REVISIONS
<br /> TENTATIVE IMPROVEMENT PLANS FOR: REV DATE DESCRIPTION
<br /> PRIME MARKET 234 WEST YOSEMITE AVE MANTECA CA 95336
<br /> 4
<br /> W . J(11 78U2 �� +
<br /> EXISTING CONDITIONS: 921-6" 2019 CALIFORNIA EXISTING BUILDING �I Expires
<br /> W
<br /> EXISTING VACANT BUILDING(2,650ft2)WITHIN A(7,800W)BUILDING LOCATEDCODE a'
<br /> 82'-6"
<br /> AT 234 WEST YOSEMITE AVENUE,CITY OF MANTECA,CA 95336, (LAT: 37.79720, . "
<br /> LONG: -121.21859)ELEV: 37',WITHIN PARCEL APN: 219-400-01,REVISED MAP OF 55'-6" 13'-6" 11'-6" 9'-6" CHAPTER 1: SCOPE AND ADMINISTRATION '
<br /> NORTH MANTECA,BOOK 219,PAGE 40,LOT#1,BLDG#7 DIVISION I-CALIFORNIA ADMINISTRATION
<br /> ZONING: CENTRAL BUSINESS OVERLAY ZONE 1 (CBD). EXISTING
<br /> 6'-0" 50'-0" RESTROOM (47ft2) 1.1.3.1 NON STATE-REGULATED BUILDINGS, STRUCTURES AND APPLICATIONS.
<br /> TENTATIVE IMPROVEMENTS: CEILING HEIGHT=8'-0" EXCEPT AS MODIFIED BY LOCAL ORDINANCE PURSUANT TO SECTION 1.1.8, A
<br /> THE FOLLOWING STANDARDS IN THE CALIFORNIA CODE OF REGULATIONS, v J
<br /> TITLE 24,PARTS 2,2.5, 3,4, 5, 6,9, 10 AND 11 SHALL APPLY TO ALL
<br /> PROPOSED CONVENIENCE STORE "PRIME MARKET" (2,650W)AT
<br /> OCCUPANCIES AND APPLICATIONS NOT REGULATED BY A STATE AGENCY. Q p y d w
<br /> 234 WEST YOSEMITE AVENUE,CITY OF MANTECA,CA 95336. INSIDE THE 0f 4'-0"
<br /> OX2 X2 OX2 OX20
<br /> 0
<br /> MAIN FLOOR IS (1 935ft2)WITH(2)TWO OFFICES ONE AT(176ftz)AND ONE AT OX2
<br /> (150ft2). THERE IS A BACK STORAGE ROOM AT(218ftz)AND A UNISEX o T-1" DIVISION II SCOPE AND ADMINISTRATION v .0 V) o
<br /> RESTROOM AT(47ftz). THERE ARE(6) SIX PARKING SPOTS FOR THIS BUILDING ~� W3 1 °Y
<br /> C.17 �, �"
<br /> AT THE BACK OF THE PROPERTY ON EAST OTIS STREET. THERE ARE (9)NINE o EXISTING EXISTING - r 1
<br /> PARKING SPOTS AND A ADA PARKING SPOT ON THE WEST SIDE OF THIS o OFFICE#1 (176ftz) OFFICE#2(150ftz) o p SECTION 106-CONSTRUCTION DOCUMENTS
<br /> BUILDING CALLED "CROSSROADS PARKING". THIS MERCANTILE STORE HAS
<br /> A 28'-6"FRONTAGE ON WEST YOSEMITE AVENUE WITH(2)TWO PARKING CEILING HEIGHT=8'-0" CEILING HEIGHT= 15'-0" 3'DOOR
<br /> SPOTS IN FRONT. 106.1 GENERAL.� Z
<br /> SUBMITTAL DOCUMENTS CONSISTING OF CONSTRUCTION DOCUMENTS, ,
<br /> THIS SITE HAS AND EXISTING FRONTAGE ROAD(W.YOSEMITE AVE)ON THE 5,-51f SPECIAL INSPECTION AND STRUCTURAL OBSERVATION PROGRAMS,
<br /> NORTH SIDE OF THE PROPERTY. INVESTIGATION AND EVALUATION REPORTS,AND OTHER DATA SHALL BE
<br /> EX. 4"X4"POST T-6" •T• 6'-0" T-0" T-6" _ SUBMITTED IN TWO OR MORE SETS WITH EACH APPLICATION FOR A PERMIT. a'
<br /> THE EXISTING CITY OF MANTECA STORM ACCESS IS SOUTH AND WEST OF 15'-0" TALL I DOUBLE DOOR N O a
<br /> EXCEPTION: THE CODE OFFICIAL IS AUTHORIZED TO WAIVE THE SUBMISSION U
<br /> THE PROPERTY PROVIDED BY 12" STORM DRAIN GRATES ON(E. OTIS ST.) - _ _ � �, �� _ oo r"
<br /> �C 9'UP ON � OF CONSTRUCTION DOCUMENTS AND OTHER DATA NOT REQUIRED TO BE °v
<br /> v, EXISTING BUILDING(1,935ftz) 3 DOOR `N
<br /> THE EXISTING CITY OF MANTECA SEWER ACCESS IS SOUTH OF THIS �' c7 W POST -� x PREPARED BY A REGISTERED DESIGN PROFESSIONAL IF IT IS FOUND THAT THE o
<br /> �., PROPOSED CONVENIENCE STORE FLOOR XC7 NATURE OF THE WORK APPLIED FOR IS SUCH THAT REVIEWING OF {aj
<br /> BUILDING BEHIND(E. OTIS ST.) CEILING HEIGHT= 15'-0" _ o m =i O
<br /> �C o -' CONSTRUCTION DOCUMENTS IS NOT NECESSARY TO OBTAIN COMPLIANCE00
<br /> THE EXISTING CAL WATER IS BEHIND THIS EXISTING BUILDING IN THE co `n N W W WITH THIS CODE.
<br /> PLANTER BEFORE PARKING. N O o e N
<br /> - t w N 106.2 CONSTRUCTION DOCUMENTS.
<br /> THE EXISTING PG&E GAS UTILITY IS ON THE EAST SIDE OF THIS EXISTING o :�'\ II U CONSTRUCTION DOCUMENTS SHALL BE IN ACCORDANCE WITH SECTIONS a3 a,
<br /> BUILDING BEHIND A LOCKED WROUGHT IRON GATE. 8'-0" 106.2.1 THROUGH 106.2.5.
<br /> YOU MUST CALL CITY OF MANTECA,CAL WATER,AND PG&E FOR X2 106.2.1 CONSTRUCTION DOCUMENTS.
<br /> PROPOSED TIE-INS/STUB-UPS TO THESE EXISTING UTILITIES. o o CONSTRUCTION DOCUMENTS SHALL BE DIMENSIONED AND DRAWN UPON
<br /> SUITABLE MATERIAL. ELECTRONIC MEDIA DOCUMENTS ARE PERMITTED TO
<br /> 50 BE SUBMITTED WHERE APPROVED BY THE CODE OFFICIAL. CONSTRUCTION
<br /> UTILITY NOTES: X4 X2 X2 DOCUMENTS SHALL BE OF SUFFICIENT CLARITY TO INDICATE THE LOCATION, f—LI
<br /> THE UNDERGROUND UTILITIES SHOWN HAVE BEEN LOCATED FROM FIELD SURVEY (� (� X2 NATURE AND EXTENT OF THE WORK PROPOSED AND SHOW IN DETAIL THAT IT T 1 O
<br /> INFORMATION AND EXISTING DRAWINGS.THE SURVEYOR MAKES NO GUARANTEE THAT I—I T( T( WILL CONFORM TO THE PROVISIONS OF THIS CODE AND RELEVANT LAWS, w
<br /> THE UNDERGROUND UTILITIES SHOWN COMPRISE ALL SUCH UTILITIES IN THE AREA,EITHER ORDINANCES,RULES AND REGULATIONS,AS DETERMINED BY THE CODE
<br /> IN SERVICE OR ABANDONED.THE SURVEYOR FURTHER DOES NOT GUARANTEE THAT THE OFFICIAL. THE WORK AREAS SHALL BE SHOWN.
<br /> UNDERGROUND UTILITIES SHOWN ARE IN THE EXACT LOCATION INDICATED ALTHOUGH HE w \p
<br /> DOES CERTIFY THAT THEY ARE LOCATED AS ACCURATELY AS POSSIBLE FROM Q ✓� N
<br /> INFORMATION AVAILABLE.THE SURVEYOR HAS NOT PHYSICALLY LOCATED THE 81'-6" SECTION 109-INSPECTIONS Q M
<br /> UNDERGROUND UTILITIES. P4
<br /> EXISTING FLOOR PLAN 109.3.6 FIRE AND SMOKE-RESISTANT PENETRATIONS.
<br /> SCALE: 3/16"- F-0" PROTECTION OF JOINTS AND PENETRATIONS IN FIRE-RESISTANCE-RATED
<br /> BUILDING CODE ANALYSIS. - z U
<br /> DESCRIPTION OF USE: CONVENIENCE STORE ASSEMBLIES, SMOKE BARRIERS AND SMOKE PARTITIONS SHALL NOT BE Z W
<br /> CONCEALED FROM VIEW UNTIL INSPECTED AND APPROVED. W w M
<br /> OCCUPANCY GROUP: GROUP M
<br /> TYPE OF CONSTRUCTION: WOOD&CMU
<br /> FIRE SPRINKLERS: NO
<br /> STORIES: 1 O Z
<br /> BUILDING HEIGHT: 151-011W W
<br /> ALLOWABLE FLOOR AREA: 2,650ftz M
<br /> FLOOR AREA: 2,650ftz �j N
<br /> OCCUPANCY LOAD(CBC): 40 MAX.
<br /> OCCUPANCY LOAD(CPC): 40 MAX. ^�
<br /> Q
<br /> LEGEND
<br /> EXIT ILLUMINATED EXIT SIGN
<br /> DUPLEX AC OUTLET 120V
<br /> X2 �I
<br /> DUAL-DUPLEX AC OUTLET 120V
<br /> OCCUPANCY SENSOR SWITCH
<br /> B MOTION SENSOR SWITCH
<br /> TELEPHONE JACK a
<br /> C)
<br /> 6X1 LUMINARE LIGHTS ~� O
<br /> W OZt
<br /> N
<br /> UNAUTHORIZED CHANGES&USES:
<br /> The design firm preparing these plans will not be responsible for,or liable for, I�
<br /> unauthorized changes to or uses of these plans.All changes to these plans MUST be in
<br /> THE ISSUANCE OF A PERMIT OR APPROVAL OF PLANS OR SPECIFICATIONS writing and must be approved by the preparer of these plans.
<br /> SHALL NOT BE DEEMED OR CONSTRUED TO BE A PERMIT FOR AN
<br /> APPROVAL OF ANY VIOLATION OF ANY OF THE PROVISIONS OF THE
<br /> CALIFORNIA STATE BUILDING CODES OR LOCAL ORDINANCES. DESIGN BY: G.MENDOZ
<br /> Construction contractor agrees that in accordance with generally acepted construction
<br /> practices,construction contractor will be required to assume sole and complete DRAWN BY: G.MENDOZ
<br /> Responsibility for job site conditions during the course of constructionof the project, SCALE: SCALE: 3/16"= F-0"
<br /> NOTE: ELETRONIC VERSIONS OF THE LINEWORK ON THIS PLAN MAY NOT including safety of all persons and property;that this requirement shall be made to apply
<br /> BE CONSISTANT WITH OTHER DIMENSIONS,NOTES,DETAILS,OR continuously and not to be limited to normal working hours, and construction contractor DATE: 11/26/2020
<br /> DESCRIPTIONS WHICH CONTROL THE INTENT DESIGN.ELECTRONIC further agrees to defend,imdemnify and hold design professional harmless from any
<br /> VERSIONS OF THE PLAN ARE NOT TO BE USED TO ESTABLISH THE and all liability,real or alleged,in connection with the performance of work on this
<br /> LOCATION OF PROPERTY OR IMPROVEMENTS IN THE FIELD. project, except liability arising from the sole negligence of the design professional.
<br /> A2 . 0