Laserfiche WebLink
GENERAL NOTES <br /> PANELBOARD SCHEDULE A SOURCE: PANEL MSB PANELBOARD SCHEDULE C SOURCE: PANEL MSB <br /> A. WALL MOUNTED OUTLETS, JUNCTION BOXES, AUXILIARY SYSTEM OUTLETS EQUIPMENT AND MATERIAL WHICH MAY COME IN CONTACT WITH CUSTOMERS SECTION 1 OF 1 MIN.CONDUIT SIZE: 3/4 SECTION 1 OF 1 MIN.CONDUIT SIZE: 3/4 Architecture / Development <br /> SHALL BE AT +18" VERTICALLY MOUNTED, UNLESS OTHERWISE NOTED. OR EMPLOYEES. 0SERVES N POLES VA WIRE-CONDUIT CK � CK WIRE- CONDUIT VA POLES N SERVES o o SERVES N POLES VA WIRE-CONDUIT CK CK WIRE CONDUIT VA POLES N SERVES 0 <br /> � <br /> B. FLOOR MOUNTED BOXES ON CONDUIT STUBS SHALL BE +6" AFF OR AS AE. PROVIDE 4X4 RECESSED BOXES AND 2X4 PLASTER RINGS FOR DUPLEX T /AMPS # # /AMPS T 0 � T /AMPS # # /AMPS T 0 14901 Quorum Drive <br /> NOTED. 9090 1 A 2 2520 K M 1140 1 A 2 2#12+#1213-3/4"C. 1008 1/20 TOWER LTG/ROOF RCPTS C <br /> RECEPTACLES, DATA AND TELEPHONE OUTLETS. Suite 300 <br /> PANEL F 3/100 6192 4#2+#8G-1 1/2"C. 3 B 4 3#10+#10G-3/4"C. 2520 3/25 E-35 SHAKE MACHINE K M E-83 COOLER COMP 3/20 1140 3#12+#12G-3/4"C. 3 B 4 2#12+#12G-3/4"C. 750 1/20 WATER HTR. PUMP& EXH. FANS M Dallas Texas 75254 <br /> C. ALL CONDUIT SHALL BE RUN CONCEALED UNLESS OTHERWISE NOTED AF. ALL HORIZONTAL DIMENSIONS ARE GIVEN FROM FINISHED WALL TO 5932 5 C 6 2520 K M 1140 5 C 6 2#12+#1213-3/4"C. 1440 1/20 BIRD DETERRENT OUTLETS R <br /> CENTERLINE OF OUTLET, CENTERLINE OF WALL TO CENTERLINE OF OUTLET K SPARE 1/20 7 A 8 2#12+#12G-3/4"C. 1044 1120 E-104 CARBONATORS & DCO K K STEAM CLEANER 2/20 1248 2#12+#12G-3/4"C. 7 A 8 1/20 SPARE Fa ((97 239-8884 <br /> - ALL CONDUIT INSTALLED UNDERGROUND EXTERIOR TO THE BUILDING <br /> OR CENTERLINE OF OUTLET TO CENTERLINE OF OUTLET UNLESS NOTED K E-104 CARBONATORS 1/20 864 2#12+#12G-3/4"C. 9 B 10 2#12+#12G-3/4"C. 1176 1120 E-58 ONION EXHAUST M K 1248 9 B 10 2/30 SPARE H Fax: (972)239-5054 <br /> SHALL BE SCHEDULE 40 PVC OR GALVANIZED RIGID STEEL. OTHERWISE. ALL OUTLETS NOTED +12", + 24", ETC.,TO STUB-OUT OF WALL R E-43&DCO SALAD TABLE 1/20 600 2#12+#12G-3/4"C. 11 C 12 2#12+#12G-31TC. 500 1120 PAY WINDOW R K #81 HIGH PRESS WASHER 1/20 1800 2#12+#12G-3/4"C. 11 C 12 H ISSUE RECORD <br /> - ALL CONDUIT INSTALLED ABOVE GROUND EXTERIOR TO THE BUILDING AT HEIGHT GIVEN FROM FINISHED FLOORNOT TOP OF FINISHED CURB TO M WINDOW FAN FAC-2,FAC-3 1/20 576 2#12+#12G-3/4"C. 13 A 14 2#12+#12G-3/4"C. 1380 1120 E-05 REFRIGERATOR K SPARE 1/20 13 A 14 1/20 SPARE C <br /> ( ) K E-51 POTATO SPINNER 1/20 800 2#12+#12G-3/4"C. 15 B 16 2#12+#12G-3/4"C. 1800 1120 E-118 HOTCHOCO. MACH. K SPARE 1/20 15 B 16 1/20 SPARE DATE DESCRIPTION <br /> SHALL BE WATER TIGHT EMT. CENTERLINE OF OUTLET. ALL OUTLETS NOTED "STUB-UP" TO STUB-OUT OF <br /> - ALL CONDUIT INSTALLED IN THE BUILDING FLOOR SLAB SHALL BE TOP OF FINISHED FLOOR, OR FINISHED CURB, AS THE CASE MAYBE, A K E-17 POTATO PEELER 1/20 1920 2#12+#12G-3/4"C. 17 C 18 2#12+#12G-314"C. 1500 1/20 E-87 SELF SERVE COUNTER K K E-84 REFRIG. SYS B.C.D.E. 2/35 2340 2#8+#10G-3/4"C. 17 C 18 1/20 SPARE URBAN DESIGN PROTOTYPE <br /> SCHEDULE 40 PVC OR GALVANIZED RIGID STEEL. MAXIMUM OF 4" SO AS NOT TO INTERFERE WITH THE INSTALLATION OF K SPARE 1/20 19 A 20 2#12+#12G-3/4"C. 1200 1/20 E-102 POTATO LIFT K K 2340 19 IA 20 2#8+#10G-31TC. 2585 2/40 1 E-22.1 ICE MACH./CONDENSER M 7-10-2020 ISSUED FOR PERMIT <br /> - FOR CONNECTION TO ALL MOTORS, MECHANICAL EQUIPMENT AND FIXTURES AT LOCATION SHOWN. CONTRACTOR TO FIELD VERIFY ALL K SPARE 1/20 21 B 22 2#12+#12G-3/4"C. 1656 1120 E-86&E-96 SODA DISPENSER K SPARE 1/20 21 B 22 2585 M <br /> TRANSFORMERS USE LIQUID-TIGHT FLEXIBLE STEEL CONDUIT (SEALTITE DIMENSIONS. R RECEPTS 1/20 540 2#12+#12G-3/4"C. 23 C 24 2#12+#12G-314"C. 1008 1120 E-96, E-07& DOC K P 2 500 3#12+#12G-3/4"C. 23 C 24 2#8+#10G-3/4"C. 2585 2/40 1 E-22.1 ICE MACH./CONDENSER M <br /> CONDUIT) K 1813 25 A 26 2#12+#12G-3/4"C. 720 1120 E-122 FLY LIGHT& GEN. OUTLETS R M 2100 25 A 26 2585 M <br /> - FOR CONNECTION TO LIGHT FIXTURES LOCATED ABOVE THE CEILING USE AG. ELECTRICAL CONTRACTOR TO PROVIDE CORD AND PLUG FOR ALL ITEMS K #25 3 COMP TURBO WASH 3/25 1813 3#10+#10G-3/4"C. 27 B 28 2#12+#12G-3/4"C. 1700 1120 E-02 COFFEE MAKER K M BOOSTER PUMP (5HP) Q 1 3/35 2100 3#8+#10G-3/4"C. 27 B 28 2#8+#10G-31TC. 2585 2/40 1 E-22.1 ICE MACH./CONDENSER M <br /> FLEXIBLE STEEL CONDUIT. WHERE INDICATED CORD AND PLUG ON EQUIPMENT ELECTRICAL REQUIREMENT K 1813 29 C 30 2#12+#12G-314"C. 1128 1120 E-28 SODA DISPENSER KM 2100 29 C 30 2585 M <br /> - CONDUIT MUST BE CONCEALED ABOVE ACCESSIBLE CEILING WITHIN THE SCHEDULE. K E-42 SALAD TABLE&DCOs 1/20 420 2#12+#12G-3/4"C. 31 A 32 2#12+#12G-3/4"C. 800 1120 TEMPORARY ICE COOLER K 800 2#12+#12G-3/4"C. 31 A 32 2#8+#10G-3/4"C. 2585 2/40 1 E-22.1 ICE MACH./CONDENSER M <br /> BUILDING STRUCTURE WHENEVER POSSIBLE, OR WITHIN CHASES. WHEN K E-10 CHEESE MELTER 2/20 1650 2#12+#12G-3/4"C. 33 B 34 1120 SPARE K SPARE 1120 33 B 34 2585 M <br /> EXPOSED, CONDUIT SHALL BE INSTALLED TIGHT TO WALLS OR CEILING AH. ELECTRICIAN TO PROVIDE MAGNETIC STARTERS AND THERMAL OVERLOAD K 1650 35 C1 36 2#12+#12G-314"C. 1200 1/20 FUTURE FLY FANS M SPARE 1/20 35 C 36 2/40 SPARE <br /> AND INSTALLED IN A NEAT AND WORKMANLIKE MANNER, AND IS TO BE PROTECTION ON ALL MOTORS WHERE REQUIRED. K 2520 37 A 38 2#12+#12G-3/4"C. 500 1/20 WINDOW CONTROL R SPARE 1/20 37 A 38 <br /> READY FOR PAINTING. K E-35 SHAKE MACHINE 3/30 2520 3#10+#10G-3/4"C. 39 B 40 2#12+#12G-3/4"C. 750 1/20 E-53 VVALK IN CUR EVAP. M SPACE 39 B 40 SPACE <br /> - INSTALL ANY SINGLE GROUNDING CONDUCTOR INSIDE OF A PVC Al. SIZE ALL ELECTRICAL JUNCTION BOXES AS REQUIRED PER CEC. PROVIDE ALL K 2520 41 C 42 2#12+#12G-3/4"C. 1650 2/20 E-01 CHEESE MELTER K ISPACE 41 C 42 SPACE <br /> SCHEDULE 40 CONDUIT. JUNCTION BOXES, REFRIGERATION PULL-BOXES AND ELECTRICAL K E-104 CARBONATORS 1/20 864 2#12+#12G-3/4"C. 43 A 44 1650 K <br /> CONVENIENCE OUTLETS LOCATED IN WALLS. FIXTURE FABRICATOR TO LOCATE <br /> D. ALL OUTLETS SHALL BE INSTALLED FLUSH WITH THE BUILDING SURFACES ALL CONVENIENCE OUTLETS AND SWITCHES WHERE PART OF THE FIXTURE, K E-104 CARBONATORS 1/20 864 2#12+#1213-3/4"C. 45 B 46 Z#12+#1213-3/4"C. 540 1/20 DCO AT PREP COUNTER K KEYED NOTES(NT): REVISION RECORD <br /> UNLESS OTHERWISE NOTED. BUT INTERNAL WIRING FOR SUCH BOXES PROVIDED BY ELECTRICAL K E 09A MEAT GRILL 1/20 480 2#12+#1213 3/4"C. 47 C 48 Z#12+#1213 3/4"C. 456 1/20 MISC RECEPTS R o SUMMARY CONN. LOAD DEMAND DEMAND LOAD MOUNTED: SURFACE 1. L=PROVIDE LOCK-ON CIRCUIT 10-14-2020 <br /> CONTRACTOR. WHEREVER ACCESS IS NOT AVAILABLE FOR THE ELECTRICAL K E-09A MEAT GRILL 1/20 480 2#12+#12G-3/4"C. 49 A 50 2#12+#12G-3/4"C. 520 2/15 BACK DOOR FAN FAC-1 M ° KVA AMPS FACTOR KVA AMPS VOLTS: 2081120 BREAKERS 1 CITY COMMENTS <br /> E. THE MINIMUM CONDUCTOR SIZE FOR ALL LINE VOLTAGE APPLICATIONS SHALL CONTRACTOR TO RUN HIS LINES FROM JUNCTION BOXES TO END USAGE IN K E-09A MEAT GRILL 1/20 480 2#12+#12G-3/4"C. 51 B 52 520 M C CONTINUOUS (215.2): 1.0 125% 1.3 PHASE/WIRE: 3/4 2. GFPE=GRD. FAULTPROTECTION <br /> BE #12 AWG. FIXTURES, THE SHEET METAL CONTRACTOR IS TO INSTALL SUITABLE CONDUIT R MONEY CTR-OFFICE 1/20 540 2#12+#12G-3/4"C. 53 C 54 2#12+#12G-314"C. 1128 1120 E-107 FLOOR SCRUBBER K R RECEPTACLE (TABLE 220.44): 2,2 100% 2.2 BUS RATED AMPS:: 200 AMPS ON EQUIPMENT <br /> FOR THE RUNNING OF SUCH LINES. ELECTRICIAN TO PROVIDE AND FIELD SPARE 1/20 55 A 56 2/30 SPARE M MOTORS (430): 31.2 100% 31.2 MAIN TYPE: M.L.O. NOTES: <br /> F. PROVIDE ALL HVAC AND PLUMBING CONTROLS, AND CONTROL WIRING, AS MOUNT ALL JUNCTION BOXES LOCATED IN ACCESS AREAS OF FIXTURES. SPARE 1/20 57 B 1 58 1 K KITCHEN EQUIP. (TABLE 220.56): 9.5 100% 9.5 BUS TYPE: ICOPPER <br /> SPECIFIED IN THE MECHANICAL AND ELECTRICAL SECTION SPECIFICATIONS AND SPARE 1 1 1/20 1 1 59 Cl60 1 1120 1 ISPARE A AIR CONDITIONING (440): 0.0 100% 0.0 FULLY RATED: 22 KAIC <br /> AS INDICATED ON ALL WIRING DIAGRAMS LOCATED IN THE MECHANICAL AJ. FIXTURE FABRICATOR WILL CUT ACCESS HOLES TO CONVENIENCE OUTLETS IN H HEAT(ELECTRIC)(220.60): 0.0 0% 0.0 VA <br /> DRAWINGS. BACK SPLASHES, ETC., BUT ELECTRICAL CONTRACTOR TO PROVIDE KEYED NOTES(NT): NON-CONTINUOUS (215.2): 0.0 100% 0.0 CONN. PHASE A: 16391 -12% <br /> EXTENSION SHIELDS IF REQUIRED. o SUMMARY CONN. LOAD DEMAND DEMAND LOAD MOUNTED: FLUSH 1. HACRTYPE LARGESTMOTOR: 6.3 25% 1.6 CONN. PHASE B: 12993 11% <br /> G. PROVIDE ONE SPARE 3/4" CONDUIT STUB INTO THE ACCESSIBLE CEILING 0 KVA AMPS FACTOR KVA AMPS VOLTS: 208/120 2, VIA CONTACTOR/LIME CLOCK 0 TOTAL LOAD 43.9 137 1 45.7 142 CONN. PHASE C: 14490 1% <br /> SPACE FROM ALL RECESSED PANELBOARDS. AK. PROVIDE POWER AT COMPRESSOR AREAS FOR COMPRESSORS (FOR EXACTG CONTINUOUS(215.2): 18.2 125% 22.8 PHASE/WIRE: 3/4 IWdfw-11eWDATA1\\j\\_2020 Projects\\20.GHAA.027-INOB-Stockton, CA(Urban)\\04 DESIGN DRAWINGS\\02 SCHEDULES&CALCS\\[INOB Stockton-Urban-CA-PANELSx]C Thu Oct 15, 2020 9:31 AM-JG <br /> LOCATION, CHECK WITH ARCHITECT) AS LISTED ON REFRIGERATION PLAN R RECEPTACLE(TABLE 220.44): 4.3 100% 4.3 BUS RATED AMPS:: 225 AMPS NOTES: <br /> H. PROVIDE PULL STRING & RING AT ALL MIS DATA CONDUIT. SHEET. IF AUTOMATIC DEFROST SYSTEMS ARE USED FOR WALK-IN FREEZERS, M MOTORS(430): 7.3 100% 7.3 MAIN TYPE: M.L.O. <br /> PROVIDE 5 WIRE COLOR CODED SERVICE FROM COMPRESSOR TO UNIT. K KITCHEN EQUIP. (TABLE 220.56): 49.2 65% 32.0 BUS TYPE: COPPER <br /> I. ALL FLEX CONDUIT TO BE ANCHORED NO FARTHER THAN 3'-0" O.C. MAX. A AIR CONDITIONING(440): 0.0 100% 0.0 FULLY RATED: 22 KAIC <br /> FLEX CONDUIT TO BE STRETCHED TIGHT BETWEEN ANCHORING POINTS TO AL. PROVIDE REFRIGERATION CONDUIT LINES FROM COMPRESSOR AREA TO PULL H HEAT(ELECI CONDITIONING <br /> 0.0 0% 0.0 VA PANELBOARD SCHEDULE D SOURCE: PANEL MSB <br /> REDUCE SAGS IN CONDUIT. BOXES OR STUB-UPS AS INDICATED ON REFRIGERATION PLAN SHEET. NON-CONTINUOUS(215.2): 0.0 100% 0.0 CONN. PHASE A: 26097 1% SECTION 1 OF 1 MIN. CONDUIT SIZE: 3/4 <br /> CONDUIT TO BE ROUND TRANSITE (OR EQUAL) DIAMETER AS INDICATED, CONN. PHASE B: 25845 2% o SERVES N POLES VA WIRE CONDUIT CK CK WIRE CONDUIT VA POLES N SERVES o <br /> G. THE EXACT LOCATION OF ALL OUTLETS FOR ANY EQUIPMENT FURNISHED WITH MINIMUM BEND IN RADIUS OF 24" AND NO FACTORY "L"'S PERMITTED. <br /> UNDER OTHER SECTIONS OR CONTRACTS SHALL BE OBTAINED FROM THE 0 TOTAL LOAD 79.0 219 66.4 184 CONN. PHASE C: 27085 3% T /AMPS # # (AMPS T PROFESSIONAL SEAL <br /> EQUIPMENT SUPPLIERS. CONNECTION TO SUCH EQUIPMENT SHALL BE UNDER \\\\dfw-file1\\DATA1\\j\\_2020 Projects\\20.GHAA.027-INOB-Stockton,CA(Urban)\\04 DESIGN DRAWINGS\\02 SCHEDULES&CALCS\\[INOB Stockton-Urban-CA-PANELSx]A Thu Oct 15, 2020 9:31 AM-JG C HOOD SUPPRESSION 1 1120 500 2#12+#12G-314"C. 1 A 2 2#12+#12G-3/4"C. 1080 1/20 OFFICE RECEPTACLE R <br /> AM. CONNECT ALL COMPRESSORS COMPLETE WITH DISCONNECT SWITCHES AND R E. LEARNING CENTER 1/20 1000 2#12+#12G-314"C. 3 C 4 2#12+#12G-3/TC. 600 1/20 E-70, E-65 REGISTER R <br /> THIS WORK UNLESS SPECIFICALLY EXCLUDED. OFESS/ <br /> MAGNETIC STARTERS AS REQUIRED. QR 0 <br /> R E-67, PRINTER @GRILL 1120 240 2#12+#1213-314"C. 5 A 6 2#12+#1213-3/4"C. 700 1/20 E-64 @PAY WINDOW R ��� PVL V. <br /> �� <br /> H. REFER TO THE ARCHITECTURAL REFLECTED CEILING PLANS AND ELECTRICAL AN. PROVIDE POWER ON ROOF AND CONNECT ALL EXHAUST FANS AND MAKE-UP R E-67/E-71, PRINTMONITOR 1120 700 2#12+#12G-314"C. 7 C 8 2#12+#12G-3/4"C. 1000 1/20 FC-1, ORD. CNTR. REGISTS R �� �f F2 <br /> LIGHTING PLANS FOR THE LOCATION OF ALL LIGHT FIXTURES. AIR FANS AND LOCATE SWITCHES WITH RED PILOT LIGHT AS DIRECTED BYPANELBOARD SCHEDULE B SOURCE: PANEL MSB R E-71, E67& E-71 REAR DR. 1/20 600 2#12+#12G-314"C. 9 A 10 3#12+#12G-3/4"C. 500 1120 1 FIRE CONTROL PANEL R <br /> R E-70, E-71 & E-68 1120 700 2#12+#12G-314"C. 11 C 12 2#12+#12G-3/TC. 840 1/20 E-70,E71,E-65&E-71.1 R r, <br /> VENTILATION CONTRACTOR. DISCONNECT SWITCHES TO BE MOUNTED No. E13453 <br /> I. ALL CONDUCTORS SHALL BE OF TYPE THHN OR THWN COPPER RATED AT 90CONVENIENT TO HOODS. SECTION 1 OF 1 MIN.CONDUIT SIZE: 3/4 R E-71,67, PR. @ GRILL 1120 500 2#12+#12G-3/4"C. 13 A 14 2#12+#12G-3/TC. 360 1/20 TELEPHONE R <br /> o SERVES N POLES VA WIRE CONDUIT CK CK WIRE CONDUIT VA POLES N SERVES o * EXP. 09/30/22 <br /> DEGREES CELSIUS. ALL TERMINATION POINTS ARE TO BE RATED AT 90 0 0 R SPARE 1120 15 C 16 1/20 SPARE R <br /> DEGREES CELSIUS. A0. AT KITCHEN AND BACK OF HOUSE PROVIDE STAINLESS STEEL COVER PLATES " T /AMPS # # !AMPS T 0 R SECURITY RACK 1120 500 2#12+#12G-3/4"C. 17 A 18 2#12+#12G-3/4"C. 500 1/20 HME R `P�q �FCTR\G O�\P <br /> FOR ANY FULLY OR PARTIALLY EXPOSED PULL-BOXES AND/ OR ELECTRICAL C LTGS DINING AREA 1/20 354 2#12+#12G-3/4"C. 1 A 2 2#12+#12G-34'C. 1322 1120 LTGS RR RM/LOCKER,EF-1 C SPARE 1120 19 C 20 1/20 SPARE TF OF CALF <br /> J. ALL TELEPHONE WIRING CONDUIT HOMERUNS ARE TO BE TERMINATED AT THE ACCESS BOXES AND PROVIDE STAINLESS STEEL COVER PLATES FOR ALL C LTGS DINING AREA 1/20 250 2#12+#12G-3/4"C. 3 B 4 2#12+#12G-3/4"C. 639 1120 LTGS KITCHEN C R SECURITY/SPLICE BOX 1120 500 2#12+#12G-3/4"C. 21 A 22 2#12+#12G-3/4"C. 200 1/20 LED/VIDEO MONITOR R 10/15/20 <br /> TELEPHONE BACKBOARD. CONVENIENCE OUTLETS, JUNCTION BOXES AND SWITCH PLATES. AT DINING C LTGS PENDANT 1/20 120 2#12+#12G-3/4"C. 5 C 6 2#12+#12G-3/4"C. 672 1120 LTGS KITCHEN C R FUTURE MONITOR BOARD 1120 500 2#12+#12G-3/4"C. 23 C 24 2#12+#12G-3/4"C. 500 1/20 MIS ROOM R <br /> ROOM AND RESTROOM COVER/PLATES ARE TO MATCH WALL OR CEILING C LTGS RECESSED 1/20 360 2#12+#12G-3/4"C. 7 A 8 2#12+#12G-3/TC. 218 1120 LTGS COOLER C R E-93 ANSUL POWER 1/20 500 2#12+#12G-3/4"C. 25 A 26 2#12+#12G-3/TC. 500 1/20 REC. DRESSING RM. R <br /> K. ALL PENDANT LIGHT FIXTURE STEMS SHALL BE APPROVED FOR EARTHQUAKE COLOR. DO NOT PAINT COVER PLATES. C LTGS NEON/PLANTER 1120 155 2#12+#12G-3/4"C. 9 B 10 2#12+#12G-314"C. 200 1120 LTGS OFFICE/DRESSING C R E-66 HOOD CONTROL 1120 500 2#12+#12G-314"C. 27 C 28 2#12+#12G-3/4"C. 500 1/20 REC. DRESSING RM. R <br /> DURABILITY. C INTERIOR MENU BOARD 1120 500 2#12+#12G-3/4"C. 11 C 12 2120 SPARE C SPARE 1120 29 A 30 1/20 SPARE <br /> L. LIGHT FIXTURE OUTLET BOXES SHALL BE A MINIMUM SIZE OF 4" SQUARE BY AP. THE SYMBOLS ON THE ELECTRICAL PLAN INDICATE LOCATION AND TYPE OF C SPARE 2/20 13 A 14 C SPARE 1120 31 C 32 1/20 SPARE <br /> CONNECTION ONLY. ELECTRICIAN TO PROVIDE CIRCUITS AND CONDUITS RUNS C 15 B 16 2#12+#12G-314"C. 1200 1120 BORDER LED(SIDE) C SPARE 1/20 33 A 34 1/20 ISPARE <br /> 2 1/8" DEEP. AS REQUIRED. C LTGS BLDG. 1120 368 2#12+#12G-314"C. 17 C 18 2#12+#12G-314"C. 1200 1120 BLDG. SIGN (SIDE) C SPARE 1/20 35 C 36 1/20 SPARE <br /> C LTGS PATIO CANOPY 1120 150 2#12+#12G-3/4"C. 19 A 20 2#12+#12G-314"C. 1200 1120 PYLON MONUMENT C SPARE 1120 37 A 38 1/20 SPARE Ir <br /> M. PROVIDE SUITABLE CLAMPS FOR ALL VERTICAL CONDUITS NOT SPACED MORE <br /> AQ. ELECTRICAL REQUIREMENT PLANS ARE PROVIDED FOR THE SOLE PURPOSE OF C PARKING LOT LTGS 2/20 555 SEE DWG. E1.0 21 B 22 2#12+#12G-314"C. 75 1120 LTGS SECURITY C SPARE 1120 39 C 40 1/20 SPARE kk,.-t M <br /> THAN 24" APART. INDICATING THE LOCATION OF OUTLETS, TYPE OF CONNECTION AND C 555 23 C 24 2120 SPARE C ISPARE 1 1 1/20 1 1 41 1 Al42 1 1/20 SPARE engineering consultants <br /> ELECTRICAL LOAD. SUB-CONTRACTORS MUST COMPLY WITH ALL CODES C LTGS DRIVE THRU CANOPY 1120 75 2#12+#12G-3/4"C. 25 A 26 C 8 <br /> N. ALL ELECTRICAL EQUIPMENT INSTALLED EXTERIOR TO THE BUILDING SHALL BE RELATED TO THE INSTALLATION, WIRING AND HOOK-UP OF EQUIPMENT. C PARKING LOT LTGS 2/20 465 SEE DWG. E1.0 27 B 28 2#12+#12G-314"C. 500 1120 EXTERIOR MENU BOARD C KEYED NOTES(NT): 14901 Quorum Dr. #565 Dallas, TX 75254 <br /> RATED AS WEATHERPROOF, NEMA 3R. C 465 29 C 30 1120 FUTURE LANDSCAPE L.V. LGT C o SUMMARY CONN. LOAD DEMAND DEMAND LOAD MOUNTED: FLUSH 1. L=PROVIDE LOCK-ON CIRCUIT rtmassociates.com 1 972.387.3500 <br /> AR. WHERE THE SYMBOLS ARE INDICATED FOR A SOLID CONNECTION, A 4'-0" C BORDER LED(SIDE) 1120 900 2#12+#12G-3/4"C. 31 A 32 2#12+#12G-314"C. 900 1120 BORDER LED(REAR) C o KVA AMPS FACTOR KVA AMPS VOLTS: 208/120 BREAKERS <br /> 0. ALL RECEPTACLES INSTALLED EXTERIOR TO THE BUILDING SHALL BE RATED SECTION OF FLEX CONDUIT SHOULD BE STUBBED-OUT AT THE PROPER <br /> AS GFCI TYPE. ALL RECEPTACLES LOCATED IN THE KITCHEN AREA SHALL BE LOCATION AND SHALL BE CONNECTED TO "J" BOXES LOCATED INA C BLDG. SIGN (SIDE) 1/20 1200 2#12+#1213-3/4"C. 33 B 34 2#12+#1213-3/4"C. 900 1120 SHOW WINDOW RCEPTS C C CONTINUOUS (215.2): 0.5 125% 0.6 PHASE/WIRE: 1/3 <br /> CONVENIENT POSITION ON EQUIPMENT AFTER EQUIPMENT HAS BEEN PLACED C BORDER LED(FRONT) 1/20 900 2#12+#1213-3/4"C. 35 C 36 1120 SPARE C R RECEPTACLE (TABLE 220.44): 13.5 10+50%x3.5 11.8 BUS RATED AMPS:: 125 AMPS NOTES: <br /> GFCI TYPE. ALL RECEPTACLES IN OTHER AREAS WITHIN 6' OF A SINK SHALL PROTOTYPE VERSION <br /> BE GFCI. C BLDG. SIGN (FRONT) 1/20 1200 2#12+#1213-3/4"C. 37 A 38 1120 SPARE C M MOTORS (430): 0.0 100°1° 0.0 MAIN TYPE: M.L.O. PROVIDE IG BUS <br /> IN POSITION. IF LOCAL CODES DO NOT PERMIT THIS METHOD, PLEASE SPARE 1 1 1120CONTACT K.E.C. IMMEDIATELY. 1 139 B 40 2#12+#12G-314"C. 400 1120 EXT. DIRECTION SIGNS C 16U.2.61 <br /> K KITCHEN EQUIP. (TABLE 220.56): 0.0 100°1° 0.0 BUS TYPE: COPPER <br /> P. LOCATE ALL LIGHTING OUTLETS IN THE MECHANICAL ROOMS AFTER THE C I LCP POWER 1 1 1120 1 500 2#12+#12G-3/4"C. 1 41 1 C1 42 2#12+#12G-314"C. 720 1 1120 ILIGHTPOLE RECEPTACLE IC A AIR CONDITIONING (440): 0.0 100% 0.0 FULLY RATED: 22 KAIC <br /> DUCTS AND PIPES HAVE BEEN INSTALLED. AS. PROVIDE LOCK-OUT DEVICES ON ALL BREAKERS FOR CLOCKS, H HEAT(ELECTRIC)(220.60): 0.0 0% 0.0 VA PROJECT NAME <br /> REFRIGERATION, CONTROL WIRING AND FIRE EXHAUST SYSTEMS CONTROLS. KEYED NOTES(NT): NON-CONTINUOUS (215.2): 0.0 100% 0.0 CONN. PHASE A: 7180 -2% <br /> Q. LIGHTING, POWER, TELEPHONE, AND COMMUNICATIONS OUTLETS SHALL NOT PROVIDE ROUGH-IN TO LOCATIONS AS SHOWN ON THIS PLAN AND AS o SUMMARY CONN. LOAD DEMAND DEMAND LOAD MOUNTED: FLUSH 1. HACRTYPE IN-N-OUT <br /> BE PLACED BACK TO BACK. SHOWN FOR CONDUITS ON THE REFRIGERATION AND KITCHEN PLAN. 0 KVA AMPS FACTOR KVA AMPS VOLTS: 208/120 2. VIA CONTACTOR/TIME CLOCK 0 TOTAL LOAD 14.0 67 12.4 35 CONN. PHASE C: 6840 2% <br /> C CONTINUOUS (215.2): 19.2 125% 24.0 PHASE/WIRE: 314 Illldfw-fleWDATAWj1\_2020 Prcjects1120 GHAA.027-INOB-Stockton, CA(Urban)M4 DESIGN DRAWINGS\\02 SCHEDULES&CALCS\\[INOB Stockton-Urban-CA-PANELSx]D Thu Oct 15, 2020 9:31 AM-JG BURGER <br /> R. ALL CONDUIT SHALL HAVE A EQUIPMENT GROUNDING CONDUCTOR INSTALLED AT. PROVIDE ALL ELECTRICAL MATERIALS AND LABOR TO MAKE FINAL R RECEPTACLE (TABLE 220.44): 0.0 100% 0.0 BUS RATED AMPS:: 225 AMPS NOTES: <br /> AND SIZED PER CODE. CONNECTIONS TO ALL EQUIPMENT AND INTERCONNECTION OF EQUIPMENT, M MOTORS(430): 0.0 100% 0.0 MAIN TYPE: M.L.O. <br /> CONTROLS, ETC. K KITCHEN EQUIP. (TABLE 220.56): 0.0 100% 0.0 BUS TYPE: COPPER <br /> S. PROVIDE PROTECTION FROM PHYSICAL DAMAGE FOR MAIN SWITCHBOARD A AIR CONDITIONING(440): 0.0 100% 0.0 FULLY RATED: 22 KAIC PANELBOARD SCHEDULE F SOURCE: PANEL A <br /> 'MSB", PANELBOARDS AND OTHER ELECTRICAL EQUIPMENT, AS PER CEC AU. SPEAKER OUTLET (VERIFY W / OWNER). FURNISH AND INSTALL CONDUITS, H HEAT(ELECTRIC)(220.60): 0.0 0% 0.0 VA SECTION 1 OF 1 MIN. CONDUIT SIZE: 3/4 STOCUON <br /> 110-27(B). WIRING ACCESSORIES AS REQUIRED FOR SOUND SYSTEM. NOWCONTIN000S (215.2): 0.0 100% 0.0 CONN. PHASE A: 6679 4% o SERVES N POLES VA WIRE-CONDUIT CK CK WIRE-CONDUIT VA POLES N SERVES o <br /> CONN. PHASE B: 6539 <br /> T. 4" SQ., J BOX W/ 3/4" C.O. TO EXTEND ABOVE CEILING FOR FIRE AV. 1 1/2" CO W/ PULL WIRE TO DRIVE THRU WINDOW INTERCOM SYSTEM0TOTALLOAD 19.2 53 24.0 67 CONN. PHASE C: 6000 6%° C LIGHTING T A20S 138 2#12+#12G-3/4"C. # A 2 840 AMPS T M CALIFORNIA <br /> SUPPRESSION SYSTEM. VERIFY WITH OWNER PRIOR TO ROUGH-IN. \\\\dfw-file/\\DATA1\\j\\_2020 Projects\\20.GHAA.027-INOB-Stockton,CA(Urban)\\04 DESIGN DRAWINGS\\02 SCHEDULES&CALCS\\[INOB Stockton-Urban-CA-PANELSx]B Thu Oct 15, 2020 9:31 AM-JG R RECEPTACLES 1/20 360 2#12+#12G-3/4"C. 3 B 4 3#12+#12G-3/4"C. 840 3/20 3 TRASH COMPACTOR M <br /> AVE <br /> U. ALL CONDUITS THAT ENTER THE REFRIGERATED AREA SHALL BE FILLED WITH AW. DRIVE-THRU WIRING DIAGRAM IS FOR REFERENCE ONLY. VERIFY EXACT R IRRIGATION CONTROL 1/20 100 2#12+#12G-3/4"C. 5 C 6 840 M 5202 PACIFIC C ELECTRIC VEHICLE CHARGER 2/40 3120 SEE NOTE ON DWG. E1.0 7 A 8 1872 C V <br /> AN APPROVED SEALING COMPOUND AT AN ACCESSIBLE LOCATION ON THE REQUIREMENTS W/ OWNER PRIOR TO ROUGH-IN. (BY OWNER) C (FUTURE USE) 3120 9 B 10 3#10+#1oG-3/4"C. 1872 3/30 1 DUPLEXSEWER PUMPS C STOCKTION CA 95207 <br /> WARMER SIDE OF THE COOLER WALLS PRIOR TO THE CONDUIT ENTERING THE C ELECTRIC VEHICLE CHARGER 240 3120 SEE NOTE ON DWG. E1.0 11 C 12 1872 1C <br /> COLDER SECTION. AX. CIRCUIT BREAKERS UTILIZED IN SWITCHING LIGHTING FIXTURES AT THE PANELBOARD SCHEDULE HVAC SOURCE: PANEL MSB C (FUTURE USE) 3120 13 A 14 1/20 SPARE <br /> PANELS IN LIEU OF LOCAL WALL SWITCHES SHALL BE APPROVED FOR THE SECTION 1 OF 1 MIN. CONDUIT SIZE: 3/4 15 B 16 1/20 SPARE <br /> V. PROVIDE ISOLATED GROUND ORANGE RECEPTACLE FOR P.O.S. SYSTEM-HOME PURPOSE. CIRCUIT BREAKERS SHALL BE U.L. LISTED AND MARKED "SWD" o SERVES N POLES VA WIRE CONDUIT CK CK WIRE- CONDUIT VA POLES N SERVES o 17 C 18 1/20 SPARE <br /> RUN. SEPARATE NEUTRAL AND GROUND WIRE TO EACH OUTLET. DO NOT AND SHALL BE SUITABLE FOR SWITCHING LIGHTING FIXTURES. 0 1 0 19 A 20 <br /> COMBINE WITH OTHER HOME RUNS. 1 T /AMPS # # /AMPS T <br /> AY. PROVIDE CAPS & CORDS WHERE REQUIRED FOR FOOD SERVICE EQUIPMENT M 5040 1 A 2 5040 M <br /> W. 3/4" C.O. W/ PULL WIRE UP TO DRIVE THRU MENUBOARD DETECTOR LOOP. M #1 3150 5040 3#6+#10G-1"C. 3 B 4 3#6+#10G-1"C. 5040 3/50 AC#2 M KEYED NOTES(NT): <br /> o SUMMARY CONN. LOAD DEMAND DEMAND LOAD MOUNTED: SURFACE 1. HACRTYPE <br /> NCR COMM. CABLE SHALL BE FURNISHED BY OWNER & INSTALLED BY M 5040 5 C 6 5040 M 0 <br /> AZ. OBTAIN A SET OF FOOD SERVICE EQUIPMENT DRAWINGS FOR VERIFICATION OF KVA AMPS FACTOR KVA AMPS VOLTS: 208/120 2. VIA CONTACTOR/TIME CLOCK INNmOUT <br /> ELECTRICAL CONTRACTOR. ELECTRICAL REQUIREMENTS. M -1 ON ROOF 2130 1872 2#10+#1013-314"C. 7 A 8 11280 M1872 9 B 10 3#1+#6G-1 112"C. 11280 31125 AC#3 M C CONTINUOUS (215.2): 18.2 125% 22.8 PHASE/WIRE: 3/4 3. PROVIDE LOCKABLE DEVICE C.B. <br /> X. INTERLOCK HOOD MOUNTED "PUSH" FAN SWITCH W/ EXHAUST FAN. REFER BA. TYPICAL INSTALLATION OF SIMPLEX AND DUPLEX RECEPTACLES SHALL HAVE PACE 11 C 12 11280 M R RECEPTACLE(TABLE 220.44): 0.5 100% 0.5 BUS RATED AMPS:: AMPS "OFF POSITION" \BURGER <br /> TO CONTROL DIAGRAM. THE GROUND PLUG ORIENTED DOWN ON VERTICAL MOUNTED RECEPTACLES. SPACE 13 A 14 SPACE M MOTORS (430): 2,5 100% 2.5 MAIN TYPE: MM..C.B. GENERAL NOTE: <br /> SPACE 15 B 16 SPACE K KITCHEN EQUIP. (TABLE 220.56): 0.0 1000/0 0.0 BUS TYPE: ICOPPER PROVIDE IN NEMA 3R ENCLOSURE <br /> Y. INTERLOCK FLY FAN W/ DOOR ACTIVATED SWITCH. BB. RACEWAYS, CABLE ASSEMBLIES, BOXES, CABINETS, AND FITTINGS SHALL BE SPACE 17 C 18 SPACE A AIR CONDITIONING (440): 0.0 100% 0.0 FULLY RATED: 10 KAIC GOD BLESS AMERICA <br /> SECURELY FASTENED IN PLACE. SUPPORT WIRES THAT DO NOT PROVIDE H NON-CHEAT NTNUC)(220.60): 0.0 0% 0.0 VA <br /> Z. ALL RECEPTACLES IN KITCHEN & PREP. AREAS SHALL BE RATED FOR 20 SECURE SUPPORT SHALL NOT BE PERMITTED AS THE SOLE SUPPORT. KEYED NOTES(NT): NON coNllNuous (215.2): o.0 1oo°i° o.o CONN. PHASE A: 9090 29% <br /> AMPS. ALL 120 VOLT OUTLETS NOT DESIGNATED WITH SPECIFIC LOADS TO BE SUPPORT WIRES AND ASSOCIATED FITTINGS THAT PROVIDE SECURE SUPPORT o SUMMARY CONN. LOAD DEMAND DEMAND LOAD MOUNTED: SURFACE 1. HACRTYPE CONN. PHASE B: 6192 12% <br /> RATED 20 AMPS. ALL 208 VOLTS OUTLETS NOT DESIGNATED WITH SPECIFIC AND THAT ARE INSTALLED IN ADDITION TO THE CEILING GRID SUPPORT WIRES 0 0 TOTAL LOAD 21.2 76 25.8 72 CONN. PHASE on 5932 16% <br /> 0 KVA AMPS FACTOR KVA AMPS VOLTS: 2081120 2. VIA CONTACTOR/TME CLOCK \\Ndfw-filet\\DATA111j11_2020 Projects\120.GHAA.027-INOB-Stockton, CA(Urban)1\04 DESIGN DRAWINGS\\02 SCHEDULES&CALCSI\[INOB Stockton5932 <br /> -PANELSx]F Thu Oct 15,2020 9:31 AM-JG <br /> LOADS TO BE RATED AT 3/4 HP. SHALL BE PERMITTED AS THE SOLE SUPPORT. WHERE INDEPENDENT C CONTINUOUS (215.2): 0.0 125% 0.0 PHASE/WIRE: 314 <br /> SUPPORT WIRES ARE USED, THEY SHALL BE SECURED AT BOTH ENDS. CABLE R RECEPTACLE (TABLE 220.44): 0.0 100% 0.0 BUS RATED AMPS:: 200 AMPS NOTES: PROJECT NUMBER <br /> AA. CONFORM TO SECTIONS 430 AND 440 OF THE NATIONAL ELECTRICAL CODE AND RACEWAYS SHALL NOT BE SUPPORTED BY CEILING GRIDS. M MOTORS (430): 67.8 100% 67.8 MAIN TYPE: M.L.O. 190955 <br /> (N.E.C) SPECIFICATIONS PERTAINING TO CONNECTION FOR EQUIPMENT WITH K KITCHEN EQUIP. (TABLE 220.56): 0.0 100% 0.0 BUS TYPE: COPPER PANELBOARD SCHEDULE NOTES: <br /> MOTORS FOR PERMANENTLY WIRED APPLIANCES AND CORD CONNECTED BRANCH CIRCUITS 3% VOLTAGE DROP CU WIRE MAXIMUM DISTANCE A AIR CONDITIONING (440): 0.01 100% 0.0 FULLY RATED: 65 KAIC <br /> APPLIANCES AND EQUIPMENT. feet H HEAT(ELECTRIC)(220.60): 0.0 0% 0.0 VA 1 . TURN ALL SPARE CIRCUIT BREAKERS TO "OFF" POSITION AT COMPLETION OF WORK. SHEET TITLE <br /> VOLT 1(: 120 120 120 208 208 208 NON-CONTINUOUS (215.2): 0.0 100% 0.0 CONN. PHASE A: 23232 -3% <br /> AB. PROVIDE ALL REQUIRED MOTOR OVERCURRENT PROTECTION DEVICES LARGESTMOTOR 6.3 25% 1.6 CONN. PHASE B: 23232 -3% 2. PROVIDE TYPED SCHEDULE FOR PANELBOARDS UTILIZED AT COMPLETION OF PROJECT PANEL SCHEDULES, <br /> REQUIRED UNLESS THE DEVICES ARE PROVIDED WITH THE EQUIPMENT. AMP : 5 10 15 5 10 15 0 TOTAL LOAD 67.8 188 69.4 193 CONN. PHASE C: 21360 6% INDICATING ACTUAL AS-BUILT CONDITIONS. <br /> E #12 AWG 185 90 60 320 160 105 \\dfw-file t\\DATA 1\\j\\_2020 Projects\\20.GHAA.027-INOB-Stockton, CA(Urban)\\04 DESIGN DRAWINGS\\02 SCHEDULES&CALCS\\[INOB Stockton-Urban-CA-PANELSx]HVA Thu Oct 15, 2020 9:31 AM-JG LOAD SUMMARY <br /> AC. SHALLBEPERMITTEDRTOQBE ^LOCATEDRWTHINOTHE DEDICATEDQSPACENABOVE <br /> a° #10 AWG 290 140 95 500 250 170 AND GENERAL NOTES <br /> THE ELECTRICAL EQUIPMENT, AS PER CEC 110-26(F). <br /> D #8 AWG 450 230 155 800 400 270 <br /> N AD. CONTRACTOR SHALL DEBUR AND FILE ALL SHARP EDGES OF INSTALLED #6 AWG 730 370 240 1250 640 420 <br /> SHEET NUMBER <br /> #4 AWG 1150 580 390 2000 1000 680 <br /> M9U <br /> 0 0 #3 AWG 1450 730 490 2550 1270 850 <br /> 0 0 #2 AWG 1830 920 610 3200 1600 1060 <br /> W E2ml <br /> z Z #1 AWG 2300 1150 770 4000 2000 1350 <br /> � Ck� <br /> � Cl- <br />