Laserfiche WebLink
REVISIONS <br /> TENTATIVE IMPROVEMENT PLANS FOR: REV DATE DESCRIPTION <br /> PRIME MARKET 234 WEST YOSEMITE AVE MANTECA CA 95336 <br /> 4 <br /> W . J(11 78U2 �� + <br /> EXISTING CONDITIONS: 921-6" 2019 CALIFORNIA EXISTING BUILDING �I Expires <br /> W <br /> EXISTING VACANT BUILDING(2,650ft2)WITHIN A(7,800W)BUILDING LOCATEDCODE a' <br /> 82'-6" <br /> AT 234 WEST YOSEMITE AVENUE,CITY OF MANTECA,CA 95336, (LAT: 37.79720, . " <br /> LONG: -121.21859)ELEV: 37',WITHIN PARCEL APN: 219-400-01,REVISED MAP OF 55'-6" 13'-6" 11'-6" 9'-6" CHAPTER 1: SCOPE AND ADMINISTRATION ' <br /> NORTH MANTECA,BOOK 219,PAGE 40,LOT#1,BLDG#7 DIVISION I-CALIFORNIA ADMINISTRATION <br /> ZONING: CENTRAL BUSINESS OVERLAY ZONE 1 (CBD). EXISTING <br /> 6'-0" 50'-0" RESTROOM (47ft2) 1.1.3.1 NON STATE-REGULATED BUILDINGS, STRUCTURES AND APPLICATIONS. <br /> TENTATIVE IMPROVEMENTS: CEILING HEIGHT=8'-0" EXCEPT AS MODIFIED BY LOCAL ORDINANCE PURSUANT TO SECTION 1.1.8, A <br /> THE FOLLOWING STANDARDS IN THE CALIFORNIA CODE OF REGULATIONS, v J <br /> TITLE 24,PARTS 2,2.5, 3,4, 5, 6,9, 10 AND 11 SHALL APPLY TO ALL <br /> PROPOSED CONVENIENCE STORE "PRIME MARKET" (2,650W)AT <br /> OCCUPANCIES AND APPLICATIONS NOT REGULATED BY A STATE AGENCY. Q p y d w <br /> 234 WEST YOSEMITE AVENUE,CITY OF MANTECA,CA 95336. INSIDE THE 0f 4'-0" <br /> OX2 X2 OX2 OX20 <br /> 0 <br /> MAIN FLOOR IS (1 935ft2)WITH(2)TWO OFFICES ONE AT(176ftz)AND ONE AT OX2 <br /> (150ft2). THERE IS A BACK STORAGE ROOM AT(218ftz)AND A UNISEX o T-1" DIVISION II SCOPE AND ADMINISTRATION v .0 V) o <br /> RESTROOM AT(47ftz). THERE ARE(6) SIX PARKING SPOTS FOR THIS BUILDING ~� W3 1 °Y <br /> C.17 �, �" <br /> AT THE BACK OF THE PROPERTY ON EAST OTIS STREET. THERE ARE (9)NINE o EXISTING EXISTING - r 1 <br /> PARKING SPOTS AND A ADA PARKING SPOT ON THE WEST SIDE OF THIS o OFFICE#1 (176ftz) OFFICE#2(150ftz) o p SECTION 106-CONSTRUCTION DOCUMENTS <br /> BUILDING CALLED "CROSSROADS PARKING". THIS MERCANTILE STORE HAS <br /> A 28'-6"FRONTAGE ON WEST YOSEMITE AVENUE WITH(2)TWO PARKING CEILING HEIGHT=8'-0" CEILING HEIGHT= 15'-0" 3'DOOR <br /> SPOTS IN FRONT. 106.1 GENERAL.� Z <br /> SUBMITTAL DOCUMENTS CONSISTING OF CONSTRUCTION DOCUMENTS, , <br /> THIS SITE HAS AND EXISTING FRONTAGE ROAD(W.YOSEMITE AVE)ON THE 5,-51f SPECIAL INSPECTION AND STRUCTURAL OBSERVATION PROGRAMS, <br /> NORTH SIDE OF THE PROPERTY. INVESTIGATION AND EVALUATION REPORTS,AND OTHER DATA SHALL BE <br /> EX. 4"X4"POST T-6" •T• 6'-0" T-0" T-6" _ SUBMITTED IN TWO OR MORE SETS WITH EACH APPLICATION FOR A PERMIT. a' <br /> THE EXISTING CITY OF MANTECA STORM ACCESS IS SOUTH AND WEST OF 15'-0" TALL I DOUBLE DOOR N O a <br /> EXCEPTION: THE CODE OFFICIAL IS AUTHORIZED TO WAIVE THE SUBMISSION U <br /> THE PROPERTY PROVIDED BY 12" STORM DRAIN GRATES ON(E. OTIS ST.) - _ _ � �, �� _ oo r" <br /> �C 9'UP ON � OF CONSTRUCTION DOCUMENTS AND OTHER DATA NOT REQUIRED TO BE °v <br /> v, EXISTING BUILDING(1,935ftz) 3 DOOR `N <br /> THE EXISTING CITY OF MANTECA SEWER ACCESS IS SOUTH OF THIS �' c7 W POST -� x PREPARED BY A REGISTERED DESIGN PROFESSIONAL IF IT IS FOUND THAT THE o <br /> �., PROPOSED CONVENIENCE STORE FLOOR XC7 NATURE OF THE WORK APPLIED FOR IS SUCH THAT REVIEWING OF {aj <br /> BUILDING BEHIND(E. OTIS ST.) CEILING HEIGHT= 15'-0" _ o m =i O <br /> �C o -' CONSTRUCTION DOCUMENTS IS NOT NECESSARY TO OBTAIN COMPLIANCE00 <br /> THE EXISTING CAL WATER IS BEHIND THIS EXISTING BUILDING IN THE co `n N W W WITH THIS CODE. <br /> PLANTER BEFORE PARKING. N O o e N <br /> - t w N 106.2 CONSTRUCTION DOCUMENTS. <br /> THE EXISTING PG&E GAS UTILITY IS ON THE EAST SIDE OF THIS EXISTING o :�'\ II U CONSTRUCTION DOCUMENTS SHALL BE IN ACCORDANCE WITH SECTIONS a3 a, <br /> BUILDING BEHIND A LOCKED WROUGHT IRON GATE. 8'-0" 106.2.1 THROUGH 106.2.5. <br /> YOU MUST CALL CITY OF MANTECA,CAL WATER,AND PG&E FOR X2 106.2.1 CONSTRUCTION DOCUMENTS. <br /> PROPOSED TIE-INS/STUB-UPS TO THESE EXISTING UTILITIES. o o CONSTRUCTION DOCUMENTS SHALL BE DIMENSIONED AND DRAWN UPON <br /> SUITABLE MATERIAL. ELECTRONIC MEDIA DOCUMENTS ARE PERMITTED TO <br /> 50 BE SUBMITTED WHERE APPROVED BY THE CODE OFFICIAL. CONSTRUCTION <br /> UTILITY NOTES: X4 X2 X2 DOCUMENTS SHALL BE OF SUFFICIENT CLARITY TO INDICATE THE LOCATION, f—LI <br /> THE UNDERGROUND UTILITIES SHOWN HAVE BEEN LOCATED FROM FIELD SURVEY (� (� X2 NATURE AND EXTENT OF THE WORK PROPOSED AND SHOW IN DETAIL THAT IT T 1 O <br /> INFORMATION AND EXISTING DRAWINGS.THE SURVEYOR MAKES NO GUARANTEE THAT I—I T( T( WILL CONFORM TO THE PROVISIONS OF THIS CODE AND RELEVANT LAWS, w <br /> THE UNDERGROUND UTILITIES SHOWN COMPRISE ALL SUCH UTILITIES IN THE AREA,EITHER ORDINANCES,RULES AND REGULATIONS,AS DETERMINED BY THE CODE <br /> IN SERVICE OR ABANDONED.THE SURVEYOR FURTHER DOES NOT GUARANTEE THAT THE OFFICIAL. THE WORK AREAS SHALL BE SHOWN. <br /> UNDERGROUND UTILITIES SHOWN ARE IN THE EXACT LOCATION INDICATED ALTHOUGH HE w \p <br /> DOES CERTIFY THAT THEY ARE LOCATED AS ACCURATELY AS POSSIBLE FROM Q ✓� N <br /> INFORMATION AVAILABLE.THE SURVEYOR HAS NOT PHYSICALLY LOCATED THE 81'-6" SECTION 109-INSPECTIONS Q M <br /> UNDERGROUND UTILITIES. P4 <br /> EXISTING FLOOR PLAN 109.3.6 FIRE AND SMOKE-RESISTANT PENETRATIONS. <br /> SCALE: 3/16"- F-0" PROTECTION OF JOINTS AND PENETRATIONS IN FIRE-RESISTANCE-RATED <br /> BUILDING CODE ANALYSIS. - z U <br /> DESCRIPTION OF USE: CONVENIENCE STORE ASSEMBLIES, SMOKE BARRIERS AND SMOKE PARTITIONS SHALL NOT BE Z W <br /> CONCEALED FROM VIEW UNTIL INSPECTED AND APPROVED. W w M <br /> OCCUPANCY GROUP: GROUP M <br /> TYPE OF CONSTRUCTION: WOOD&CMU <br /> FIRE SPRINKLERS: NO <br /> STORIES: 1 O Z <br /> BUILDING HEIGHT: 151-011W W <br /> ALLOWABLE FLOOR AREA: 2,650ftz M <br /> FLOOR AREA: 2,650ftz �j N <br /> OCCUPANCY LOAD(CBC): 40 MAX. <br /> OCCUPANCY LOAD(CPC): 40 MAX. ^� <br /> Q <br /> LEGEND <br /> EXIT ILLUMINATED EXIT SIGN <br /> DUPLEX AC OUTLET 120V <br /> X2 �I <br /> DUAL-DUPLEX AC OUTLET 120V <br /> OCCUPANCY SENSOR SWITCH <br /> B MOTION SENSOR SWITCH <br /> TELEPHONE JACK a <br /> C) <br /> 6X1 LUMINARE LIGHTS ~� O <br /> W OZt <br /> N <br /> UNAUTHORIZED CHANGES&USES: <br /> The design firm preparing these plans will not be responsible for,or liable for, I� <br /> unauthorized changes to or uses of these plans.All changes to these plans MUST be in <br /> THE ISSUANCE OF A PERMIT OR APPROVAL OF PLANS OR SPECIFICATIONS writing and must be approved by the preparer of these plans. <br /> SHALL NOT BE DEEMED OR CONSTRUED TO BE A PERMIT FOR AN <br /> APPROVAL OF ANY VIOLATION OF ANY OF THE PROVISIONS OF THE <br /> CALIFORNIA STATE BUILDING CODES OR LOCAL ORDINANCES. DESIGN BY: G.MENDOZ <br /> Construction contractor agrees that in accordance with generally acepted construction <br /> practices,construction contractor will be required to assume sole and complete DRAWN BY: G.MENDOZ <br /> Responsibility for job site conditions during the course of constructionof the project, SCALE: SCALE: 3/16"= F-0" <br /> NOTE: ELETRONIC VERSIONS OF THE LINEWORK ON THIS PLAN MAY NOT including safety of all persons and property;that this requirement shall be made to apply <br /> BE CONSISTANT WITH OTHER DIMENSIONS,NOTES,DETAILS,OR continuously and not to be limited to normal working hours, and construction contractor DATE: 11/26/2020 <br /> DESCRIPTIONS WHICH CONTROL THE INTENT DESIGN.ELECTRONIC further agrees to defend,imdemnify and hold design professional harmless from any <br /> VERSIONS OF THE PLAN ARE NOT TO BE USED TO ESTABLISH THE and all liability,real or alleged,in connection with the performance of work on this <br /> LOCATION OF PROPERTY OR IMPROVEMENTS IN THE FIELD. project, except liability arising from the sole negligence of the design professional. <br /> A2 . 0 <br />