SIDING SYSTEM, RTU
<br /> CONTINUOUS BEAD OF SEALANT LAP&SEAL SINGLE-PLY ROOFING GENERAL NOTES:
<br /> SEE WALL TYPE
<br /> MEMBRANE OVER SEAM PLATE
<br /> METAL CLOSURE STRIP AND GASKETED FASTENER @ 12"O.C. MAX
<br /> END FLASHING,TYP. (4)SIDES CONTINUOUS APPROVED 2X WOOD FRAMING 1. COORDINATE WITH PLUMBING, MECHANICAL, AND ELECTRICAL
<br /> DRAWINGS FOR LOCATION AND NUMBER OF OTHER ROOF
<br /> METAL FLASHING AND TERMINATION BAR EXTERIOR SHEATHING,
<br /> CONT. SEALANT-TYP. PER STRUCTURAL SINGLE-PLY ROOFING PENETRATIONS(IE: VENT STACKS VENT PIPES, CONDUIT
<br /> ROD&CLEVIS SINGLE-PLY MEMBRANE FLASHING OVER 1/4"DENSDECK PENETRATIONS, ETC.). FLASH ALL PENETRATIONS WEATHER TIGHT.
<br /> BY AWNING MANUFAC. INSULATED METAL CURB FULLY ADHERE SINGLE-PLY TAPERED RIGID INSULATION
<br /> O 2x P.T. BLOCKING, MEMBRANE TO SHEATHING 2. SLOPE ALL CRICKETS AS SHOWN AT A MINIMUM SLOPE OF 1/4"PER
<br /> 4"MIN. LAP OVER SEAM CANT STRIP ROOF SHEATHING PER FOOT FROM HORIZ. PLANE, UNLESS NOTED OTHERWISE.
<br /> AS REQUIRED �� 4"
<br /> BY AWNING MANUF. PLATE. FASTENER @ 12"O.C. X STRUCTURAL
<br /> Q 4"MIN. LAP OVER SEAM 4"MIN. LAP OVER SEAM PLATE 3. PROVIDE BUILT-UP TAPERED INSULATION ROOF CRICKETS AT ALL CURB v �J
<br /> 6x BLOCKING, WELDED SPLICE PLATE. FASTENER @ 12"O.C. LOCATIONS TO ALLOW POSITIVE DRAINAGE AND PREVENT PONDING.
<br /> PER STRUCT. °O WELDED SPLICE FASTENERS @ 12"O.C.
<br /> " SINGLE-PLY ROOFING,
<br /> CoSEDEING WALLSTYPE MECHANICALLY ATTACHED, OVER SINGLE-PLY ROOFING, 4. ALL METAL ROOF FLASHING DETAILS SHALL BE PER SMACNA AND
<br /> 4 1/4"DENSDECK OVER TAPERED 4 MECHANICALLY ATTACHED, MANUFACTURERS RECOMMENDATIONS AND REVIEWED BY THE
<br /> WEATHER RESISTIVE RIGID INSULATION OVER ROOF OVER 1/4"DENSDECK OVER ARCHITECT FOR DESIGN INTENT.
<br /> BARRIER(TYVEK OR EQ.) SHEATHING PER STRUCTURAL TAPERED RIGID INSULATION
<br /> u_ METAL CLOSURE STRIP AND OVER ROOF SHEATHING PER z 5. PROVIDE ROOF INSULATION SYSTEM BELOW ROOFING MEMBRANE, PER
<br /> Co Lo
<br /> END FLASHING,TYP. (4) _ STRUCTURAL M
<br /> SIDES N z z 4 _ THE ROOFING ASSEMBLIES SPECIFIED IN DIVISION 07 SECTIONS
<br /> METAL FLASHING AND CONT. N 'THERMOPLASTIC POLYOLEFIN ROOFING"AND"APPLIED
<br /> U
<br /> BACKER ROD&SEALANT- c� N N N FIREPROOFING".
<br /> 6. PROVIDE SUPPLEMENTAL INSULATION OVERBUILDS WHERE INDICATED
<br /> Cu PREFAB AWNING PROVIDE NAILER FOR PROVIDE NAILER FOR
<br /> ITLLL—
<br /> \x
<br /> 2x P.T. BLOCKING, CORNER SEAM PLATE CORNER SEAM PLATE FOR ROOF SLOPE CONTINUATION.
<br /> 71
<br /> AS REQUIRED
<br /> 311 1 BYAWNING MANUF.
<br /> 0
<br /> 6x BLOCKING,
<br /> PER STRUCT.
<br /> .CZ14 METAL SIDING BLOCKING DETAIL 3 SELF-FLASHING CURB 2 TYPICAL ROOF TO PARAPETri SINGLE PLY SYSTEM ASSEMBLYGNICH
<br /> .� SCALE: 1 1/2" = 1'-0" SCALE: 3" = 1'-0" SCALE: 3" = 1'-0" SCALE: 3" = 1'-0" ARCHITECTURE
<br /> a) ROOF HATCH, S T U D I O
<br /> DURO-LAST MEMBRANE PER PLAN MECHANICAL LINES Z AN OREGON LIMITED LIABILITY COMPANY
<br /> APPROVED DURO-LAST CAULK MECHANICAL UNIT,PER PLAN; CURB FLASHING
<br /> 0- DURO-LAST ROOF TRAK III ATTACH MECH.UNIT TO SLEEPER APPROVED DURO-LAST CAULK, N
<br /> WALKWAY PAD PER MFR'S.RECOMMENDATIONS. DURO-LAST APPROVED WATER MUST NOT BE ALLOWED
<br /> ICU DURO-LAST APPROVED SEALANT �TANT PLATES/FASTENERS TO POND W/IN PITCH PAN.
<br /> APPROVED INSULATION
<br /> a, DURO-LAST -FABRICATED ENSURE APPROVED DURO-LAST SEALANT 1001 SE SANDY BLVD, SUITE 100
<br /> DURO-LAST CURB FLASHING VAPOR BARRIER IS LEVEL W/TOP OF CURB AND COVER W/ Z PORTLAND, OR 97214
<br /> Q AIR Ay
<br /> VENT METAL CLEAT APPROVED DURO-LAST CAULK, SLOPE TO V. 503.552.9079
<br /> FIELD WELD, OUTSIDE OF PITCH PAN. F. 503.241.7055
<br /> .� MIN. 1 1/2"WIDE.
<br /> In DURO-LAST 1 1/4"ROOFING NAILS, �, WWW.GNICHARCH.COM
<br /> MEMBRANE SPACED 12"O.C., MAX. FIELD WELD,
<br /> U) MIN. 1 1/2"WIDE.
<br /> = COPING CAP, FIELD WELD,
<br /> FIELD WELD, WITH HEXHEAD SCREWS MIN. 1 1/2"WIDE. 3.202
<br /> MIN. 1 1/2"WIDE. AND NEOPRENE WASHER l?VINYL-COATED METAL PITCH PAN A
<br /> AT 24"O.C., MAX. W/DURO-LAST MEMBRANE SKIRT ` ERIK
<br /> DBL. TOP PLATE, --___ FILLER MATTHEWS
<br /> C 777
<br /> .0 PER PLAN (MINIMAL EXPANDING
<br /> SHEATHING, --- J SPRAY FOAM OR SIMILAR) NB C`37$4
<br /> o PER PLAN 1/4"DENSDECK APPROVED INSULATION, INSULATION, PER PLAN 04 30OS
<br /> €�EIVJ�IL DATE
<br /> o DURO-LAST ROOFING PRIME ROOF BOARD REPLACE INSULATION WITH
<br /> 1/4"DENSDECK MEMBRANE, PER PLAN DECK, WOOD BLOCKING IF SIZE OF VAPOR BARRIER DECK, 1/4"DENSDECK
<br /> v, INSULATION, PER PLAN PRIME ROOF BOARD PER STRUCTURAL MECHANICAL UNIT WILL 1/4"DENSDECK DECK, PER STRUCTURAL PRIME ROOF BOARD
<br /> OF C
<br /> Cz
<br /> VAPOR BARRIER DECK, PER STRUCTURAL PARAPET CAP W/ CONT. CLEAT - VAPOR BARRIER CRUSH INSULATION. PRIME ROOF BOARD PER STRUCTURAL MECHANICAL LINES PENETRATION -
<br /> 10 TWO-WAY
<br /> vi AIR VENT - DURO-LAST 9 DURO-LAST 8 MECHANICAL UNIT SLEEPER - DURO-LAST 7 ROOF ACCESS HATCH - DURO-LAST 6 DURO-LAST
<br /> U
<br /> SCALE: 1 1/2" = F-0" SCALE: 3" = F-0" SCALE: 3" = V-0" SCALE: 3" = F-0" SCALE: 3" = 1'-0"
<br /> Q
<br /> ICU_
<br /> RECTANGULAR
<br /> PENETRATION
<br /> 2
<br /> A4.0
<br /> w 1 1/4"ROOFING NAILS,
<br /> DURO LAST BEI
<br /> SPACED 6"O.C. DURO-LAST APPROVED BY OTHERS, OW Q
<br /> N R
<br /> ROOFING MATERIAL
<br /> SEALANT(1/2 TUBE MIN.) STACK FLASHINGCD
<br /> DURO-LAST CUSTOM-FABRICATED o FIRESTONE BUILDING PRODUCTS
<br /> o CURB FLASHING FIELD WELD, APPROVED DURO-LAST ULTRAPLYTPO MEMBRANE-60 MIL-WHITE CD
<br /> MIN. 1 1/2"WIDE. FASTENERS, AWNING DRAIN TO w i CV
<br /> `w DURO-LAST APPROVED MIN.ONE PER DRAIN DOWNSPOUTS, a PARAPET ROOF DRAIN W/OVERFLOW. O Co
<br /> PLATES/FASTENERS DURO LAST MEMBRANES DAYLIGHT TO DRAIN PARAPET ROOF TO STORM SEWER
<br /> ICU 1/4"DENSDECK DRIVE-THRU AISLE. o OR DAYLIGHT TO NEAREST LANDSCAPE.
<br /> o APPROVED INSULATION Z Z PRIME ROOF BOARD A4.0 DAYLIGHT OVERFLOW 18"ABOVE GRADE.
<br /> CD P-14
<br /> w VAPOR BARRIER PARAPET 3 ROOF DRAIN PARAPET 1 ROOF DRAIN W/OVERFLOW.
<br /> Co
<br /> W/OVERFLOW; CONNECT TO PARAPET 2 AND DRAIN TO O
<br /> FIELD WELD, DRAIN AND DAYLIGHTONTO 1/4" o AWNING DRAIN TO DOWNSPOUT, STORM SEWER OR DAYLIGHT
<br /> MIN. 1 1/2"WIDE. PARAPET ROOF. 5 TO TRENCH DRAIN,DAYLIGHT TO TO NEAREST LANDSCAPE. m
<br /> o DAYLIGHT OVERFLOW PER V-0" A8.0 DRIVE-AISLE AT FACE OF CURB DAYLIGHT OVERFLOW "'v
<br /> 18"ABOVE GRADE. o a 18"ABOVE GRADE. O N
<br /> m � W
<br /> U LL
<br /> C Q
<br /> 5q 13
<br /> o L EQ8A
<br /> A8.0 CRD.W/MECHANICAL; D' A8.0
<br /> BUILDING INSTALLED ON SLEEPERS. d z
<br /> PARAPET3 10 • •
<br /> =N DECK, INSULATION, PER PLAN PARAPET2 A8.0 N
<br /> PER STRUCTURAL 8 O Ln
<br /> VAPOR BARRIER O SLOPED RIGID �
<br /> m .rn ONE PAIR OF COMPOSITE EQ33 A4.0 INSULATION VALLEY z O
<br /> DRAIN RINGS(CDR)PLACED O ' U
<br /> o
<br /> E 1/4"DENSDECK DECK, AT THE BOTTOM OF THE 13 O `O v, O
<br /> PRIME ROOF BOARD PER STRUCTURAL STACK FLASHING 9 1 3'-4'x3'-a"R.O. 13 A4.0 U O
<br /> SILL @ 12"A.F.ROOF A4.0 A8 p 0 m V) V
<br /> L 5 CURB DETAIL - DURO-LAST 4 ROOF OVERFLOW - DURO-LAST ROOF MOUNTED O U
<br /> 13 HVAC EQUIP.; m
<br /> METALA8.0 COORD.W/ w • > cn
<br /> m CDSCALE: 3" = V-0" SCALE: 3" = V-0" AWNINGROOF MOUNTED MECH. 7 a
<br /> O U > }
<br /> HVAC EQUIP.; A4.0 j O 0 O
<br /> acl) BELOW y„ COORD.W/ BUILDING O
<br /> MECH.
<br /> EQ15A O
<br /> Cu PER 1'-0" C RD.W/MECH; PARAPET 1 CV
<br /> CLAMPING BOLT BLOCKING, CRICKET INSTALLED ON METAL
<br /> a DURO-LAST APPROVED / SLEEPERS.
<br /> AWNING
<br /> REFERENCE 14/A4.0 BELOW ISSUED FOR PERMIT:
<br /> SEALANT(1/2 TUBE MIN.) 13
<br /> CLAMPING RING DRAIN BODY PRE-FINISHED METAL FLASHING 2 A4.0 Ya"
<br /> Aa.o 8 PE 1R '0 01 . 13.2021
<br /> = DURO-LAST MEMBRANE, 1/4"DENSDECK 6'X6 X3/8 ALUMINUM PLATE A4.0
<br /> m MUST EXTEND BEYOND THE PRIME ROOF BOARD WITH (4) 5/8"O THRU BOLTS BUILDING 2
<br /> INSIDE OF THE CLAMPING RING. PARAPET2 CRICKET w A4.0
<br /> AWNING DRAIN
<br /> THE HOLE IN THE MEMBRANE 5/8"ZINC PLATED STEEL ROD To DOWNSPOUT, a
<br /> oQ MUST BE LARGER THAN AT 48"O.C. MAX TO TRENCH DRAIN,
<br /> _ 6"ALUMINUM CHANNEL, TYP., DAYLIGHT TO
<br /> THE DRAIN PIPE DIAMETER. REV: DATE: DESCRIPTION:
<br /> Q NEAREST LANDSCAPE
<br /> Cu PRIME& PAINT FINISH,
<br /> PRE-FINISHED PER MANUFACTURER
<br /> METAL FLASHING 13
<br /> -__ 4"X4"X3/8"AL. CLEVIS o A8.0
<br /> PLATE, W/5/8"0 BOLT w AWNING DRAIN TO DOWNSPOUT,
<br /> o TYP.CANOPY ROOF DRAIN TO DOWNSPOUTS; a TO TRENCH DRAIN,DAYLIGHT TO
<br /> 6' o LAG BOLT PER CONNECT TO STORM SEWER NEAREST LANDSCAPE
<br /> Cu TOO FACE IOF CURB GHT OOR LANUGH DS APE NCH DRAINRIDGE
<br /> STRUCTURAL
<br /> U d
<br /> N Q SHEET NAME:
<br /> �� P-14 P-14
<br /> B.O. CANOPY
<br /> O
<br /> Y DECK, RAIN GUTTER, WHERE OCCURS OVER + 10'-6"co
<br /> ROOF PLAN/ ROOF
<br /> 0 CuENTRY WALKS. SLOPE TO DOWNSPOUT DETAILS
<br /> PER STRUCTURAL CRICKET CRICKET
<br /> ICU INSULATION, PER PLAN & STORM SEWER SYSTEM .090 ALUMINUM SHEET DECK, CANOPY ROOF OVERFLOW,
<br /> 2X BLOCKING,AS REQUIRED
<br /> GHT T'PROUD
<br /> VAPOR BARRIER PRE-FINISHED METAL FLASHING ATTACH TO EA. ANGLE W/ 1/4" of OIFFTMATERIAL
<br /> m FILLER TEK SCREWS AT 9"O.C. MAX.
<br /> Co
<br /> MINIMAL EXPANDING FERNCO FITTING BLOCKING PER STRUCTURAL
<br /> ( SLOPE TO BUILDING
<br /> W SPRAY FOAM OR SIMILAR) PER PLAN SHEET NUMBER:
<br /> 3 TYPICAL 4" ROOF DRAIN - DURO-LAST
<br /> o � 2 SUSPENDED ALUMINUM AWNING DETAIL
<br /> Q ROOF PLANA4 . 0
<br /> Ez
<br /> a p SCALE: 3" = F-0" SCALE: 1" = F-0'
<br /> (D ICU SCALE: 1/4 = F-0"
<br /> 0' 2' 4'
<br /> ICU
<br /> 02020 DB Franchising USA,LLC
<br />
|