SHEET NUMBER:SHEET TITLE:SCALE:STORE #:PROJECT #:PROJECT NAME:
<br />PROJECT ADDRESS:C 2020 STARBUCKS COFFEE COMPANYRISSUE DATE:2401 UTAH AVENUE SOUTHSEATTLE, WASHINGTON 98134(206) 318-1575THESE DRAWINGS AND THE PROJECT MANUALARE CONFIDENTIAL AND SHALL REMAIN THESOLE PROPERTY OF STARBUCKSCORPORATION, WHICH IS THE OWNER OF THECOPYRIGHT IN THIS WORK. THEY SHALL NOTBE REPRODUCED (IN WHOLE OR IN PART),SHARED WITH THIRD PARTIES OR USED IN ANYMANNER ON OTHER PROJECTS OREXTENSIONS TO THIS PROJECT WITHOUT THEPRIOR WRITTEN CONSENT OF STARBUCKSCORPORATION. THESE DRAWINGS ANDSPECIFICATIONS ARE INTENDED TO EXPRESSDESIGN INTENT FOR A PROTOTYPICALSTARBUCKS STORE (WHICH IS SUBJECT TOCHANGE AT ANYTIME) AND DO NOT REFLECTACTUAL SITE CONDITIONS. NEITHER PARTYSHALL HAVE ANY OBLIGATION NOR LIABILITY TOTHE OTHER (EXCEPT STATED ABOVE) UNTIL AWRITTEN AGREEMENT IS FULLY EXECUTED BYBOTH PARTIES.STARBUCKS TEMPLATE VERSION: i2020.10.23STARBUCKSRSR. DESIGN MANAGER:DESIGN MANAGER:CHECKED BY:Revision ScheduleRevDateByDescription01/28/21ACIESFINAL REVIEW SET400 N McCarthy Blvd.Copyright c 2021info@acies.netfx: (408) 522-5260ph: (408) 522-5255Suite 250, Milpitas, CA 95035ENGINEERINGHIGHWAY 99 & WATERLOO
<br />4426 EAST WATERLOO ROAD
<br />STOCKTON, CA 95215
<br />COUNTY OF SAN JOAQUIN23871-06801-28-217957JESSICA RAMOS02/05/21ACIESPERMIT SETP-0002PLUMBING OUTLINESPECIFICATIONSN.T.S.PLUMBING1.1REQUIREMENTSA.PROVIDE FOR EXPANSION OF PLUMBING PIPING IN ACCORDANCE WITH INDUSTRYSTANDARDS AND GOOD INSTALLATION PRACTICES.END OF SECTION 220516SECTION 220516 - EXPANSION FITTINGS AND LOOPS FOR PLUMBING PIPINGPLUMBING1.1SLEEVE-SEAL SYSTEMSA.FIELD-ASSEMBLED, MODULAR SEALING-ELEMENT UNIT FOR FILLING ANNULAR SPACEBETWEEN PIPING AND SLEEVE.1.SEALING ELEMENTS: EPDM RUBBER OR NBR.2.PRESSURE PLATES:CARBON STEEL, PLASTIC OR STAINLESS STEEL..3.CONNECTING BOLTS AND NUTS: CARBON STEEL WITH CORROSION-RESISTANTCOATING OR STAINLESS STEEL..1.2SLEEVE-SEAL FITTINGSA.MANUFACTURED PLASTIC, SLEEVE-TYPE, PLASTIC OR RUBBER WATERSTOP ASSEMBLYMADE FOR IMBEDDING IN CONCRETE SLAB OR WALL.1.3GROUTA.NONSHRINK, FACTORY PACKAGED.1.4SLEEVE AND SLEEVE-SEAL SCHEDULEA.EXTERIOR CONCRETE WALLS ABOVE GRADE:1.PIPING SMALLER THAN NPS 6 : CAST-IRON WALL SLEEVES,GALVANIZED-STEEL WALL SLEEVES OR GALVANIZED-STEEL-PIPE SLEEVES.SLEEVE-SEAL FITTINGS.B.EXTERIOR CONCRETE WALLS BELOW GRADE:1.PIPING SMALLER THAN NPS 6 : CAST-IRON WALL SLEEVES WITHSLEEVE-SEAL SYSTEM, GALVANIZED-STEEL WALL SLEEVES WITH SLEEVE-SEALSYSTEM,GALVANIZED-STEEL-PIPE SLEEVES WITH SLEEVE-SEAL SYSTEM ORSLEEVE-SEAL FITTINGS.C.CONCRETE SLABS-ON-GRADE:1.PIPING SMALLER THAN NPS 6 : CAST-IRON WALL SLEEVES WITHSLEEVE-SEAL SYSTEM, GALVANIZED-STEEL WALL SLEEVES WITH SLEEVE-SEALSYSTEM, GALVANIZED-STEEL-PIPE SLEEVES WITH SLEEVE-SEAL SYSTEM ORSLEEVE-SEAL FITTINGS.D.CONCRETE SLABS ABOVE GRADE:1.PIPING SMALLER THAN NPS 6: GALVANIZED-STEEL-PIPE SLEEVES,PVC-PIPE SLEEVES, STACK-SLEEVE FITTINGS, SLEEVE-SEAL FITTINGS,MOLDED-PE OR -PP SLEEVES OR MOLDED-PVC SLEEVES.E.INTERIOR PARTITIONS:1.PIPING SMALLER THAN NPS 6 : GALVANIZED-STEEL-PIPE SLEEVES ORPVC-PIPE SLEEVES.END OF SECTION 220517SECTION 220517 - SLEEVES AND SLEEVE SEALS FOR PLUMBING PIPINGPLUMBINGPRODUCTSA.LIQUID-IN-GLASS THERMOMETERS:1.COMPACT-STYLE, LIQUID-IN-GLASS THERMOMETERS:a.CASE:CAST ALUMINUM OR PLASTIC; 6-INCH (152-MM)SIZE.b.CASE FORM:BACK ANGLE OR STRAIGHT.c.TUBE: GLASS WITH MAGNIFYING LENS AND BLUE OR RED ORGANIC LIQUID.d.TUBE BACKGROUND: NONREFLECTIVE ALUMINUM WITH ETCHED SCALE INDEG F (DEG C) OR DEG F AND DEG C..B.THERMOWELLS:1.MATERIAL FOR USE WITH COPPER TUBING: CNR OR CUNI.2.MATERIAL FOR USE WITH STEEL PIPING: CRES OR CSA..3.TYPE: STEPPED SHANK UNLESS STRAIGHT OR TAPERED SHANK IS INDICATED.4.HEAT-TRANSFER MEDIUM: MIXTURE OF GRAPHITE AND GLYCERIN.C.PRESSURE GAGES:1.DIRECT-MOUNTED, METAL-CASE, DIAL-TYPE PRESSURE GAGES:a.CASE:LIQUID-FILLED, SEALED, OPEN-FRONT- PRESSURE RELIEF ORSOLID-FRONT- PRESSURE RELIEF TYPE (S); CASTALUMINUM OR DRAWN STEEL; 4-1/2-INCH (114-MM) OR 6-INCH (152-MM) DIAMETER.b.PRESSURE-ELEMENT ASSEMBLY: BOURDON TUBE UNLESS OTHERWISEINDICATED.c.PRESSURE CONNECTION: BRASS, WITH NPS 1/4 (DN 8), NPS 1/4 OR NPS 1/2 OR NPS 1/2 , ASME B1.20.1 PIPE THREADS ANDBOTTOM-OUTLET TYPE UNLESS BACK-OUTLET TYPE IS INDICATED.d.DIAL: NONREFLECTIVE ALUMINUM WITH ETCHED SCALE INPSI (KPA) OR PSIAND KPA.e.WINDOW: GLASS OR PLASTIC.f.RING: METAL,BRASS OR STAINLESS STEEL..g.ACCURACY: GRADE A, PLUS OR MINUS 1 PERCENT OF MIDDLE HALF OF,GRADE B, PLUS OR MINUS 2 PERCENT OF MIDDLE HALF OF,GRADE C, PLUSOR MINUS 3 PERCENT OF MIDDLE HALF OF OR GRADE D, PLUS OR MINUS 5PERCENT OF WHOLE SCALE RANGE.D.GAGE ATTACHMENTS:1.SNUBBERS: BRASS; WITH NPS 1/4 , NPS 1/4 OR NPS 1/2 ,NPS 1/2 , AND PISTON OR POROUS-METAL-TYPE SURGE-DAMPENINGDEVICE. INCLUDE EXTENSION FOR USE ON INSULATED PIPING.2.VALVES: BRASS BALL OR BRASS OR STAINLESS-STEEL NEEDLE, WITHNPS 1/4 , NPS 1/4 OR NPS 1/2 OR NPS 1/2, PIPETHREADS.END OF SECTION 220519SECTION SECTION 220519 - METERS AND GAGES FOR PLUMBING PIPINGPLUMBINGDOMESTIC HOT- AND COLD-WATER VALVESA.PIPE NPS 2 AND SMALLER:1.TWO-PIECE, BRASS BALL VALVES WITH FULL PORT, BRASS ORSTAINLESS-STEEL TRIM, AND LEAD FREE.2.THREE-PIECE, BRASS BALL VALVES WITH FULL PORT, BRASS,STAINLESS-STEEL TRIM, AND LEAD FREE.3.BRONZE SWING CHECK VALVES, CLASS 125, CLASS 150, BRONZE ORNONMETALLIC DISC WITHSOLDERED OR THREADED END CONNECTIONS,AND LEAD FREE.4.BRONZE GATE VALVES,CLASS 125, CLASS 150,NRS OR RS WITHSOLDERED ORTHREADED ENDS, AND LEAD FREE.END OF SECTION 220523SECTION 220523 - GENERAL DUTY VALVES FOR PLUMBING PIPINGPLUMBING1.1COMPONENTSA.METAL PIPE HANGERS AND SUPPORTS: FACTORY FABRICATED WITH GALVANIZEDCOATING, NON-METALLIC COATED FOR HANGERS IN DIRECT CONTACT WITH COPPERTUBING.B.THERMAL-HANGER SHIELD INSERTS: ASTM C 552, TYPE II CELLULAR GLASS.C.FASTENER SYSTEMS:POWDER-ACTUATED FASTENERS ANDMECHANICAL-EXPANSION ANCHORS.D.PIPE POSITIONING SYSTEMS: IAPMO PS 42, POSITIONING SYSTEM OF METAL BRACKETS,CLIPS, AND STRAPS.E.SUPPORTS FOR PEX PIPING SHALL BE MANUFACTURER APPROVED.F.COMPLY WITH ANSI/MSS SP-69 PIPE HANGERS AND SUPPORTS, SELECTION &APPLICATIONS.END OF SECTION 220529SECTION 220529 - HANGERS AND SUPPORTS FOR PLUMBING PIPINGPLUMBING1.1PRODUCTSA.EQUIPMENT LABELS:METAL OR PLASTIC.B.WARNING SIGNS AND LABELS: 1/16 INCH (1.6 MM) OR1/8 INCH (3.2 MM) THICK AND NOT LESS THAN 2-1/2 BY 3/4 INCH (64 BY 19 MM) SIZEWITH FASTENERS OR ADHESIVE. LETTER SIZE NOT LESS THAN 1/4 INCH (6.4 MM) FORNAME OF UNITS IF VIEWING DISTANCE IS LESS THAN 24 INCHES (600 MM), 1/2 INCH(13 MM) FOR VIEWING DISTANCES UP TO 72 INCHES (1830 MM), AND PROPORTIONATELYLARGER LETTERING FOR GREATER VIEWING DISTANCES. INCLUDE SECONDARYLETTERING TWO-THIRDS TO THREE-QUARTERS THE SIZE OF PRINCIPAL LETTERING.C.PIPE LABELS: PRETENSIONED OR SELF-ADHESIVE. LETTER SIZE NOT LESS THAN1/2 INCH (13 MM) FOR VIEWING DISTANCES UP TO 72 INCHES (1830 MM) ANDPROPORTIONATELY LARGER LETTERING FOR GREATER VIEWING DISTANCES.D.STENCILS: ALUMINUM, BRASS, FIBERBOARD, FIBERBOARD OR METAL.. LETTER SIZE NOT LESS THAN 1/2 INCH (13 MM) FOR VIEWINGDISTANCES UP TO 72 INCHES (1830 MM) AND PROPORTIONATELY LARGER LETTERINGFOR GREATER VIEWING DISTANCES.E.VALVE TAGS: BRASS, 0.032-INCH (0.8-MM), STAINLESS STEEL, 0.025-INCH (0.64-MM),ALUMINUM, 0.032-INCH (0.8-MM) OR ANODIZED ALUMINUM, 0.032-INCH (0.8-MM)MINIMUM THICKNESS.F.WARNING TAGS:3 BY 5-1/4 INCHES (75 BY 133 MM) MINIMUM OR APPROXIMATELY 4 BY 7INCHES (100 BY 178 MM)(INSERT SIZE);BRASS GROMMET AND WIRE,REINFORCED GROMMET AND WIRE OR STRING FASTENERS.END OF SECTION 220553SECTION 220553 - IDENTIFICATION FOR PLUMBING PIPING AND EQUIPMENTPLUMBING1.1QUALITY ASSURANCEA.SURFACE-BURNING CHARACTERISTICS: FLAME-SPREAD INDEX OF 25, ANDSMOKE-DEVELOPED INDEX OF 50 FOR INSULATION INSTALLED INDOORS,75, ANDSMOKE-DEVELOPED INDEX OF 150 FOR INSULATION INSTALLED OUTDOORS,ACCORDING TO ASTM E 84.1.2PIPING INSULATION SCHEDULE, GENERALA.ITEMS NOT INSULATED: UNLESS OTHERWISE INDICATED, DO NOT INSTALL INSULATIONON THE FOLLOWING:1.DRAINAGE PIPING LOCATED IN CRAWL SPACES.2.BELOW-GRADE DRAINAGE PIPING.3.CHROME-PLATED PIPES AND FITTINGS UNLESS THERE IS A POTENTIAL FORPERSONNEL INJURY.1.3INDOOR PIPING INSULATION SCHEDULEA.DOMESTIC COLD WATER: FLEXIBLE ELASTOMERIC, MINERAL-FIBER, PREFORMED PIPEINSULATION, TYPE I OR PHENOLIC.B.DOMESTIC HOT AND RECIRCULATED HOT WATER: FLEXIBLE ELASTOMERIC,MINERAL-FIBER, PREFORMED PIPE INSULATION, TYPE I OR PHENOLIC.C.STORMWATER AND OVERFLOW: 1/2” MINIMUM, CELLULAR GLASS, FLEXIBLEELASTOMERIC, MINERAL-FIBER, PREFORMED PIPE INSULATION, TYPE I, PHENOLICOR POLYOLEFIN.D.ROOF DRAIN AND OVERFLOW DRAIN BODIES: 1/2” MINIMUM, CELLULAR GLASS,FLEXIBLE ELASTOMERIC, MINERAL-FIBER, PREFORMED PIPE INSULATION, TYPE I,PHENOLIC OR POLYOLEFIN.E.EXPOSED SANITARY DRAINS, DOMESTIC WATER, AND DOMESTIC HOT WATER:FLEXIBLE ELASTOMERIC OR MINERAL-FIBER, PREFORMED PIPE INSULATION, TYPE I.F.EXPOSED FLOOR DRAIN BODIES, TRAPS, AND SANITARY DRAIN PIPING WITHIN10 FEET (3 M) OF DRAIN RECEIVING CONDENSATE ANDEQUIPMENT DRAIN WATER BELOW 60 DEG F (16 DEG C): 3/4” MINIMUM, FLEXIBLEELASTOMERIC, MINERAL-FIBER, PREFORMED PIPE INSULATION, TYPE I, PHENOLIC ORPOLYOLEFIN.G.HOT SERVICE DRAINS: CELLULAR GLASS OR MINERAL-FIBER, PREFORMED PIPE,TYPE I OR II.H. ICE BIN DRAIN: INSULATE DRAIN LINES WITH 1/2” (13MM) THICK SELF-SEALING,SECTIONAL, CLOSED CELL FOAM.I.DOMESTIC COLD AND HOT WATER IN CASEWORK AND BAR AREAS: FLEXIBLEELASTOMERIC, MINERAL-FIBER, PREFORMED PIPE INSULATION, TYPE I OR PHENOLIC.J.HVAC HOT AND CHILLED WATER PIPING INCLUDING LOW PRESSURE STEAM:1-1/2” (38MM) MINIMUM THICKNESS (OR THICKER PER LOCAL CODE) CELLULARGLASS OR MINERAL FIBER, PREFORMED PIPE, TYPE I OR II.1.4OUTDOOR, ABOVEGROUND PIPING INSULATION SCHEDULEA.DOMESTIC WATER PIPING: FLEXIBLE ELASTOMERIC, MINERAL-FIBER, PREFORMEDPIPE INSULATION, TYPE I OR PHENOLIC.B.HOT SERVICE DRAINS: CELLULAR GLASS OR MINERAL-FIBER, PREFORMED PIPE,TYPE I.C.HOT SERVICE VENTS: CELLULAR GLASS OR MINERAL-FIBER, PREFORMED PIPEINSULATION, TYPE II.1.5INDOOR, FIELD-APPLIED JACKET SCHEDULEA.PIPING, CONCEALED:ALUMINUM, PAINTED ALUMINUM OR STAINLESS STEEL.B.PIPING, EXPOSED: ALUMINUM, PAINTED ALUMINUM OR STAINLESS STEEL.1.6OUTDOOR, FIELD-APPLIED JACKET SCHEDULEA.PIPING, CONCEALED: ALUMINUM, PAINTED ALUMINUM OR STAINLESS STEEL.B.PIPING, EXPOSED:ALUMINUM, PAINTED ALUMINUM OR STAINLESS STEEL.END OF SECTION 220719SECTION 220719 - PLUMBING PIPING INSULATIONPLUMBING1.1INFORMATIONAL SUBMITTALSA.SYSTEM PURGING AND DISINFECTING ACTIVITIES REPORT.B.FIELD QUALITY-CONTROL REPORTS.1.2FIELD CONDITIONSA.INTERRUPTION OF EXISTING WATER SERVICE: DO NOT INTERRUPT WATERSERVICE TO FACILITIES OCCUPIED BY OWNER OR OTHERS UNLESS PERMITTEDUNDER THE FOLLOWING CONDITIONS AND THEN ONLY AFTER ARRANGING TOPROVIDE TEMPORARY WATER SERVICE ACCORDING TO REQUIREMENTSINDICATED:1.NOTIFY CONSTRUCTION MANAGER NO FEWER THAN TWO DAYS INADVANCE OF PROPOSED INTERRUPTION OF WATER SERVICE.2.DO NOT INTERRUPT WATER SERVICE WITHOUT CONSTRUCTION MANAGER'SWRITTEN PERMISSION.1.3PIPING MATERIALSA.POTABLE-WATER PIPING AND COMPONENTS SHALL COMPLY WITH NSF 14 ANDNSF 61 ANNEX G. PLASTIC PIPING COMPONENTS SHALL BE MARKED WITH"NSF-PW".1.4UNDER-BUILDING-SLAB, DOMESTIC WATER, BUILDING SERVICE PIPINGA.PIPE NPS 3 AND SMALLER:1.SOFT COPPER TUBE; WROUGHT-COPPER; AND BRAZED JOINTS.2.OTHER APPROVED PIPING WHEN SOIL IS CORROSIVE.3.PROVIDE TRACE WIRE FOR ALL PLASTIC UNDERGROUND PIPING SO THATUNDERGROUND PIPING MAY BE LOCATED IN THE FUTURE. TRACE WIRE:NO. 12, COPPER 600 V. THHN INSULATION.1.5UNDER-BUILDING-SLAB, DOMESTIC WATER PIPINGA.PIPE NPS 2 AND SMALLER:1.HARD OR SOFT COPPER TUBE; WROUGHT-COPPER; AND BRAZED JOINTS.2.OTHER APPROVED PIPING WHEN SOIL IS CORROSIVE.3.PROVIDE TRACE WIRE FOR ALL PLASTIC UNDERGROUND PIPING SO THATUNDERGROUND PIPING MAY BE LOCATED IN THE FUTURE. TRACE WIRE:NO. 12, COPPER 600 V. THHN INSULATION.1.6ABOVE GROUND DOMESTIC WATER PIPINGA.PIPE NPS 2 AND SMALLER:1.HARD COPPER TUBE; WROUGHT-COPPER; SOLDER-JOINT FITTINGS; ANDSOLDERED JOINTS WITH NON-LEAD, NON-ANTIMONY SOLDER.2.PEX TUBE, NPS 1 AND SMALLER; FITTINGS FOR PEX TUBE; AND WITHAPPROVED/MANUFACTURER COMPATIBLE JOINTS.3.PEX-AL-PEX TUBE, NPS 1 AND SMALLER; FITTINGS FOR PEX-AL-PEXTUBE; AND WITH APPROVED/MANUFACTURER COMPATIBLE JOINTS.1.7DOMESTIC WATER PIPE FITTINGS AND APPURTENANCES ARE LEAD FREE.END OF SECTION 221116SECTION 221116 - DOMESTIC WATER PIPINGPLUMBINGQUALITY ASSURANCEQUALITY STANDARDS: NSF 14 AND NSF 61.PRODUCTSVACUUM BREAKERS:1.PIPE-APPLIED, ATMOSPHERIC-TYPE VACUUM BREAKERS: ROUGH-BRONZE ORCHROME-PLATED FINISH.2.AIR-GAP FITTING: ASME A112.1.2, MATCHING BACKFLOW-PREVENTER CONNECTION.3.HOSE-CONNECTION VACUUM BREAKERS: CHROME- OR NICKEL-PLATED ORROUGH-BRONZE FINISH.4.PRESSURE VACUUM BREAKERS.BACKFLOW PREVENTERS:1.REDUCED-PRESSURE-PRINCIPLE BACKFLOW PREVENTERS:a.BODY: BRONZE FOR NPS 2 AND SMALLER.b.END CONNECTIONS: THREADED FOR NPS 2 AND SMALLER.c.CONFIGURATION: HORIZONTAL- STRAIGHT THROUGH,VERTICAL INLET,HORIZONTAL CENTER SECTION, AND VERTICAL OUTLET OR VERTICAL.d.LEAD FREE.2.DOUBLE-CHECK BACKFLOW-PREVENTION ASSEMBLIES:a.BODY: BRONZE FOR NPS 2 AND SMALLER.b.END CONNECTIONS: THREADED FOR NPS 2 AND SMALLER.c.CONFIGURATION:HORIZONTAL, STRAIGHT THROUGHd.LEAD FREE.3.HOSE-CONNECTION BACKFLOW PREVENTERS.WATER PRESSURE-REDUCING VALVES:1.WATER REGULATORS:a.BODY: BRONZE FOR NPS 2 AND SMALLER.b.VALVES FOR BOOSTER HEATER WATER SUPPLY: INCLUDE INTEGRAL BYPASS.c.END CONNECTIONS: THREADED FOR NPS 2 AND SMALLERTEMPERATURE-ACTUATED WATER MIXING VALVES:1.WATER-TEMPERATURE LIMITING DEVICES:a.CONNECTIONS: THREADED UNION INLETS AND OUTLET.b.FINISH: CHROME PLATED OR ROUGH BRONZE.2.PRIMARY, THERMOSTATIC, WATER MIXING VALVES:a.TYPE:EXPOSED MOUNTED OR CABINET TYPEb.CONNECTIONS: THREADED OR UNION INLETS AND OUTLET.c.FINISH: CHROME PLATED, POLISHED- CHROME PLATED OR ROUGH BRONZ.d.PIPING: CHROME PLATED OR COPPER..e.CABINET: RECESSED OR SURFACE MOUNTED.STRAINERS FOR DOMESTIC WATER PIPING:1.BODY: BRONZE FOR NPS 2 AND SMALLER; CAST IRON WITH INTERIORLINING AND EPOXY COATING FOR NPS 2-1/2 AND LARGER.2.CONNECTIONS: THREADED FOR NPS 2 AND SMALLER; FLANGED FOR NPS 2-1/2 AND LARGER.3.SCREEN: STAINLESS STEEL WITH ROUND PERFORATIONS UNLESS OTHERWISEINDICATED.4.DRAIN:PIPE PLUG, FACTORY-INSTALLED OR HOSE-END DRAIN VALVE.OUTLET BOXES:1.ICEMAKER OUTLET BOXES: ENAMELED-STEEL,EPOXY-PAINTED-STEELENAMELED-STEEL OR EPOXY-PAINTED-STEEL OR PLASTIC, PLASTIC ORSTAINLESS-STEEL BOX AND FACEPLATE.G.HOSE STATIONS:1.SINGLE-TEMPERATURE-WATER HOSE STATIONS:a.BODY: BRONZE WITH STAINLESS-STEEL WETTED PARTS.b.FINISH: ROUGH BRONZE,CHROME PLATED.c.MOUNTING: WALL, WITH REINFORCEMENT ORFLOOR, WITH STAINLESS-STEEL PEDESTAL.2.HOT- AND COLD-WATER HOSE STATIONS:a.TYPE FAUCET:BLENDING OR THERMOSTATIC MIXING VALVE.b.BODY: BRONZE WITH STAINLESS-STEEL WETTED PARTS.c.FINISH: ROUGH BRONZEOR CHROME PLATED.d.MOUNTING:WALL, WITH REINFORCEMENT ORFLOOR, WITH STAINLESS-STEEL PEDESTAL.3.COLD-WATER AND STEAM HOSE STATIONS:a.TYPE FAUCET:BLENDING OR THERMOSTATIC MIXING VALVE.b.BODY: BRONZE WITH STAINLESS-STEEL WETTED PARTS.c.FINISH: ROUGH BRONZE OR CHROME PLATED.d.MOUNTING: WALL, WITH REINFORCEMENT ORFLOOR, WITH STAINLESS-STEEL PEDESTAL.H.HOSE BIBBS:1.VACUUM BREAKER: INTEGRAL OR FIELD INSTALLATION.2.FINISH FOR SERVICE AREAS: ROUGH BRONZE OR CHROME OR NICKEL PLATED..3.OPERATION FOR SERVICE AREAS: WHEEL HANDLE OR OPERATING KEY..4.OPERATION FOR FINISHED ROOMS: WHEEL HANDLE OR OPERATING KEY..5.WALL FLANGE WITH EACH CHROME- OR NICKEL-PLATED HOSE BIBB.I.WALL HYDRANTS:1.NONFREEZE WALL HYDRANTS:a.OUTLET: CONCEALED OR EXPOSED..b.FINISH: POLISHED NICKEL BRONZE OR CHROME PLATED.2.NONFREEZE, HOT- AND COLD-WATER WALL HYDRANTS:a.OUTLET: CONCEALED.b.FINISH: POLISHED NICKEL BRONZE OR CHROME PLATED.3.MODERATE-CLIMATE WALL HYDRANTS:a.OUTLET: CONCEALED OR EXPOSED..b.FINISH: POLISHED NICKEL BRONZE OR CHROME PLATED.4.VACUUM BREAKER WALL HYDRANTS: LOOSE KEY,LOOSE KEY OR WHEEL HANDLE OR WHEEL HANDLE..J.GROUND HYDRANTS:1.BOX: STANDARD OR DEEP PATTERN WITH COVER.2.BOX AND COVER FINISH: ROUGH OR POLISHED NICKEL OR BRONZE.K.POST HYDRANTS:1.NONFREEZE, DRAINING-TYPE POST HYDRANTS.2.NONFREEZE, NONDRAINING-TYPE POST HYDRANTS.3.FREEZE-RESISTANT SANITARY YARD HYDRANTS: PLASTIC OR ZINC-PLATED STEELCANISTER.L.DRAIN VALVES:BALL-VALVE, GATE-VALVE OR STOP-AND-WASTE TYPE.M.WATER HAMMER ARRESTERS: METAL BELLOWS OR COPPER TUBE WITH PISTON..N.AIR VENTS: BOLTED OR WELDED CONSTRUCTION.O.TRAP-SEAL PRIMER VALVES: SUPPLY OR DRAINAGE TYPE.1.3MANUFACTURED UNITSA.TRAP-SEAL PRIMER SYSTEMS:1.CABINET: RECESSED- OR SURFACE-MOUNTED STEEL BOX WITH STAINLESS-STEELCOVER.2.NUMBER OUTLETS: FOUR, SIX OR EIGHT.1.4DOMESTIC WATER PIPE FITTINGS AND APPURTENANCES ARE LEAD FREE.END OF SECTION 221119SECTION 221119 - DOMESTIC WATER PIPING SPECIALTIESLLMP
|