Laserfiche WebLink
(E) 3/4" CWF5(R)BRBFP-212(N) 1/2" CWF141015210597MX-121111003815749BFP-1711(R)EMBFP-2171219277BFP-111311003815749BFP-1711(R)EMBFP-212619277BFP-1113910PLUMBING SUPPLY NOTESAFURNISH AND INSTALL A COMPLETE AND OPERATING SYSTEM. ALL ITEMSARE NOT NECESSARILY SHOWN.BPLUMBING CONTRACTOR RESPONSIBLE FOR SITE INVESTIGATION PRIORTO START OF WORK TO REVEAL FULL SCOPE OF WORK.CALL PLUMBING LINES TO BE ROUTED SUCH THAT THEY ARE NOT VISIBLETO CUSTOMER.DREFER TO MANUFACTURER SPECIFICATIONS FOR LOCATION OFCONNECTIONS UNLESS OTHERWISE NOTED.ECOORDINATE WITH ELECTRICAL CONTRACTOR FOR POWER CONNECTIONTO ALL PLUMBING EQUIPMENT.FREFERENCE WORK LETTER FOR DIVISION OF PLUMBING SCOPE OF WORKAND COORDINATE WITH STARBUCKS CONSTRUCTION MANAGER.GDIMENSIONS ARE TO FINISH FACE UNLESS OTHERWISE NOTED.HREFER TO DETAIL SHEETS FOR PLUMBING FITTINGS LOCATED INCASEWORK.ICOLD WATER SUPPLY LINES INSIDE CASEWORK AND BAR AREA TO BECOVERED WITH 1/2" (10MM) THICK SELF SEALING, SECTIONALCLOSED-CELL FOAM INSULATION. REFER TO SPECIFICATIONS FOR HOTWATER SUPPLY LINE INSULATION REQUIREMENTS.JGENERAL CONTRACTOR SHALL CONTACT WATER FILTRATION SUPPLIERTO COORDINATE SOW AN SCHEDULE PRIOR TO INSTALLATION OF WATERFILTRATION SYSTEM.KPIPING AND CONDUITS OF ALL TYPES (ELECTRICAL, WATER AND DRAINLINES) MUST BE CONCEALED WITHIN WALLS, FLOORS AND CEILINGS.SHEET NOTESEXTEND AS NEEDED AND CONNECT TO EXISTING CW / HW / CWF WATERPIPING. VERIFY IN FIELD EXACT LOCATION AND SIZE OF EXISTINGCONNECTED PIPING.PROVIDE 1/2" CW AND 1/2" HW PIPES DOWN IN WALL TO HAND SINK.INSTALL THERMOSTATIC MIXING VALVE AT ACCESSIBLE LOCATIONBELOW HAND SINK.PROVIDE 1/2" CW PIPE SUPPLY FOR RINSER WITH 3/8" PRESS FITTING.PROVIDE 1/2" CW AND 1/2" HW PIPES TO WORK SINK.PROVIDE 1/2" CWF PIPE CONNECTION TO RELOCATED COFFEE/TEABREWER, INSTALL SHUT-OFF IN CABINET AT 24" A.F.F. AND REDUCE TO3/8" AT UNIT.PROVIDE 1/2" CWF PIPE SUPPLY FOR ESPRESSO MACHINE. REDUCE TO3/8" AT ESPRESSO MACHINE CONNECTION.PROVIDE 1/2" CWF PIPE BRANCH TO SUPPLY FAUCET - HOT AND COLDWATER DISPENSER GOOSNECK.PROVIDE 1/2"CW PIPE CONNECTION BELOW COUNTER TO METEREDFAUCET FOR DIPPERWELL.PIPING ROUTED THRU LOW WALL.CAP EXISTING HOT AND COLD WATER PIPING IN WALL, THAT USED TOSERVE REMOVED HAND SINK.PROVIDE 1/2" DOUBLE CHECK VALVE BACKFLOW PREVENTER. WATTSSERIES 007 OR EQUAL. TO BE INSTALLED AT ACCESSIBLE LOCATIONS.PROVIDE 1/2" DUAL CHECK VALVE BACKFLOW PREVENTER, WATTS SD-3OR EQUAL. TO BE INSTALLED AT ACCESSIBLE LOCATIONS.123456789101112131415P-1101PLUMBINGSUPPLY PLAN 1/4" = 1'-0"SHEET NUMBER:SHEET TITLE:SCALE:STORE #:PROJECT #:PROJECT NAME: <br />PROJECT ADDRESS:C 2020 STARBUCKS COFFEE COMPANYRISSUE DATE:2401 UTAH AVENUE SOUTHSEATTLE, WASHINGTON 98134(206) 318-1575THESE DRAWINGS AND THE PROJECT MANUALARE CONFIDENTIAL AND SHALL REMAIN THESOLE PROPERTY OF STARBUCKSCORPORATION, WHICH IS THE OWNER OF THECOPYRIGHT IN THIS WORK. THEY SHALL NOTBE REPRODUCED (IN WHOLE OR IN PART),SHARED WITH THIRD PARTIES OR USED IN ANYMANNER ON OTHER PROJECTS OREXTENSIONS TO THIS PROJECT WITHOUT THEPRIOR WRITTEN CONSENT OF STARBUCKSCORPORATION. THESE DRAWINGS ANDSPECIFICATIONS ARE INTENDED TO EXPRESSDESIGN INTENT FOR A PROTOTYPICALSTARBUCKS STORE (WHICH IS SUBJECT TOCHANGE AT ANYTIME) AND DO NOT REFLECTACTUAL SITE CONDITIONS. NEITHER PARTYSHALL HAVE ANY OBLIGATION NOR LIABILITY TOTHE OTHER (EXCEPT STATED ABOVE) UNTIL AWRITTEN AGREEMENT IS FULLY EXECUTED BYBOTH PARTIES.STARBUCKS TEMPLATE VERSION: i2020.10.23STARBUCKSRSR. DESIGN MANAGER:DESIGN MANAGER:CHECKED BY:Revision ScheduleRevDateByDescription01/28/21ACIESFINAL REVIEW SET400 N McCarthy Blvd.Copyright c 2021info@acies.netfx: (408) 522-5260ph: (408) 522-5255Suite 250, Milpitas, CA 95035ENGINEERINGHIGHWAY 99 & WATERLOO <br />4426 EAST WATERLOO ROAD <br />STOCKTON, CA 95215 <br />COUNTY OF SAN JOAQUIN23871-06801-28-217957JESSICA RAMOS02/05/21ACIESPERMIT SETPlumbing supply planScale: 1/4" = 1'-0"1LLMP