0 <br /> MAIN SWITCHBOARD "MSB" 1000 AMP 208Y/120V 3 0 4W 65,000 AIC MINIMUM RATING <br /> ABB Inc. CUSTOM SWITCHBOARD, CONTACT JANEALE MECHLING (949)-204-4410 <br /> Architecture / Development <br /> 14901 Quorum Drive <br /> I I 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 Suite 300 <br /> Dallas Texas 75254 <br /> 972)239-8884 <br /> M Fax:((972)239-5054 <br /> O 80A 80A 80A 80A 80A 80A 80A 80A 20A 20A 20A 20A 20A 200A 200A 200A 200A 30A 30A 100A ISSUE RECORD <br /> 3 POLE 3 POLE 3 POLE 3 POLE 3 POLE 3 POLE 3 POLE 3 POLE 1 POLE 1 POLE 1 POLE 1 POLE 1 POLE 3 POLE 3 POLE 3 POLE 3 POLE 3 POLE 3 POLE 2 POLE DATE DESCRIPTION <br /> O O O O O O O O O O O O URBAN DESIGN PROTOTYPE <br /> O <br /> 4 4 4 4 4 4 4 4 4 4 4 4 4 <br /> 7-10-2020 ISSUED FOR PERMIT <br /> 1000A MCB <br /> 3 POLE <br /> 30.3 <br /> C1 C2 C3 C4 C5 C6 C7 C8 C9 C10 C11 C12 C13 30.4 15' <br /> 100A-2P+S/N, <br /> 250V <br /> 200.4 200.4 200.4 200.4 NON-FUSIBLE <br /> 80.3 80.3 80.3 80.3 80.3 80.3 80.3 80.3 20.1 20.1 20.1 20.1 20.1 NSS UPS DISC. SWITCH <br /> 66' 65' 64' 63' 62' 52' 42' 44' 66' 65' 64' 63' 62' 53' S5' 65' <br /> O O REVISION RECORD <br /> __Q]) __Q:3 --Q:3 0.9% VD --Q:3 --Q:3 0.5% VD --Q:3 1.2% VD __Q:3 __Q:3 __Q:3 1.1% VD 0.6% VD 0.4% VD ­C3KDII65> Q 10-14-2020 <br /> CITY COMMENTS <br /> 0.7% VD 00.3 I <br /> - - PNL A <br /> - - - � F- - - - .7 F- _1 - - - � IT RM. 30' <br /> FUTURE FUTURE FUTURE FUTURE FUTURE <br /> FRYER FRYER FRYER FRYER FRYER GRIDDLE GRIDDLE GRIDDLE PNL B PNL C PNL HVAC <br /> I I I I I I I I I I GAS FRYER GAS FRYER GAS FRYER GAS FRYER GAS FRYER <br /> E-41A E-41A E-41A E-41A E-41A E-09 E-09 E-09 <br /> E-41 E-41 E-41 E-41 E-41 <br /> 200 _ (1) (2) (3) (4) (5) (1) (2) (3) (1) (2) (3) (4) (5) 100.4 PNL D <br /> SERVICE 20.980 KVA 20.980 KVA 20.980 KVA 20.980 KVA 20.980 KVA 16.248 KVA 16.248 KVA 16.248 KVA 0.720 KVA 0.720 KVA 0.720 KVA 0.720 KVA 0.720 KVA 180' <br /> 1.8% VD GROUNDING O O O EXHAUST FAN CONTROL PANEL 1 2 <br /> 0.2% VD - - <br /> 1000A ARC FLASH NOTE GRIDDLE GRIDDLE GRIDDLE PROVIDE PANEL'S LABEL: <br /> SWITCHBOARDS, PANELBOARDS, MOTOR CONTROL PANELS AND METER SOCKET E-08 E-08 E-08 PANEL "F" PNL F <br /> ENCLOSURES WHICH ARE LIKELY TO REQUIRE EXAMINATION, ADJUSTMENT, SERVICING, OR (1) (2) (3) FED FROM PANEL "A" <br /> UTILITY PAD MAINTENANCE WHILE ENERGIZED, SHALL BE FIELD MARKED TO WARN QUALIFIED PERSONS <br /> OF POTENTIAL ELECTRIC ARC FLASH HAZARDS PER NEC 110.16. A WARNING LABEL #4 GROUND PER NEC EF-3 EF-4 EF-5 EF-6 <br /> MOUNT XFMR SHALL BE SUFFICIENT. - 250.32(A) SERVICE GROUND. <br /> PROVIDE ISOLATED NEUTRAL (1 HP) (1 HP) (1 HP) (1 HP) PROFESSIONAL SEAL <br /> i ELECTRICAL SINGLE LINE DIAGRAM (NO JUMPER GROUND-NEUTRAL) - - QRpFESS <br /> 2 4"C O I SCALE: NOT TO SCALE (1 20.4 AMPS � 208V(3 X 3� 1728 VA) = 7344 VA �� P�L V, ���1 <br /> "'17o."E 13453" m <br /> MAIN DISTRIBUTION PANEL GROUNDING (PANEL MSB ) <br /> * Exp. 09/30/22 � <br /> NEUTRAL BUSPOWER FEEDER SCHEDULE `P� ��FCTR\GPS ,Q <br /> TYP. CKT. 65 K AMPERE qTF OF CAL�FO�� <br /> A B C #3/0 AWG (CU)RATING, TYPICAL BONDING JUMPER SINGLE LINE DIAGRAM NOTES <br /> FEEDER N0. OF CONDUCTOR NUMBER AND SIZE OF 10/15/20 <br /> 1, THE MAIN SWITCHBOARD "MSB" SHALL BE BRACED FOR 65,000 AMPS OF AVAILABLE FAULT CURRENT OR <br /> TAG CONDUIT SIZE CONDUCTORS SIZE GROUNDING CONDUCTOR <br /> GROUND BUS THE ACTUAL AVAILABLE FAULT CURRENT AS DETERMINED BY THE ELECTRIC UTILITY COMPANY, WHICHEVER 20.1 3 4" 2 12 1 12 <br /> CUSTOMER LOAD A B ® A B B IS GREATER. O / # # <br /> 2. ALL OF THE MAIN SWITCHBOARD CIRCUIT BREAKERS SHALL BE FULLY RATED FOR 65,000 AMPS OF 30.3 3/4" 3 #10 1 #10 <br /> AVAILABLE FAULT CURRENT AS SHOWN ON THIS SHEET. <br /> #4 AWG (CU) 30.4 3/4" 4 #10 1 #10 <br /> #4 AWG (CU) TO TELECOM 3. ALL OF THE PANELBOARDS AND PANELBOARD BRANCH CIRCUIT BREAKERS SHALL BE FULLY RATED FOR <br /> #3/0 AWG (CU) GROUND BAR 65,000 AMPS OF AVAILABLE FAULT CURRENT. 40.4 1" 4 #8 1 #10 <br /> TYPICAL engineering consultants <br /> rtm <br /> -ki, <br /> �VJ <br /> 4. ALL EQUIPMENT AND DEVICES SHALL BE RATED TO MATCH OR EXCEED ALL AVAILABLE UTILITY COMPANY 80.3 1-1/4" 3 #3 1 #8 14901 Quorum Dr. #565 Dallas, TX 75254 <br /> L N CONTACTOR I CADWELD CAPACITY. <br /> CADWELD rtmassociates.com 1 972.387.3500 <br /> TB 20' MIN. OF 1/2" REBAR #2/0 AWG (CU) 5. ALL FUSES SHALL BE CURRENT LIMITING TYPE EXCEPT WHERE NOTED. 90.3 1 1/4" 3 #2 1 #8 <br /> IN BUILDING FOOTING BUILDING <br /> L I UFER GROUND CADWELD #6 AWG (CU) STRUCTURAL EQUIPMENT 6. ALL CONDUCTORS SHALL BE COPPER, REFER TO SPECIFICATIONS SHEET E10.0 FOR ADDITIONAL g0.4 1 1/4" 4 #2 1 #8 <br /> ( ) STEEL ENCLOSURE REQUIREMENTS. O <br /> N BONDING JUMPER PROTOTYPE VERSION <br /> (3)3/4" x 10' I #3/0 AWG (CU) 7. ALL ELECTRICAL EQUIPMENT SHALL BE GROUNDED IN ACCORDANCE WITH NATIONAL ELECTRICAL CODE 100.2 1 1/4" 2 #1 1 #6 PROTOTYPE <br /> - I GROUND RODS GROUNDING ELECTRODE CONDUCTOR TO ARTICLE 250, AND ALL INSTALLATIONS SHALL CONFORM TO ALL NATIONAL ELECTRICAL CODE AND ALL <br /> - J LOCAL BUILDING CODES AN ORDINANCES <br /> MIN. 6' APART I I I METAL WATER PIPING IN DIRECT CONTACT . 00.3 I 1 1/2" 3 #1 2 #6, #6 IG <br /> PROJECT NAME <br /> DETAIL FIGURE 1 TYPICAL FOR CKTS. 1-13 WITH EARTH FOR MINIMUM 10'. CONNECTION 8. ALL ELECTRICAL PANELBOARDS SHALL BE PROVIDED WITH APPROVED LOCKING DEVICES. <br /> MADE WITHIN 5FT OF BUILDING ENTRY. 100.4 1 1/2" 4 #1 1 #6 <br /> g. ALL FEEDER LENGTHS SHOWN ON THE SINGLE LINE DIAGRAM ARE FOR CALCULATION PURPOSES ONLY. <br /> GAS METER I O�� <br /> CONTACTOR WIRING DETAIL THE ELECTRICAL CONTRACTOR SHALL VERIFY ALL FEEDER LENGTHS PRIOR TO BID. 125.3 1 1/2" 3 #1/0 1 #6 <br /> 03 <br /> 10• THE ELECTRICAL CONTRACTOR SHALL PROVIDE THE MAIN SWITCHBOARD AND ALL PANELBOARDS AND 200.4 2 1/2" 4 #3/0 1 #6 BURGER <br /> SCALE: NOT TO SCALE METER,VALVE OR O CIRCUIT BREAKERS AS MANUFACTURED BY GENERAL ELECTRIC COMPANY. ALL ELECTRICAL EQUIPMENT <br /> UNION PROVIDED BY THE ELECTRICAL CONTRACTOR SHALL BEAR THE UNDERWRITERS LABORATORY (UL) LABEL 250.4 2 1/2" 4 #250 1 #4 <br /> FOR THE SPECIFIC USES INSTALLED. ALL MATERIALS AND EQUIPMENT SHALL BE NEW. <br /> SECURED TO WALL #2/0 AWG (CU) <br /> BONDED GROUND ON 1000A 4 © 4" 4 SETS OF 4 #250 STO C IffO N <br /> MO NUT HARDUL LISTED GROUND CLAMPS CUSTOMER SIDE OF GAS CALIFORNIA <br /> MOUNTING NUT METER PIPE TO THE GAS <br /> EQUIPMENT SIZE CIRCUIT. <br /> LOCK WAS (NOT INTENDED TO BE 5202 PACIFIC AVE <br /> � GROUNDING ELECTRODE) <br /> 5/8" HARDWARE ti LOCK WASHER <br /> MOUNTING NUT EQUAL MAIN GROUNDING DETAIL FAULT CURRENT CALCULATION (L-L POINT-TO-POINT) GENERAL NOTE: STOCKTION, CA 95207 <br /> p -5/8" BOLT SWITCHBOARDS, PANELBOARDS, MOTOR CONTROL PANELS, AND METER SOCKET ENCLOSURES WHICH ARE <br /> SCALE: NOT TO SCALE <br /> 02 (Assumed) TRANSFORMER KVA= 300 WTH %Z= 2.25% FAULT Isc(A)= 37010 LIKELY TO REQUIRE EXAMINATION, ADJUSTMENT, SERVICING, OR MAINTENANCE WHILE ENERGIZED, SHALL <br /> LOCK WASHE ® FAULT AT MSB PANEL A PANEL B PANEL C PANEL HVAC UPS/PANEL D PANEL F BE FIELD MARKED TO WARN QUALIFIED PERSONS OF POTENTIAL ELECTRIC ARC FLASH HAZARDS PER <br /> #4 CU(MIN) NEC 110.16. A WARNING LABEL SHALL BE SUFFICIENT, ARC FLASH CALCULATIONS ARE NOT <br /> 2„ ® �0 SOURCE TRANSFORMER MSB MSB MSB MSB MSB PANEL A NECESSARY UNLESS REQUIRED BY THE AUTHORITY HAVING JURISDICTION OR UNLESS THE OWNER <br /> HOLES DRILLED W/NUMBER WIRE SIZE (AWG) 250 310 3/0 3/0 3/0 1 2 SPECIFICALLY REQUIRES IT. THE MARKING SHALL BE LOCATED SO AS TO BE CLEARLY VISIBLE TO <br /> EQUAL & SIZE AS REQUIREDCOPPER OR ALUMINUM CU CU CU CU CU CU CU QUALIFIED PERSONS BEFORE EXAMINATION, ADJUSTMENT, SERVICING, OR MAINTENANCE OF THE <br /> EQUIPMENT. <br /> 5/8" BOL METALLIC OR NONMETALLIC RACEWAY N M M M M M N <br /> 1pft" <br /> INSULATOR FABRICATED FROM FLAME GROUND BAR (COPPER) <br /> INNmOUTRESISTANT FIBERGLASS-REINFORCED LOCK WASHER 1/4" x 4" x 12"L DISTANCE IN FEET(L) 85 53 55 65 64 30 114 <br /> THERMOSET POLYSTER MOLDING COORDINATE EXACT 1 NUMBER OF CONDUCTORS/PHASE (N) 4 1 1 1 1 1 1 <br /> NOTESOL � <br /> ® `BURGER® <br /> COMPOUND (TYPICAL OF 2) LENGTH WITH NUMBER <br /> OF CABLES CONNECTING. PHASE 3 3 3 3 3 1 3 O1 REFER TO THE FAN CONTROL PANEL DIAGRAM LOCATED ON SHEET E8.0. GOD BLESS AMERICA <br /> GROUND BAR IS LOCATED IN (MIN. 21" IN MAIN VOLTAGE (V) 208 208 208 208 208 208 208 <br /> IT CLOSET ON DWG. E4.0 ELECTRICAL ROOM) START FAULT CURRENT Isc (A)- 37,010 27370 27370 27370 27370 27370 13929 O THE FAN CONTROL PANEL IS TO BE LOCATED IN THE HALLWAY ROOM #111. <br /> CONDUCTOR CONSTANT'C' 18594 12844 12844 12844 12844 7293 6044 O3 <br /> TELECOMGROUND BAR DETAIL T FACTOR = 1.732x Lx V(Nx Cx V) 0.352 0.918 0.953 1.126 1.127 1.057 1.650 THE NSS IS RATED AT 30 AMPS, 3 0, 208v, LOCATED INSIDE OF THE ELECTRICAL ROOM. <br /> O`T O PROVIDE A PERMANENTLY INSTALLED LOCK-OPEN DEVICE ON THE INDICATED CIRCUIT BREAKER THAT <br /> SCALE: NOT TO SCALE 'M' MULTIPLIER= 11{1+{] 0.740 0.521 0.512 0.470 0.460 0.4$6 0.377 PROJECT NUMBER <br /> END FAULT(A) 27374 13929 13682 12567 12654 12989 4757 IS CAPABLE OF BEING LOCKED IN THE OPEN POSITION. 190955 <br /> AIC RATED: 65000 65000 65000 65000 65000 65000 65004 O SELF CONTAINED UPS UNIT - AMERICAN POWER CONVERSION IS PROVIDED BY OWNER. <br /> GENERAL CONTRACTOR TO PROVIDE INPUT VOLTAGE: 208VAC, 1 PH, 3W + GND. OUTPUT VOLTAGE: SHEET TITLE <br /> PANEL MSB LOAD SUMMARYGENERAL FAULT CURRENT NOTES: 120/208VAC, 1 PH, 3W + GND. WEIGHT: 598 LBS. DIMENSIONS: 19"W X 27"D X 33"H. <br /> o SUMMARY CONN. LOAD DEMAND DEMAND LOAD MOUNTED: FLOOR 1. HA RTYPE) : 1. CONTRACTOR SHALL COORDINATE WITH THE UTILITY COMPANY PRIOR TO COMMENCEMENT OF WORK. MODEL: APC SYMMETRA LX. PROVIDE 3/4" CONDUIT FROM UPS TO TELEPHONE BOARD. SINGLE LINE <br /> 220.1 <br /> VA AMPS FACTOR KVA AMPS VOLTS: 208/120 2. VIA CONTACTOR/TIME CLOCK 6 VERIFY UTILITY METERING REQUIREMENTS WITH LOCAL UTILITY COMPANY. PROVIDE UTILITY COMPANYC CONTINUOUS(215.2): 9.0 125% 48.7 PHASE/WIRE: 314 2. FAULT CURRENT INFORMATION WILL BE PROVIDED WHEN UTILITY INFORMATION IS AVAILABLE. APPROVED METER CABINET, CTs AND OTHER EQUIPMENT AS REQUIRED. THE C/T & METER, AND MAINDIAGRAM, NOTES <br /> R RECEPTACLE(TABLE 220.44): 10+50%ox10.1 15.0 BUS RATED AMPS:: 1000 AMPS NOTES: 3. CONTRACTOR SHALL COORDINATE WITH UTILITY FOR FAULT CURRENT INFORMATION BEFORE INSTALLING ELECTRICAL EQUIPMENT. CIRCUIT BREAKER CABINET SHALL BE 120OA/3P/4W/1000A, SILVER PLATED COPPER, 65,000 AIC <br /> M MOTORS(430): 6.2 100% 106.2 MAIN TYPE: M.C.B. FULLY RATED. <br /> o K KITCHEN EQUIP. (TABLE 220.56): 222.2 65% 144.4 BUS TYPE: COPPER <br /> N A AIR CONDITIONING(440): 0.0 100% 0.0 FULLY RATED: 65 KAIC O7 BUN GRIDDLE 08 PLUGS DIRECTLY INTO MEAT GRIDDLE 09 VIA INTEGRAL NEMA 15-30R RECEPTACLE. <br /> H HEAT(ELECTRIC)(220Lr� .60): 0.0 0% 0.0 VA SHEET NUMBER <br /> NON-CONTINUOUS(215.2): 3.8 100% 3.8 CONN. PHASE A: 131919 -1% <br /> 0 o LARGEST MOTOR 9.1 25% 2.3 CONN. PHASE B: 134176 -3% <br /> 5-1 Lij 0 TOTAL LOAD 391.21 1086 320.4 889 CONN. PHASE C: 125118 4% <br /> °'o a R Thu Oct 15, 2020 9:47 AM-JG E2mO <br /> z z <br /> � Ck� <br />