Laserfiche WebLink
IRRIGATION LEGEND <br /> \ \ SYMBOL MAKE MODEL DESCRIPTION U I j <br /> - - - - - - <br /> �;;� \\ \ W. EIGHT MILE ROAD - - - - <br /> _ \ RAINBIRD FSM-LXME 12 STATION CONTROLLER WITH ETC LX ET MANAGER CARTIDGE. INSTALL PER o <br /> i�zz ;\ 12 STATION MANUFACTURER'S SPECIFICATIONS. INSTALL INSIDE BUILDING UTILITY CLOSET. <br /> - --- --- --- -- --- -- --- --- -- <br /> i - -- - -- -- - - RAINBIRD XCZ-100- DRIP ASSEMBLY. PRESSURE REGULATING TO 40 PSI. SEE Z <br /> - - - -- --- -- --- -- --- --- --- --- -- <br /> / i� , \ _ PRB-COM DETAIL. Ln <br /> > <br /> 3 <br /> RAINBIRD 100-PEB 1" PEB PLASTIC IRRIGATION VALVE. SIZE PER PLAN. <br /> RAINBIRD 44RC 1" QUICK COUPLING VALVE. PLACE IN VALVE BOX. o <br /> - - _ - - - - w <br /> RAINBIRD 200-EFB-CP MANUAL LANDSCAPE IRRIGATION BRASS SHUT-OFF VALVE & PRESSURE M <br /> ------------------- PROJECT LIMITS - _ REGULATOR AS REQUIRED BY CA MWELO §492.7(a)(1)(E). INSTALL AFTER BFP & <br /> I — — METER. MAX WATER VELOCITY RECOMMENDED AT 7.5' PER SECOND. <br /> — <br /> JT G SD —S = �`—_ J 1" - DEDICATED LANDSCAPE WATER METER - CITY APPROVED AND AS PER CIVIL <br /> DRAWINGS & REQUIRED BY CA MWELO § 492.7(a)(1)(A). w <br /> RAINBIRD ETC-LX ET WEATHER SENSOR UNIT. INSTALL PER MANUFACTURER'S SPECS. 0° w <br /> RAINBIRD FS100P FLOW SMART MODULE - (SIZE AS PER VALVE SIZE) PVC T FLOW SENSOR, a <br /> i --- FLOW INSTALL PER MANUFACTURER'S SPECIFICATIONS (NO PULSE TRANSMITTER, <br /> I I o <br /> I <br /> I I <br /> I SENSOR N DECODER REQUIRED). <br /> z <br /> / <br /> i'� BACK FLOW PREVENTION VALVE <br /> PER CIVIL ENGINEERING PLANS. <br /> I <br /> (POC) POINT OF CONNECTION - CONTRACTOR TO FIELD VERIFY BEFORE INSTALLATION OF IRRIGATION MATERIALS. W� <br /> I 1 CLASS 200 PVC LATERAL LINE - SIZE AS SHOWN <br /> PRESSURE COMPENSATING POLYETHYLENE TUBING WITH EMITTERS. SIZE AS NEEDED. SEE DETAIL. <br /> I I � `- EMITTER DISTRIBUTION: <br /> I I IPM � <br /> I <br /> II I U� - I 1 PER 1 GALLON PLANT <br /> I I I � SD8� z <br /> O 2 PER 5 GALLON PLANT <br /> I _ I I I , � � <br /> 4 PER 15 GALLON PLANT. ALL TREES TO BE WATERED BY BUBBLERS PER PLAN. vS <br /> 1 I - - — w Q O <br /> W I I <br /> J II I I _ ------------- <br /> 0') <br /> ____ ----- ------- 2" SCHEDULE 40 IRRIGATION MAINLINE. Ln LO <br /> w Ln I <br /> ----_—____- ro <br /> cn rn <br /> I I _/ ______- SCHEDULE 40 PVC SLEEVE. SIZE AS NEEDED. O Q Ln <br /> -- __ __ I <br /> w 0 I <br /> STATION NUMBER :� — O <br /> i Q Lv <br /> LOI z � O(D <br /> Ir :w Q Wz <br /> it ------------ I ILJI VALVE SIZE J Q w w 0 <br /> III II I I I = Ln > = <br /> CD N J a_r^ I <br /> U) 1 i III �I I I • <br /> C— ■ I ; ; �� j HYDROZONE / STATION LEGEND - WATER CALCS IRRIGATION LEGEND z <br /> c I I I I I I U ^ 'VALVE# HYDROZONE WATER REQ WATER TYPE AREA(SF)FOR WATER CALCS NOZZLE/SYMBOL/G.P.M. <br /> III I I I Milestone <br /> I I w 1 1 I I I I I DRIP ZONE B 3A ....�...1 A LOW DRIP 1,094 SF M <br /> � MANLIF. MODEL O O Associates <br /> U III <br /> II I I 40 PSI / 3.3 GPM 1" I I I 2 ••""'• A LOW BUBBLER N/A- INCLUDED IN DRIP ZONE 7rz a ;,,e <br /> I I I I I��I RAINBIRD RWS-B-C 1401 <br /> I I I I I I II II 3 B LOW DRIP 1,752 SF 0.25 GPM (2 PER TREE) 000 TEL(530)�75 470STE0 ZFAX(3002, )755-4567CITY CA 9599 <br /> W u I <br /> ' II I I I SQUARE FOOTAGE SUB-TOTAL: 2,846 SF <br /> IIW <br /> III II ' � � V <br /> VALVE NUMBER CORRESPONDS TO STATION USED ON CONTROLLER. <br /> "'TREES WATERED BY BUBBLERS, TREE SQUARE FOOTAGE INCLUDED IN HYDROZONE AREA. <br /> IW ----- <br /> IRRIGATION RELATED NOTES: <br /> ILII I I o d- -� — <br /> ,, LANDSCAPE CAREFULLY DESIGNED AND PLANNED FOR THE EFFICIENT USE OF WATER. PLANTS HAVE BEEN GROUPED IN HYDROZONES OF SIMILAR 2 W <br /> I I I -------------- <br /> C-0 <br /> ----------- <br /> II I IOF <br /> ti <br /> � f I � w IT <br /> ' � WATER USE TO MAXIMIZE WATER USE EFFICIENCY AND EFFECTIVENESS. <br /> I I I <br /> oo <br /> I O <br /> T <br /> II I <br /> 1 % — <br /> i (POC I I �% ��� 1^, CONTRACTOR TO ENSURE STATIC WATER PRESSURE IS WITHIN THE REQUIRED DYNAMIC PRESSURE AS RECOMMENDED BY IRRIGATION cy e <br /> � i i W2- COMPONENTS MANUFACTURER. STATIC WATER PRESSURE, DYNAMIC OR OPERATING PRESSURE, AND FLOW READING OF THE WATER SUPPLY 2 cwy o <br /> I I <br /> CN <br /> I i SHALL BE MEASURED AT THE POC. PRESSURE AND FLOW MEASUREMENTS SHALL BE CONDUCTED AT INSTALLATION. CONTRACTOR TO v <br /> ilz ; rr nn O �l I I IMMEDIATELY CONTACT LANDSCAPE ARCHITECT IF PRESSURE IS NOT WITHIN MANUFACTURER'S RECOMMENDED RANGE FOR IRRIGATION q <br /> COMPONENTS. � <br /> CERTIFICATIONSTATEMENT: <br /> III I I 1 I r � O I I <br /> I HAVE COMPLIED WITH THE CRITERIA OF IRRIGATION EQUIPMENT: REMOTE CONTROL VALVES SHALL BE RAINBIRD PEB SERIES OR EQUAL - DVF SERIES MAY BE USED IN LOW VOLUME <br /> THE MUNICIPAL COD AND APPLIED THEM SITUATIONS. ALL VALVES WILL INCLUDE ISOLATION VALVES; NON-RISING STEM ALL BRASS GATE VALVE 'T' MODEL BY NIBCO. ALL DRIP <br /> FOR THE EFFICIENT SE OF WATER IN THE INSTALLATIONS SHALL HAVE PRESSURE REGULATING FILTER UNITS AND BE INSTALLED PER CITY STANDARD. NO ABOVE-GROUND SPRAY HEAD <br /> I I I I I I O i i LANDSCAPE DESIGN ,LAN. ,��/ SHALL BE USED. CT <br /> ►_ - I <br /> I I I I I J <br /> CONTRACTOR SHALL FIELD VERIFY POINT OF CONNECTION OF LANDSCAPE IRRIGATION WATER SOURCE PRIOR TO INSTALLATION OF ANY <br /> PRESSURE REGULATORS, MASTER SHUT-OFF VALVES, BACKFLOW PREVENTERS OR ANY OTHER IRRIGATION MATERIALS/SYSTEMS. PROVIDEC\1 CV <br /> oQ o <br /> BACKFLOW PREVENTER AT POINT OF CONNECTION AS PER PLANS - BY OTHERS. ALSO SUPPLY MANUAL SHUT-OFF VALVE FOR LANDSCAPE <br /> MAINLINE AFTER BACKFLOW�I III III <br /> I � PREVENTER. <br /> 2S4 SS4 -- ---- <br /> - ---- <br /> SS6 SS6 Ss� CALL BEFORE YOU DIG. PLAN IS DIAGRAMATIC, PLACE ALL IRRIGATION ELEMENTS IN LANDSCAPE AREAS. Pi's�r 17 <br /> w ------ ELECT <br /> , , , , , � ,-' - GAS ; <br /> 556 ISSN I -- CONTRACTOR - CALL BEFORE YOU DIG. <br /> SS6 <br /> S <br /> - ---- ---_ ss6 PURSUANT TO CA GOV CODE §4216 CALL ONE <br /> ' � � STATE MODEL WATER EFFICIENT LANDSCAPE ORDINANCE (MWELO) NOTES: � <br /> " �" z - ------- - '-- �� ' ' -;' s6 ,`� CALL CENTER (USA NORTH) AT LEAST 2 DAYS d Architect. If th <br /> ' Changes to the approved plans or field substitutions shall not be permitted without prior written approval from the Landscape e z <br /> C> BUT NOT MORE THAN 14 CALENDAR DAYS <br /> BEFORE YOU DIG. CALL 811 OR 1-800-227-2600. owner/contractor deviates from the approved plan without prior written approval they will be required to make any corrections, at their own expense, Q <br /> , <br /> �C to bring the landscape and irrigation into complaince with the approved plans and the State Model Water Efficient Landscape Ordinance. � <br /> N <br /> I I \\\\ 1. Contact the Planning Department of the City of Stockton, prior to backfilling irrigation trenches, to schedule irrigation inspection. Q <br /> ��y� I 2. An irrigation audit shall be completed by a Certified Landscape Irrigation Auditor, after installation and at regular intervals per MWELO. The W <br /> !,! i i ! ,' �� I audit shall be provided to the Planning Department for the City of Stockton for review and approval. Building Permit will not be signed off until audit W <br /> I <br /> II I I I TR <br /> BUBBRLEA&B 2/ 01 01 " � I � <br /> has been provided reviewed and approved. <br /> C) <br /> CN <br /> 40 PSI / 1 .5 GPM <br /> Uj <br /> w <br /> `\\ ETo = MADERA, CA 49.1; SUNSET WESTERN Mk' Z Z <br /> DRIP ZONE A 1 �� �� ► I W Q <br /> CLIMATE ZONES 14; WUCOLS REGION #2 v> <br /> 40PSI / 3.3GPM CENTRAL VALLEY i i i i i 00 <br /> J <br /> UTILITY NOTE: Q w <br /> TOTAL LANDSCAPE SQUARE FOOTAGE: 2,846 SF O I w Q Z <br /> TOTAL SITE AREA: 15,003 SF UTILITIES (UNDERGROUND AND/OR OVERHEAD), EXISTING AND PROPOSED ro N U, = Z O <br /> ,;\ �� I WERE NOT AVAILABLE AT THE TIME OF PREPARATION OF THESE DRAWINGS. �o N �, o � <br /> v w Q <br /> UTILITIES MUST BE PROVIDED AND LANDSCAPE CONSTRUCTION DOCUMENTS W w � o <br /> I I I SCALE: 1 " = 1 0'-0" ,� �� , SEE SHEET L-1 FOR GENERAL PLANTING AND o� � o (� <br /> II I I I i I � N ,;' ; I i IRRIGATION SPECIFICATIONS. MUST BE REVISED TO REFLECT UTILITY LOCATIONS PRIOR TO ANY Of 0 m N <br /> o II i I ,;' ,� �� LANDSCAPE CONSTRUCTION SERVICES INCLUDING: BIDDING, DIGGING, <br /> 0' 5' 10' 15' 20' %� ��' �� i I SEE SHEET L-5 FOR LANDSCAPE DETAILS. GRADING, OR INSTALLATION. <br /> L-4 <br /> J <br />