My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
WORK PLANS
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
P
>
PACIFIC
>
5202
>
1600 - Food Program
>
PR0547134
>
WORK PLANS
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/16/2021 12:05:33 PM
Creation date
10/12/2021 3:52:10 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
1600 - Food Program
File Section
WORK PLANS
RECORD_ID
PR0547134
PE
1625
FACILITY_ID
FA0026740
FACILITY_NAME
IN-N-OUT BURGERS
STREET_NUMBER
5202
STREET_NAME
PACIFIC
STREET_TYPE
AVE
City
STOCKTON
Zip
95207
CURRENT_STATUS
01
SITE_LOCATION
5202 PACIFIC AVE
P_LOCATION
01
QC Status
Approved
Scanner
SJGOV\jcastaneda
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
89
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
TOCELL MOUNTED <br /> TOIRRIGATIONPEDESTAL 24 <br /> O8 SITE PLAN NOTES NOTES BY SYMBOL `O <br /> n <br /> 23 <br /> PC PLANS.A. REFER TO SHEET E2.1 FOR GENERAL NOTES AND E10.0 FOR SPECIFICATIONS. APPLICABLE TO ALL <br /> �L7= IA <br /> CONDUIT BELOW GRADE O PROVIDE 2 - 4" CONDUITS ROUTED FROM THE UTILITY PAD MOUNTED TRANSFORMER TO THE O PROVIDE 20A, 1 P, 120V RATED WEATHERPROOF DISCONNECT FOR DIRECTIONAL SIGNS, MONUMENT <br /> Eli I <br /> POWER COMPANY SERVICE POINT. PROVIDE ALL TRENCHING, BACK FILL & CONCRETE ENCASEMENT SIGN, AND O.S MENU SIGN, V.L. REFER TO SIGNAGE PACKAGE FOR EXACT SIGN LOCATIONS. <br /> OEB. ALL SERVICE REQUIREMENTS (POWER AND TELEPHONE) TO RENDER SERVICE TO THE PROJECT SHALL BE AS REQUIRED BY POWER COMPANY. REFER TO THE CIVIL UTILITY PLAN AND THE UTILITY SERVICE Architecture / Development <br /> _ fl VERIFIED WITH THE SERVING UTILITY COMPANIES PRIOR TO BID. ALL COSTS LEVIED BY THE UTILITY PLAN FOR ALL ELECTRIC SERVICE REQUIREMENTS PRIOR TO THE BASE BID & ROUGH-IN. INSTALL 0 PROVIDE (3) - 1"C. CONDUITS TO MIS ROOM FROM MENUBOARD. <br /> O F-3 COMPANIES SHALL BE INCLUDED IN THE BASE BID. NO ADDITIONAL COMPENSATION WILL BE ALLOWEDPER ALL UTILITY REQUIREMENTS. 14901 Quorum Drive <br /> �5 <br /> AFTER BIDDING PERIOD. 2 # 12, 1 # 12 G. 3/4" CONDUIT. Suite 300 <br /> MILK MIK C. VERIFY SWITCHBOARD METERING AND CONSTRUCTION REQUIREMENTS WITH POWER O PROVIDE 4 SETS OF 4" CONDUITS ROUTED FROM THE UTILITY PAD MOUNTED TRANSFORMER TO CT Dallas Texas 75254 <br /> CRATE CRATE CRATE 20 WP_GFCL - CABINET - METER. PROVIDE ALL TRENCHING BACK FILL & CONCRETE ENCASEMENT AS REQUIRED O PROVIDE A DEDICATED 1" CONDUIT FROM THE INDICATED LOCATION TO THE INTERIOR JUNCTION BOX Ph: (972)239-8884 <br /> WP GFCI +24„ AFF COMPANY. BY POWER COMPANY. REFER TO THE CIVIL UTILITY PLAN AND THE UTILITY SERVICE PLAN FOR ALL FOR SECURITY CAMERAS. REFER TO SHEET E7.0 FOR FURTHER INFORMATION. Fax: (972)239-5054 <br /> SPARE ELECTRIC SERVICE REQUIREMENTS PRIOR TO THE BASE BID & ROUGH-IN. NVE TO PROVIDE <br /> +24” AFF F-1 D. INSTALL POWER AND TELEPHONE SERVICE CONDUITS BELOW GRADE ENCASED IN SERVICE FEEDERS. O PROVIDE 3/4" CONDUIT FOR CONNECTION BETWEEN SPEAKER AND MENU BOARD. ISSUE RECORD <br /> COMPACTOR BIN CONCRETE (IF REQUIRED), PER UTILITY COMPANY REQUIREMENTS. <br /> O PROVIDE 1 - 4" CONDUIT (TELEPHONE) & 1-2" CONDUIT (FOR CATV), EACH ROUTED FROM THE O 1 1/2" CONDUIT INTO BUILDING FOR FIRE ALARM MONITORING WIRING ACCESS. ROUTE CONDUIT IN URBAN DESIGN PROTOTYPE <br /> DATE DESCRIPTION <br /> E. REFER TO SHEET E9.0 FOR LIGHTING CONTROLS. SECURITY NIGHT LIGHT SHALL BE IN-N-OUT BURGER TELEPHONE SERVICE BACKBOARD TO TELEPHONE COMPANY SERVICE POINT AND TRENCH ALONG WITH FIRE PROTECTION SYSTEM WATER LINE. <br /> PANEL "F" WITH MCI F PROVIDED WITH SEPARATE OVERRIDE SWITCH. THE CATV SERVICE BACKBOARD TO THE CAN COMPANY SERVICE POINT. PROVIDE ALL TRENCHING, 7-10-2020 ISSUED FOR PERMIT <br /> SUITABLE FOR SERVICE BUN D1 BACK FILL & CONCRETE ENCASEMENT AS REQUIRED BY TELEPHONE COMPANY. REFER TO THE CIVIL �9 NOT USED. <br /> ENTRANCE DISCONNECT PER RACK F. REFER TO SHEET E11 .0 FOR EXTERIOR LIGHT PHOTOMETRICS AND LIGHTING UTILITY PLAN AND THE TELEPHONE UTILITY SERVICE PLAN FOR ALL REQUIREMENTS PRIOR TO BASE <br /> NEC. SECTION 225.36. PANEL SPECIFICATIONS. BID & ROUGH-IN. INSTALL PER ALL UTILITY REQUIREMENTS. 20 PROVIDE GFI DUPLEX RECEPTACLE FOR POWER CONNECTION TO HEAT TRACE DEVICE AT HOSE BIBS. <br /> IS PROVIDED SERVICE GROUND O O O O RECYCLING BIN O PROVIDE PARKING LOT LIGHTING FIXTURES TYPE AS INDICATED, TYPICAL. <br /> AT THE PANEL LOCATION. F � z G. COORDINATE LOCATION OF LIGHT POLE BASES WITH CIVIL, LANDSCAPING AND IRRIGATION. 2� PROVIDE A PERMANENT PLAQUE "PANEL F IS LOCATED INSIDE TRASH ENCLOSURE". <br /> REFER TO SINGLE LINE J °D (4 CU YDS.) H. BURIAL DEPTH OF CONDUITS UNDER PARKING LOT IS 24" BELOW GRADE. O 1 1/2" CONDUIT TO THE HOME PA SYSTEM O ALL EXTERIOR GFI/WP RECEPTACLES LOCATED ON POLE LIGHTS SHALL BE REQUIRED <br /> DIAGRAM SHEET E2.0 L —1Q Q D1 WEATHERPROOF COVER, WITH ATTACHMENT PLUG CAP INSERTED INTO RECEPTACLE ("IN-USE" TYPE) <br /> v O REFER TO ENLARGED TRASH ENCLOSURE PLAN E1.0/3. AS PER CEC 406.9(8). <br /> z `-" <br /> z O 2 # 10, 1 # 10 G. 3/4" CONDUIT. 02 # 8, 1 # 10 G. 3/4" CONDUIT. 3 12"x12" ELECTRICAL BOX WITH STAINLESS STEEL ACCESS PANEL FOR WIRELESS ACCESS POINT. <br /> O O — UTILITY 1 REPRESENTATIVES INSTALL A CONDUIT FROM THE MIS SERVER ROOM TO THE ENCLOSURE FOR CONNECTION. <br /> O IRRIGATION CONTROLLER, VERIFY EXACT LOCATION WITH IRRIGATION CONTRACTOR. 2L <br /> GENERAL NOTE: 00 _ 1'X4' RECESSED LIGHTING FIXTURE TYPE "D1" ON PLASTER CEILING, TYPICAL REFER TO INTERMATIC PHOTOCONTROL MODEL # EK4236S TO CONTROL TRASH ENCLOSURE LIGHTING POWERED REVISION RECORD <br /> EXCEPT ELECTRICAL PANEL, <br /> F-2/4/6 D1 TELEPHONE PROVIDER: CONTACT: GINO PINEDA TITLE: O ARCHITECTURAL DWG. FOR LOCATION. THROUGH CIRCUIT F-1, PANEL F IN TRASH ENCLOSURE. DUSK TO DAWN ON/OFF CONTROL. <br /> AT&T CONSULTANT <br /> ALL ELECTRICAL BOXES AND X—j COMPOSTABLE BIN TELEPHONE: 469.818.9565 25 CONTRACTOR TO PROVIDE A WP JUNCTION BOX AND 1 1/2" EMPTY CONDUITS WITH <br /> CONDUITS SHALL BE RECESSED (4 CU YDS.) 0 3 # 12, 1 # 12 GND, 3/4" CONDUIT. PULL STRING TO THE PANEL "F" LOCATED IN THE TRASH ENCLOSURE FOR FUTURE <br /> IN BLOCK WALL. ALL LIGHT FIXTURES ARE O EV CHARGING STATION. <br /> CONTROLLED BY A PHOTOCF LL ELECTRIC PROVIDER: CONTACT: CUSTOMER SERVICES TRASH COMPACTOR 7 FLA, 208V, 3�. CONNECT TO THE CIRCUIT BREAKER AS SHOWN IN <br /> 11 TELEPHONE: 877.743.7782 - DESIGNATED CIRCUIT HOMERUN. COMPLETE CONNECTION TO TRASH COMPACTOR CONTROL SWITCH. <br /> PACIFIC GAS AND ELECTRIC BUILDING SERVICES CIRCUIT SHALL BE FED FROM LOCKABLE CIRCUIT BREAKER DEVICE. L0 DUPLEX PUMP PACKAGED LIFT STATION 2HP-208V-3PH. COORDINATE WITH CIVIL <br /> VERTICAL I � SACRAMPO ENTO, �A 99730958990 TELEPHONE: 1.800.PGE.5000 - ENGINEER FOR EXACT CONTROL PANEL LOCATION PRIOR TO INSTALLATION. PROVIDE <br /> MAIN 2 PROVIDE A 24 W X 36 H X 6 DEEP TELEPHONE ENCLOSURE WITH A PLYWOOD BACKBOARD. A 30A-3P-25OV SAFETY SWITCH. RUN 3#10 + 1#10G. - 3/4"C AND CONNECT TO <br /> LTRASH PROVIDE A #6 AWG CU GND WIRE TO MSB AND A QUAD 120V RECEPTACLE AT TELCO BACKBOARD. PANEL CIRCUIT F-6/10/12, PANEL IS LOCATED IN TRASH ENCLOSURE. FINAL <br /> L —ij L COORDINATION WITH EQUIPMENT SUPPLIER AND PROVIDE EXACT POWER <br /> O CABLE PROVIDER: TELEPHONE: 888.489.3591 REQUIREMENTS PER EQUIPMENT'S NAME PLATE SHOWN PRIOR TO INSTALLATIONS. <br /> DIRECT TV Website: www.directv.com ADJUST THE CIRCUIT BREAKER AMP RATING IF REQUIRED. <br /> O O O <br /> I • <br /> ENLARGED - <br /> TRASHENCLOSURE PROFESSIONAL SEAL <br /> 03 SCALE: NOT TO SCALE O W ° F � QRpFESS/p <br /> O <br /> < 0 <br /> =O a I 17 Exp. 09/30/22 'V <br /> U O O LC-------- --ROH--- \ <br /> O F i Q I s (SIDPAKER & <br /> TYPICAL SITE POLE L o P ME U BOARD) <= o OF CAI \ 10/14/20 <br /> LIGHTING FIXTURE, I I O <br /> REFER TO DWG. E.11.0 B-28 a <br /> SITE LIGHTING FIXTURE O -- 4 <br /> SCHEDULE FOR LIGHTING ®� — — MoeO <br /> SPECIFICATIONS = Q O <br /> 0A1 16 ROH 6 0A1 OA1 W <br /> 16 2- <br /> tM <br /> o°°°°o o° <br /> 1 coNoulT 0 - ---------------------voH ---------------- engineering consultants <br /> wf7O 14901 Quorum Dr. #565 Dallas, TX 75254 <br /> o "PG E o&t O -40 rtmassociates.com 1 972.387.3500 <br /> 0 16 o P <br /> POLE � O o I , I� <br /> (DRIV THRU IGN) <br /> (SEE DWG. E11.0 <br /> FOR LIGHTING O PR PO ED PA MT 1 <br /> SPECIFICATIONS) B 7 a --- - -- -- PROTOTYPE VERSION <br /> Q /29 L <br /> 16U.2.61 <br /> (SECURITY LIGHTS) <br /> 4"T ° ° Z <br /> � <br /> �° Y 25 PROJECT NAME <br /> 3 wi <br /> HANDHOLE 6� ON)B-22o SEWER PUMPS' 26 <br /> ° CONTROL PANEL W <br /> SECURITY LIGHTS ; opo O�O� <br /> & COVER 2°'w ( )1 , I I 26 I N N O UT <br /> ATV BOARDS EV CHI GING 3/ooe NV: <br /> GROUND LUG O 12 ELEPHONE BOARD o STATI0 1 B U RG E R <br /> 10---------- I ° 20 70-1�O J o------------ (SECURITY LIGHTS) 7A <br /> THE METAL POLE MUST BE (SIG ) C-�BON)7 n m J B-17 (ON) -21/2 <br /> CONNECTED TO AN EQUIPMENT <br /> GROUNDING CONDUCTOR OFA o z z z 3110 ® 8_42 2-2 COND ITS o a z2 FI WP STO C KTO N <br /> BASE PLATE BY LIGHT 3 J ��� —E' <br /> POLE MANUFACTURER <br /> TYPE FOUND IN NEC 250.118 7 B-200 °�o O00 / J a <br /> PROVIDE NON-SHRINK GROUT I�� r ) A2 6 �-' a <br /> UNDER BASE PLATE � - ____- OO u�l 000 ® O 16 CALIFORNIA <br /> n �- ODMG3GCL3o <br /> �— <br /> �- --- 000 <br /> ANCHOR BOLTS SET N ❑® 5202 PACIFIC AVE <br /> CONCRETE POLE BASE WITH TEMPLATE FROM <br /> w <br /> MATCH SHOPPING wo STOCKTION, CA 95207 <br /> CENTER DESIGN POLE MANUFACTURER _ <br /> WHERE APPLICABLE. (SIZE AS REQUIRED __- -_ �1 (SECURITY IJ ) BON O <br /> ° <br /> BY LIGHT POLE O ° <br /> - � LIGHTS)-- 16 � 7 13 <br /> MANUFACTURER). `-4 g-20 O <br /> LEVEL POLE WITH -- --------� J W <br /> FINISHED GRADE ° LEVELING NUTS. <br /> 6 DO NOT <br /> GROUT UNDER BASE —Tsc ® TSC I B-25 11 ; 11 � ENTER SIGN) <br /> ° I <br /> a I OA11 '1 �~ <br /> M M <br /> ° W 6TU 16 <br /> o -ITF7 <br /> NmNmOUT3 dois <br /> - ° Q <br /> (MONUMENT SIGN) ------ - __ <br /> BVRGER® <br /> oil .9 <br /> = O\ GOD BLESS AMERICA <br /> CONDUIT AS SIZED 00 2"SLC8 <br /> ° No 2"SLC <br /> - ON PLANS O <br /> O <br /> PROJECT NUMBER <br /> d w <br /> / F_ 190955 <br /> Li <br /> c� <br /> O O O 00 AVENUE I SHEET TITLE <br /> 4= C ELECTRICAL SITE <br /> a °° g ° ------ ------ — -- �— -� — � — -- — � CPLAN NOTES AND <br /> f W <br /> DETAILS <br /> I (PUBLIC STREET) <br /> Underground Service Alert <br /> CD <br /> Z SITE LIGHTING STANDARD. P g�F = yoLa Call: Toll Free N N ELECTRICAL SITE PLAN SHEET NUMBER <br /> O SCALE: NOT TO SCALE O " <br /> 0 0 811 <br /> SCALE:1"=20'-O <br /> 5-1 Cj NOTE: 0 10 20 40 60 <br /> 0 o REFER TO STRUCTURAL PLANS FOR POLE BASE TWO WORKING DAYS <br /> Z Z STRUCTURAL DESIGN DETAIL & CALCULATION BEFORE YOU DIG El mO <br /> PROJECT NORTH TRUE NORTH GRAPHIC SCALE <br /> SCALE: 1"=20' <br />
The URL can be used to link to this page
Your browser does not support the video tag.