. IF THE ACTUAL EXISTING CIRCUITNUMBERS ARE DIFFERENT THAN THE ONES SHOWN HERE, USETHE ACTUAL NUMBERS AND PROVIDE UPDATED TYPEWRITTENSCHEDULE IN ALL PANELS USED IN THIS PROJECT.SHEET NOTESPROVIDE CONNECTION FOR POS BANK. FIELD COORDINATE FOREXACT LOCATION AND REQUIREMENT. EXTEND EXISTING WIRINGFOR PREVIOUSLY USED THE SAME TYPE OF EQUIPMENT INEXISTING DEMO LOCATION TO THIS NEW LOCATION. CONNECTTO CIRCUIT AS SHOWN.PHONE LINE. FIELD COORDINATE EXACT LOCATION.PROVIDE CONNECTION FOR REGISTER. FIELD COORDINATEEXACT LOCATION AND REQUIREMENT. EXTEND EXISTING WIRINGFOR PREVIOUSLY USED THE SAME TYPE OF EQUIPMENT INEXISTING DEMO LOCATION TO THIS NEW LOCATION. CONNECTTO CIRCUIT AS SHOWN.EXISTING ELECTRICAL PANEL TO REMAIN. FIELD VERIFY EXACTLOCATION. PROVIDE UPDATED TYPEWRITTEN SCHEDULE UPONCOMPLETION OF THIS PROJECT. SEE PANEL SCHEDULE ONSHEET E-601. MAINTAIN 36" CLEARANCE IN FRONT OF PANELS.EXISTING POS TO BE RELOCATED HERE AND RE-CONNECTED TOEXISTING CIRCUIT PREVIOUSLY USED FOR SAME EQUIPMENT.ALL 120V RECEPTACLES IN WORKROOM AND BAR AREA SHALL BEGFCI RATED. AND ALL SINGLE PHASE RECEPTACLES RATED 150VOLTS TO GROUND OR LESS, 50A OR LESS AND THREE PHASERECEPTACLES RATED 150 VOLTS TO GROUND OR LESS, 100A ORLESS INSTALLED IN THE FOLLOWING LOCATIONS SHALL HAVEGROUND FAULT CIRCUIT INTERRUPTER PROTECTION FORPERSONNEL.EXISTING BREWER SOFT HEAT SERVER / SINGLE WARMINGSTAND TO BE RELOCATED HERE. FIELD COORDINATE EXACTLOCATION AND REQUIREMENT. IF POSSIBLE, EXTEND THEEXISTING CIRCUIT PREVIOUSLY USED FOR THE SAME LOAD INTHIS AREA. IF NO SUCH CIRCUIT IS AVAILABLE, PROVIDE NEWCONNECTION TO IT.EXISTING BREWER SOFT HEAT DUAL TO BE RELOCATED HERE.FIELD COORDINATE EXACT LOCATION AND REQUIREMENT. IFPOSSIBLE, EXTEND THE EXISTING CIRCUIT PREVIOUSLY USEDFOR THE SAME LOAD IN THIS AREA. IF NO SUCH CIRCUIT ISAVAILABLE, PROVIDE NEW CONNECTION TO IT.EXISTING GRINDER TO BE RELOCATED HERE. FIELD COORDINATEEXACT LOCATION AND REQUIREMENT. IF POSSIBLE, EXTEND THEEXISTING CIRCUIT PREVIOUSLY USED FOR THE SAME LOAD INTHIS AREA. IF NO SUCH CIRCUIT IS AVAILABLE, PROVIDE NEWCONNECTION TO IT.EXISTING UNDERCOUNTER FRIDGE TO BE RELOCATED HERE.FIELD COORDINATE EXACT LOCATION AND REQUIREMENT. IFPOSSIBLE, EXTEND THE EXISTING CIRCUIT PREVIOUSLY USEDFOR THE SAME LOAD IN THIS AREA. IF NO SUCH CIRCUIT ISAVAILABLE, PROVIDE NEW CONNECTION TO IT.EXISTING WARMING OVEN TO BE RELOCATED HERE. FIELDCOORDINATE EXACT LOCATION AND REQUIREMENT. IF POSSIBLE,EXTEND THE EXISTING CIRCUIT PREVIOUSLY USED FOR THESAME LOAD IN THIS AREA. IF NO SUCH CIRCUIT IS AVAILABLE,PROVIDE NEW CONNECTION TO IT.EXISTING ESPRESSO MACHINE TO BE RELOCATED HERE. FIELDCOORDINATE EXACT LOCATION AND REQUIREMENT. IF POSSIBLE,EXTEND THE EXISTING CIRCUIT PREVIOUSLY USED FOR THESAME LOAD IN THIS AREA. IF NO SUCH CIRCUIT IS AVAILABLE,PROVIDE NEW CONNECTION TO IT.EXISTING NITRO U/C EQUIPMENT TO BE RELOCATED HERE. FIELDCOORDINATE EXACT LOCATION AND REQUIREMENT. IF POSSIBLE,EXTEND THE EXISTING CIRCUIT PREVIOUSLY USED FOR THESAME LOAD IN THIS AREA. IF NO SUCH CIRCUIT IS AVAILABLE,PROVIDE NEW CONNECTION TO IT.PROVIDE CONNECTION FOR NEW FOOD CASE. FIELDCOORDINATE EXACT LOCATION AND REQUIREMENT. IF POSSIBLE,EXTEND THE EXISTING CIRCUIT PREVIOUSLY USED FOR THESAME LOAD IN THIS AREA. IF NO SUCH CIRCUIT IS AVAILABLE,PROVIDE NEW CONNECTION AND CONNECT TO CIRCUIT ASSHOWN.PROVIDE CONNECTION FOR NEW HOT WATER DISPENSER. FIELDCOORDINATE EXACT LOCATION AND REQUIREMENT. IF POSSIBLE,EXTEND THE EXISTING CIRCUIT PREVIOUSLY USED FOR THESAME LOAD IN THIS AREA. IF NO SUCH CIRCUIT IS AVAILABLE,PROVIDE NEW CONNECTION AND CONNECT TO CIRCUIT ASSHOWN.PROVIDE CONNECTION FOR NEW UNDERCOUNTER FRIDGE.FIELD COORDINATE EXACT LOCATION AND REQUIREMENT. IFPOSSIBLE, EXTEND THE EXISTING CIRCUIT PREVIOUSLY USEDFOR THE SAME LOAD IN THIS AREA. IF NO SUCH CIRCUIT ISAVAILABLE, PROVIDE NEW CONNECTION AND CONNECT TOCIRCUIT AS SHOWN.PROVIDE CONNECTION FOR FUTURE MOBILE ORDER, PAY &PRINT LABELER. FIELD COORDINATE EXACT LOCATION ANDREQUIREMENT.EXISTING NITRO GENERATOR TO BE RELOCATED HERE. FIELDCOORDINATE EXACT LOCATION AND REQUIREMENT. IF POSSIBLE,EXTEND THE EXISTING CIRCUIT PREVIOUSLY USED FOR THESAME LOAD IN THIS AREA. IF NO SUCH CIRCUIT IS AVAILABLE,PROVIDE NEW CONNECTION TO IT.123456789101112131415161718TGHTE-103ELECTRICALPOWER DESIGN
|