Laserfiche WebLink
J) 24" corded rubber tie attached to stake with 2 roofing \ 30-INCH LINEAR LENGTH OF <br /> nails. WIRE COILED <br /> 2\ 2" diameter x 8' long lodge pole pine stake. Place outside 4 � <br /> C2) WATERPROOF CONNECTION <br /> of rootball on predominately windward (south) side of 1 2 3 5 RAIN BIRD SPLICE-1 (1 OF 2) a <br /> tree. 3 ID TAG: RAIN BIRD VID SERIES <br /> 3\ Provide 3" berm around tree/shrub for water basin. Mulch <br /> plant well with 3" of 1/2" bark or recycled wood chips. ��� ��� 6 O VALVE BOX WITH COVER: <br /> RAIN BIRD VB-STD <br /> 1 ® Plant tree 1" above existing grade to allow for settlement. 1 3" MIN. 7 TOP OF MULCH o <br /> 2 g 5\ UJI <br /> Finish grade. 2 g 8 6 REMOTE CONTROL VALVE: w <br /> 9 6 Plastic Bio Barrier or Copper Impregnated Barrier must be 9 RAIN BIRD EFB-CP m <br /> installed if tree is to be planted within 5' of curb, sidewalk 9 L7 PVC SCH 80 NIPPLE (CLOSE) <br /> 4 or other rigid pavement. Install barrier linear along 4 4 w <br /> 3 hardscape to protect soil interface between soil and 3 3 DOS O 0 \ oo �g�o 10 � PVC SCH 40 ELL U <br /> 5 pavement, at a length of 7' on either side of tree trunk. <br /> 5 5 09 PVC SCH 80 NIPPLE <br /> 07 Backfill material - mix existing soil. - - - , - - - , , (LENGTH AS REQUIRED) <br /> Place three (3) time release fertilizer tablets in each - r = 10 BRICK (1 OF 4) w <br /> 15-gallon tree pit. (1) per 1-Gallon, (2) per 5-Gallon. 7 7 - m <br /> o „ o = 11 PVC MAINLINE PIPE ZUJI <br /> a <br /> 7 (:9) 5' Minimum setback to roadside obstructions, or City or 8 �o 6 o 11 8 9 8 13 14 8 11 12 PVC SCH 40 TEE OR ELL o <br /> County Standards. r � <br /> CS <br /> _ 8 - LFi�� 13 PVC SCH 40 MALE ADAPTER z <br /> 10 Trees shall be located so they are Y-0" (minimum) clear of 1 � � � III III � '- 8 '8 - <br /> 14 <br /> all pedestrian pathways and rigid pavement or ground 2X Rootball 3.0-INCH MINIMUM DEPTH OF <br /> 2x Rootball cover (i.e., concrete sidewalks, brick pavers set in mortar, 2x Rootball 3/4-INCH WASHED GRAVEL <br /> A <br /> TREE PLANTING etc.) ROOT BARRIER DETAIL B SHRUB PLANTING W� <br /> c RAINBIRD 200-EFB-CP Z <br /> NOT TO SCALE NOT TO SCALE ELECTRIC REMOTE VALVE W/ MANUAL FUNCTION N.T.S. <br /> 4 2 3 LATERAL c3 <br /> z <br /> MAINLINE, LATERAL & WIRINGU^ vi >- <br /> `n <br /> = INTO COMMON TRENCH MAINLINE PIPE OR LATERAL LATERAL PIPE AND J > � M <br /> SOLVENT WELDED � � 1 <br /> /SAA/SAA/� � 1 ROOT WATERING SYSTEM: DEDICATED CONDUIT <br /> RAIN BIRD RWS-B-C-1401 (INCLUDES PLASTIC PIPE < O Q Ln <br /> i RETAINER, 36" (91,4 CM) TUBE, 0.25 GPM (0,95 L/M) BUBBLER & INTEGRATED N w U I <br /> 1 T ") CHECK VALVE, 4" (10,2 CM) GRATE, VERSATILE SWING ASSEMBLY ' w Q o <br /> 11LOUj <br /> WITH 1/2" (1 ,3 CM) M NPT INLET) \ z o <br /> \ \ Q : z <br /> O BUBBLER: RAIN BIRD 1401 0.25 GPM (0,95 L/M) (INCLUDED) _ <br /> w w <br /> O3 FINISH GRADE/TOP OF MULCH _ Z cDLn _j oz <br /> N � � / � N J 0- <br /> 4) <br /> 5 O 4" (10,2 CM) LOCKING GRATE (INCLUDED)1 11111111111111111110 \ O • <br /> • <br /> 5\ 12" (30,5 CM) SWING ASSEMBLY (INCLUDED) \ M Milestone <br /> 11111111 1/2" 1 3 CM MALE NPT INLET INCLUDED O Associates <br /> 1000 LINCOLN 75 STS.H2O2, (530 CITU,56 95991 <br /> O PVC SCH 40 TEE OR EL TEL(530,755-47x0 FAX(530)755-4567 <br /> 8 PVC OR POLYETHYLENE LATERAL PIPE ALL LOW—VOLTAGE WIRING \� <br /> 4" (10,2 CM) WIDE X 36" (91,4 CM) LONG RIGID BASKET WEAVE SHALL BE HOUSED IN A <br /> 9 DEDICATED CONDUIT // / <br /> CANISTER (INCLUDED) V�^) <br /> 10 OPTIONAL SOCK (RWS-SOCK) FOR SANDY SOILS LOW VOLTAGE WIRING Z <br /> 7 6 g TAPED TO MAINLINE, SEE NOTE, <br /> NOTES: <br /> NOTES: 1 , BURIES DEPTH FOR SLEEVES BELOW FINISH GRADE ARE AS FOLLOWS: O <br /> 11111111111111111110 1 . 4" (10,2 CM) GRATE IS ALSO AVAILABLE IN PURPLE (RWS-GRATE-P). 42 INCH MINIMUM UNDER THOROUGHFARE AND STREETS U °8 <br /> 11111111 g 2. INSTALL PRODUCT SO THAT THE GRATE IS EVEN WITH FINISH GRADE OR TOP OF MULCH. 24 INCH MINIMUM UNDER PLANTER AREA <br /> v <br /> 24 INCH MINIMUM UNDER PARKING EOT � � e <br /> 3. OPTIONAL SAND SOCK (RWS-SOCK) IS 34" (86,4 CM) IN LENGTH TO COVER MESH BASKET 18 INCH MINIMUM UNDER SIDEWALK <br /> MIMI AREA. 2. ALL SLEEVE BELOW HARDSCAPE SHALL EXTEND 18 INCHES BEYOND HARD SURFACE ENDGES. <br /> 4. WHEN INSTALLING IN EXTREMELY HARD OR CLAY SOILS, ADD 3/4 (1,9 CM) GRAVEL 3. MAINLINE SHALL HAVE MINIMUM COVER OF 24 INCHES, LATERAL SHALL HAVE MINIMUM COVER OF 18 INCHES. Q w <br /> UNDER AND AROUND THE UNIT TO ALLOW FASTER WATER INFILTRATION AND ROOT 4. SCHEDULE 40 PVC FOR MAINLINE 2 INCHES OR SMALLER, 2 <br /> 10 PENETRATION. 5. TRENCH BACKFILL SHALL BE NATIVE MATERIAL, COMPACT TO 90% MINIMUM, RELATIVE COMPACTION, U U <br /> 5. ONCE RWS HAS BEEN INSTALLED FILL THE BASKET WITH PEA GRAVEL BEFORE LOCKING 6. IF APPROVED IN WRITING FROM THE CITY OR COUNTY, CONTROL WIRE MAY BE INSTALLED WITHOUT VJ q <br /> LID. CONDUIT. INSTEAD, RUN WIRING BENEATH MAINLINE, TAPE AND BUNDLE AT 10 FOOT INTERVALS TIE 0 <br /> A 24 INCH LOOP IN ALL WIRING AT CHANGES OF DIRECTION OF 30 INCHES OR GREATER. UNTIE AFTER <br /> ALL CONNECTIONS HAVE BEEN MADE. 7 <br /> DEEP ROOT WATERING SYSTEM - RAINBIRD RWS-B-C-1401 IRRIGATION TRENCHING Q <br /> D NOT TO SCALE E NOT TO SCALE J <br /> � oQo <br /> U z � � cv a; 6 <br /> 1\ MULCH <br /> � � � a o <br /> Diagram : ESP-LXMEF 1\ Finish Grade. 1" ball valve. Class 200 lateral pipe, 12 3/4" to 5/8"Adapter. �r <br /> w 2 3 4 5 O FLUSH CAP FOR EASY FIT COMPRESSION FITTINGS: <br /> 2 Valve box with 6 ID to size per plan. <br /> � POTABLE:RAIN BIRD MDCFCAP <br /> \ g. 13 5/8" Polyethylene drip I7 <br /> M PE-39 Cagle to Controller //To flow"-"on cover. <br /> 10 Flow Smart Module linear length of Remote control valve. 10 Mainline pipe. pipe. COVER W/3" <br /> Q 6 7 8 9 3 EASY FIT COUPLING: RAIN BIRD MDCFCOUP wire, <br /> „ BARK. <br /> \ ® Plating 11 3 minimum depth of <br /> wire, coiled. Pressure regulating 3/4 inch washed ravel. 14 PVC Mainline. (Length quick check basket filter. g g <br /> 4\ SUBTERRANEAN EMITTER BOX: RAIN BIRD SEB 7XB � i4! Waterproof q as required) � J <br /> To flow"+"on 7 <br /> 01 Flow smart Module connection: Dry Z <br /> 5 /2 POLYETHYLENE TUBING: RAIN BIRD XF BLANK splice connectors 2 3 4 6 17 15 1 GPH XERIBUG Q Q <br /> TUBING s�r2o 15 XB-10PC Emitter. <br /> sprue Kit with sealant. 7 L, � W <br /> FINISH GRADE 8 16 PVC Sch 80 ELL. W <br /> 2"ABOVE F.G. �_ 1 41 Q Z <br /> 07 <br /> g PVC EXHAUST HEADER 17� 1/4" Distribution <br /> bi3 Z <br /> tTung w/stake �,slack Red � �, U <br /> Q <br /> 000000 00°0000000 o O PVC SCH 40 TEE OR EL VI N from emitter at root W W C) <br /> 09 BARB X MALE FITTING: RAIN BIRD XFF—MA FITTING Ro16 zone, then 36" O.C. o <br /> te.Mica can�run ,r'Y�7 <br /> up 4a 0'of N <br /> (TYPICAL) AMM Wre- w <br /> 10 Flow sensor 14 0 0 O 0 ��`' Z CO <br /> ON SURFACE DRIPUNF. RAIN BIRD XF SERIES °00000 000x '\ 0O 0) w _ Z <br /> NOTE: DRIPEINE -- —� ° 13 to Q 0 <br /> 1. ALLOW A MINIMUM OF 18-INCHES OF DRIPLINE TUBING IN 11 POTABLE: XFCV DRIPLINE L_ __? 9 o U <br /> \ - 11 12 0� < � °' W <br /> VALVE BOX IN ORDER TO DIRECT FLUSHED WATER 5; i <br /> � Q W <br /> OUTSIDE VALVE BOX. 12 BRICK (1 OF 2) 10 � o (D o U <br /> 3—INCH MINIMUM DEPTH OF 3/4" WASHED GRAVEL o o <br /> XFCV ON-SURFACE DRIPEINE FLUSH POINT IRRIGATION FLOW SENSOR INSTALLATION DRIP ASSEMBLY AND EMITTERS - 30PSI ww � 00 0 <br /> F W/ EASY FIT COMPRESSION FITTINGS NOT TO SCALEG NOT TO SCALE H NOT TO SCALE 0-o m N Z <br /> Q <br /> J <br /> L-5 <br />