SHEET NUMBER:SHEET TITLE:SCALE:STORE #:PROJECT #:PROJECT NAME:
<br />PROJECT ADDRESS:C 2020 STARBUCKS COFFEE COMPANYRISSUE DATE:2401 UTAH AVENUE SOUTHSEATTLE, WASHINGTON 98134(206) 318-1575THESE DRAWINGS AND THE PROJECT MANUALARE CONFIDENTIAL AND SHALL REMAIN THESOLE PROPERTY OF STARBUCKSCORPORATION, WHICH IS THE OWNER OF THECOPYRIGHT IN THIS WORK. THEY SHALL NOTBE REPRODUCED (IN WHOLE OR IN PART),SHARED WITH THIRD PARTIES OR USED IN ANYMANNER ON OTHER PROJECTS OREXTENSIONS TO THIS PROJECT WITHOUT THEPRIOR WRITTEN CONSENT OF STARBUCKSCORPORATION. THESE DRAWINGS ANDSPECIFICATIONS ARE INTENDED TO EXPRESSDESIGN INTENT FOR A PROTOTYPICALSTARBUCKS STORE (WHICH IS SUBJECT TOCHANGE AT ANYTIME) AND DO NOT REFLECTACTUAL SITE CONDITIONS. NEITHER PARTYSHALL HAVE ANY OBLIGATION NOR LIABILITY TOTHE OTHER (EXCEPT STATED ABOVE) UNTIL AWRITTEN AGREEMENT IS FULLY EXECUTED BYBOTH PARTIES.STARBUCKS TEMPLATE VERSION: i2020.10.23STARBUCKSRSR. DESIGN MANAGER:DESIGN MANAGER:CHECKED BY:Revision ScheduleRevDateByDescription01/28/21ACIESFINAL REVIEW SET400 N McCarthy Blvd.Copyright c 2021info@acies.netfx: (408) 522-5260ph: (408) 522-5255Suite 250, Milpitas, CA 95035ENGINEERINGHIGHWAY 99 & WATERLOO
<br />4426 EAST WATERLOO ROAD
<br />STOCKTON, CA 95215
<br />COUNTY OF SAN JOAQUIN23871-06801-28-217957JESSICA RAMOS02/05/21ACIESPERMIT SETP-0003PLUMBING OUTLINESPECIFICATIONSN.T.S.PLUMBING1.1PROJECT CONDITIONSA.INTERRUPTION OF EXISTING SANITARY WASTE SERVICE: DO NOT INTERRUPTSERVICE TO FACILITIES OCCUPIED BY OWNER OR OTHERS UNLESS PERMITTEDUNDER THE FOLLOWING CONDITIONS AND THEN ONLY AFTER ARRANGING TOPROVIDE TEMPORARY SERVICE ACCORDING TO REQUIREMENTS INDICATED:1.NOTIFY CONSTRUCTION MANAGER NO FEWER THAN TWO DAYS IN ADVANCE OFPROPOSED INTERRUPTION OF SANITARY WASTE SERVICE.2.DO NOT PROCEED WITH INTERRUPTION OF SANITARY WASTE SERVICE WITHOUTCONSTRUCTION MANAGER'S WRITTEN PERMISSION.1.2MATERIALSA.HUB-AND-SPIGOT, SERVICE- CLASS, CAST-IRON SOIL PIPE AND FITTINGS BELOWGRADE WHERE REQUIRED BY LOCAL CODE.B.HUBLESS, CAST-IRON SOIL PIPE AND CISPI, CAST-IRON OR HUBLESS PIPINGCOUPLINGS.C.SOLID-WALL ORCELLULAR-CORE SCHEDULE 40 ABS PIPE WITH ABS SOCKETFITTINGS MAY BE USED ABOVE AND BELOW GRADE IF ALLOWED BY LOCAL CODE.D.SHIELDED, NONPRESSURE OR PRESSURETRANSITION COUPLINGS.E.UNION, FLANGE, FLANGE INSULATING KIT OR NIPPLEDIELECTRIC FITTINGS.F.PE-FILM ENCASEMENT FOR UNDERGROUND METAL PIPING.G.SCHEDULE 40 PVC PIPE WITH PVC SOCKET FITTING MAY BE USED BELOW GRADEIF ALLOWED BY LOCAL AUTHORITY.1.3ADHESIVESA.ADHESIVES SHALL NOT EXCEED A VOC CONTENT OF 510G/L FOR PVC AND 325G/L FOR ABS.END OF SECTION 221316SECTION 221316 - SANITARY WASTE AND VENT PIPINGPLUMBING1.1ACTION SUBMITTALSA.PRODUCT DATA: FOR EACH TYPE OF PRODUCT INDICATED. INCLUDE RATEDCAPACITIES, OPERATING CHARACTERISTICS, AND ACCESSORIES FOR THEFOLLOWING:1.FOG DISPOSAL SYSTEMS.2.GREASE INTERCEPTORS.3.GREASE REMOVAL DEVICES.4.WIRING DIAGRAMS: POWER, SIGNAL, AND CONTROL WIRING.1.2QUALITY ASSURANCEA.QUALITY STANDARD FOR BELOW GRADE PLASTIC PIPING: NSF 14.1.3PRODUCTSA.BACKWATER VALVES: HORIZONTAL- CAST IRON, DRAIN OUTLET OR HORIZONTAL-PLASTIC.B.CLEANOUTS:1.EXPOSED: COUNTERSUNK, COUNTERSUNK OR RAISED-HEAD, RAISED-HEAD,BRASS,CAST-IRON OR PLASTIC CLOSURE PLUG.2.CERAMIC TILE AND CARPETED FLOORS: SQUARE, ADJUSTABLE WITH NICKELBRONZE TOP.3.RESILIENT (VINYL) FLOOR: SQUARE, ADJUSTABLE, NICKEL BRONZE TOP WITHCOMPATIBLE FLANGE.4.WALL: ROUND, DEEP- CHROME-PLATED BRONZE,FLAT, CHROME-PLATEDBRASSOR STAINLESS-STEEL COVER PLATE WITH ROUND, CHROME PLATED,SCREW WALL ACCESS.C.FLOOR DRAINS:1.CAST-IRON FLOOR DRAINS, WITH STRAINER, BODY STYLE AND OPTIONS ASSPECIFIED IN PLUMBING SCHEDULE.2.PROVIDE TRAP PRIMER CONNECTIONS WHERE NEEDED PER CODE AND DESIGNREQUIREMENTS.D.TRENCH DRAINS TO BE AS SPECIFIED IN PLUMBING SCHEDULE.E.THROUGH-PENETRATION FIRESTOP ASSEMBLIES: LISTED AND LABELED ASSEMBLYOF SLEEVE AND STACK FITTING WITH FIRESTOPPING PLUG; WITH SPECIALCORROSION-RESISTANT COATING ON INTERIOR OF FITTINGS..F.MISCELLANEOUS SANITARY DRAINAGE PIPING SPECIALTIES:1.OPEN DRAINS, SHOP OR FIELD FABRICATE FROM SERVICE CLASS,HUB-AND-SPIGOT, CAST-IRON, SOIL-PIPE FITTINGS.2.CAST-IRON OR BRONZE DEEP-SEAL TRAPS.3.FLOOR-DRAIN, TRAP-SEAL PRIMER FITTINGS.4.AIR-GAP FITTINGS.5.COUNTERFLASHING-TYPE, CAST-IRON STACK FLASHING FITTINGS.6.CAST-IRON BODY VENT CAPS.7.FROST-RESISTANT VENT TERMINALS.8.EXPANSION JOINTS.1.4MANUFACTURED UNITSA.FOG DISPOSAL SYSTEMS AS SPECIFIED IN PLUMBING SCHEDULE.B.GREASE INTERCEPTORS AS SPECIFIED IN PLUMBING SCHEDULE.C.GREASE REMOVAL DEVICES AS SPECIFIED IN PLUMBING SCHEDULE.D.SOLIDS INTERCEPTORS: FACTORY-FABRICATED INTERCEPTOR MADE FORREMOVING AND RETAINING LINT OR SEDIMENT FROMWASTEWATER AS SPECIFIED IN PLUMBING SCHEDULE.END OF SECTION 221319SECTION 221319 - SANITARY WASTE PIPING SPECIALTIESPLUMBING1.1QUALITY ASSURANCEA.PERFORMANCE EFFICIENCY: ASHRAE/IESNA 90.1 AND ASHRAE 90.2.B.ASME COMPLIANCE: ASME BOILER AND PRESSURE VESSEL CODE: SECTION VIII,DIVISION 1.C.NSF COMPLIANCE: NSF 61 ANNEX G, "DRINKING WATER SYSTEM COMPONENTS -HEALTH EFFECTS."1.2COMMERCIAL, ELECTRIC, DOMESTIC-WATER HEATERSA.COMMERCIAL, LIGHT-DUTY, STORAGE, ELECTRIC, DOMESTIC-WATER HEATERS:STEEL, GLASS LINED, VERTICAL ARRANGEMENT WITH 150-PSIG (1035-KPA)PRESSURE RATING.B.SEE PLUMBING SCHEDULE FOR MAKE, MODEL, CAPACITY, AND RECOVERY RATE.1.3COMMERCIAL, GAS-FIRED, STORAGE, DOMESTIC-WATER HEATERSA.COMMERCIAL,ATMOSPHERIC], POWER-BURNER OR POWER-VENT, GAS-FIRED,STORAGE, DOMESTIC-WATER HEATERS: STEEL, GLASS LINED, VERTICALARRANGEMENT WITH 150-PSIG (1035-KPA) PRESSURE RATING CONDENSING TYPE.MINIMUM EFFICIENCY 90%. MEETS LOW NOx EMMISIONS PER CODEREQUIREMENTS.1.4DOMESTIC-WATER HEATER ACCESSORIESA.DRAIN PANS: CORROSION-RESISTANT METAL WITH RAISED EDGE.B.PIPING-TYPE HEAT TRAPS.C.HEAT-TRAP FITTINGS.D.GAS SHUTOFF VALVES.E.GAS PRESSURE REGULATORS: PRESSURE RATING TO MATCH GAS SUPPLYF.AUTOMATIC GAS VALVES.G.PRESSURE-REDUCING VALVES.H.COMBINATION TEMPERATURE-AND-PRESSURE RELIEF VALVES.I.PRESSURE RELIEF VALVES.J.VACUUM RELIEF VALVES.K.SHOCK ABSORBERS.L.DOMESTIC-WATER HEATER STANDS.M.DOMESTIC-WATER HEATER MOUNTING BRACKETS.N.EXPANSION TANK1.5ALL COMPONENTS OF DOMESTIC WATER SYSTEM TOUCHING DOMESTIC WATER ARELEAD FREE, INCLUDING ALL VALVES AND FITTINGS.END OF SECTION 223000SECTION 223000 – DOMESTIC-WATER HEATERSLLMP
|