Laserfiche WebLink
x - - - - - - - - - - - x - - - - - - - - - - - x x - - - - - <br /> i <br /> PLUMBING NOTES <br /> x <br /> 1. UTILITY LOCATIONS ARE APPROXIMATE & FOR INFORMATION PURPOSES <br /> CEENTETE R <br /> g' ONLY. KITCHEN EQUIPMENT CONTRACTOR SHALL COORDINATE WITH <br /> ° Q PLUMBING ENGINEERING DRAWINGS & PROVIDE DIMENSIONED UTILITY Architecture / Development <br /> Lj LJ NROUGH-IN PLANS. <br /> n-I-0 <br /> 14901 Quorum Drive <br /> i 2. UTILITY REQUIREMENTS, EQUIPMENT DIMENSIONS & UTILITY Suite 300 <br /> INTERCONNECTIONS ARE BASED ON MANUFACTURER& MODEL NUMBER <br /> AS INDICATED ON PLANS & IN WRITTEN SPECIFICATIONS, SECTION 11400. Dallas Texas 75254 <br /> Ph: (972)239-8884 <br /> j 3. KITCHEN EQUIPMENT CONTRACTOR WILL NOT BE RESPONSIBLE TO Fax: (972)239-5054 <br /> I FURNISH PLUMBING COMPONENTS & FIXTURES SUCH AS TEES, MIXING <br /> I VALVES, ELBOWS, SHUT-OFF VALVES, COUPLINGS & FITTINGS OTHER ISSUE RECORD <br /> I THAN THOSE FURNISHED AS STANDARD WITH EQUIPMENT OR EXCEPT AS DATE DESCRIPTION <br /> D L 21" 1 SPECIFIED. URBAN PROTOTYPE <br /> I 7-7-2020 ISSUED FOR PERMIT <br /> o I 4. FINAL CONNECTIONS TO EQUIPMENT SHALL BE RESPONSIBILITY OF <br /> ❑e � j PLUMBING CONTRACTOR. <br /> ❑o ----� <br /> O 5. MECHANICAL ENGINEER TO DETERMINE, PER APPLICABLE CODES, WASTE <br /> EE:� OUTLET REQUIREMENTS, DIRECT OR INDIRECT, FOR FOOD PREPARATION <br /> & UTILITY SINKS & PROVIDE PROPER WASTE RECEPTACLES, AS REQUIRED. <br /> 550S162-43 12 <br /> IFF - <br /> -- '' -� 6. MECHANICAL ENGINEER TO DETERMINE, PER APPLICABLE CODES, SIZE <br /> AND LOCATION OF GREASE INTERCEPTORS. KITCHEN EQUIPMENT <br /> w CONTRACTOR SHALL COORDINATE WITH PLUMBING ENGINEERING <br /> N j j DRAWINGS. <br /> II <br /> 0 I 7. REFER TO PLUMBING ENGINEERING DRAWINGS FOR LOCATIONS OF <br /> P-86 P-87 GENERAL PURPOSE FLOOR DRAINS. <br /> * P-87 P-87 P-86 REVISION RECORD <br /> (rjl 26" 16" T 20" 16 14" 9A I 8. FLOOR SINKS & FUNNEL FLOOR DRAINS ARE INDICATED WHERE <br /> RECOMMENDED TO ACCOMMODATE FOODSERVICE EQUIPMENT. <br /> ❑ STRUCTURAL& PLUMBING ENGINEERS SHALL REVIEW& COORDINATE. <br /> I I <br /> ®7 <br /> 9. PLUMBING CONTRACTOR SHALL EXTEND INDIRECT WASTE OUTLETS FROM <br /> Ir--- I EQUIPMENT TO FLOOR SINK OR FUNNEL FLOOR DRAIN, AS INDICATED. <br /> Lj ID[ElU U 0 Li U D <1 I- <br /> P-49 � '" <br /> II i 0 <br /> 2xs 2 <br /> I I 10. PLUMBING CONTRACTOR SHALL PROVIDE & INSTALL WATER PRESSURE <br /> °D REDUCING VALVES FOR WATER PRESSURES IN EXCESS OF 50 PSI, UNLESS <br /> P 17 0 OTHERWISE INDICATED. <br /> REQUIREMENTS THESE AREAS: o <br /> REFER ENGINEERING PLUMBING ---J L 11. ALL COOKING EQUIPMENT MUST BE SHUT-OFF AUTOMATICALLY, PER NFPA <br /> CODES, UTILIZING SHUNT-TRIP BREAKERS OR CONTACTORS, AS <br /> / PLANS. P-09A 4" ON FURNISHED & INSTALLED BY ELECTRICAL CONTRACTOR, OR GAS SUPPLY <br /> N CENTER SHUT-OFF VALVES, AS FURNISHED BY KITCHEN EQUIPMENT CONTRACTOR <br /> 01 1 I & INSTALLED BY PLUMBING CONTRACTOR. <br /> F_ -1JI Di P-23 'bo <br /> ENON � <br /> N P_ 3A �roRAGL b I 12. PLUMBING ENGINEER SHALL DETERMINE INCOMING BUILIDING WATER <br /> TEMPERATURE AND PRESSURE TO DETERMINE PROPRER SIZE OF HOT <br /> 4" ON DP-81A CABINET <br /> ABOVE I WATER BOOSTER HEATER FOR DISHMACHINE. <br /> CENTER / 1 <br /> N p_15 C, 1F P-03 1 13. 13. PLUMBING CONTRACTOR SHALL PROVIDE INTERCONNECTING <br /> i�� I INSULATED HOT WATER LINE FROM BOOSTER HEATER TO DISHMACHINE. <br /> 2x6 • 1 <br /> L L J <br /> WALL MOU T 14. 14. P-104 FILTER LINE OUT AT 1". BOTH 1" STUBS FROM CEILING ARE TO <br /> T T x N CHEM CAE�NET <br /> OILP-03A HAVE 3/4" NIPPLES, 12" DOWN FROM CEILING. <br /> STORAGE OIL�I �I PROFESSIONAL SEAL <br /> 2x6 L TANKS ADN] 1" <br /> 011 LEGEND - PLUMBING CONNECTIONS <br /> d C J P-09A C HW-HOT WATER, OR CW-COLD WATER <br /> O =b GE <br /> RACK RACK RACK RACK O GAS <br /> - P-22 P-25 • WASTE, DIRECT-CONNECTED UNLESS NOTED SE 30 r21 <br /> (CHEM %� � ROOF MOUNTED EQUIPMENT: SEE "OPEN HUB" A <br /> CABINETADDITIONAL INFORMATION ON � FLOOR DRAIN aF <br /> L ENGINEERING PLUMBING PLANS. <br /> P-02 ti+ 8" ON FLOOR DRAIN W/ATTACHED FUNNEL <br /> CENTER <br /> - I I FLOOR SINK WITH HALF GRATE UNLESS <br /> N <br /> -7F-- NOTED OTHERWISE <br /> P- 3A L- J <br /> 31" ---- FIELD CONNECTIONS <br /> - - - - - - - - � - - - - - - - - - - THREE DOOR P-81 P-85 P-09A <br /> F -1 4" ON <br /> 2x6 �� CENTER MEAT COOLIE <br /> 26 26 L _ GENERAL NOTES PROTOTYPE VERSION <br /> i2Xa ------- 16U.2.61 <br /> L❑_ <br /> 1. ALL SODA, REFRIGERATION AND FILTERED WATER CHASES SHALL BE <br /> PLUMBING SCHEDULE INSTALLED WITH FULL SWEEP ELBOWS NO 45 DEGREE OR 22.5 DEGREE PROJECT NAME <br /> (1/8TH OF 1/16TH BENDS)WILL BE ALLOWED - NO EXCEPTIONS. <br /> z z z IN-N-OUT <br /> W W � w Q Q Q 2. SECURE CHASE INSIDE WALLS WITH BLOCKING AND FORMED STRAPS. NO <br /> ~ Q H H D <br /> Q ^ > ^ 0 ^ 0 PLUMBING METAL TAPE WILL BE ALLOWED. BURGER <br /> Z z > Z z U Z Z � z Z = z 3. ALL REFRIGERATION SWEEPS THAT PENETRATE WALLS SHALL BE CUT OFF <br /> p p W U U `- `- <br /> ITEM J W J W W W DC W W W W W (n W C/) W 1/4" BEYOND SCHEDULED WALL FINISH PRIOR TO INSTALLATION OF <br /> NO O En O Q O 6 O Q o � o � o Q (D C Q EQUIPMENT CATEGORY PLUMBING REMARKS REFRIGERANT LINES. <br /> P-01 0.25" 16" CHEESE MELTER USE REVERSE OSMOSIS WATER; UTILIZE UNDERSLAB CONDUIT. 4. ALL REFRIGERATION CHASES SHALL BE SECURED WITH THE OPENINGS 90 STOCIffON <br /> DEGREES TO THE WALL FINISH. <br /> P-02 0.25" 16" COFFEE/TEA MAKER USE FILTERED WATER. CALIFORNIA <br /> 5. CONTRACTOR SHALL FINISH DRYWALL OR OTHER SURFACE TIGHT TO PVC <br /> P-03 1 12" 05' 12" 1 1/2" PREP SINK ONION SINK RUN DRAIN LINE TO FLOOR SINK. CHASE AND CAULKED WITH SILICONE. <br /> P-03A 1" 12" PREP SINK/ONION SINK AREA USE FILTERED WATER; MOUNT AT SST BACKSPLASH AT PRE-DRILLED HOLES. REDUCE TO 3/8" AT SPOUT. 6. REFRIGERATION LINES SETS ARE GENERALLY LOCATED AT 22"ABOVE 5202 PACIFIC AVE <br /> P-09A 0.75" 50 16" MEAT GRILL HOUSEKEEPING PAD TO CENTERLINE OF LINE-SET ON EQUIPMENT. STOCKTION, CA 95207 <br /> P-15 0.75" 48" CLEANING SOLVENT MIX CENTER CONTRACTOR SHALL VERIFY WITH KITCHEN PLANS AND EQUIPMENT CUTS <br /> SHEETS PRIOR TO ROUGH-IN. <br /> P-16 0.5" 63" 0.5 63" * N FLOOR MOP SINK * VERIFY DRAIN SIZE W/SINK <br /> 7. SEE SHEET K5.0 FOR ALL UNDERGROUND ROUGH-IN PLUMBING <br /> P-17 0.75" 56" 2" POTATO PEELER RUN DRAIN LINE TO FLOOR SINK. REQUIREMENTS. <br /> P-21 1" 96" FILTER SYSTEM <br /> P-22 1 12" ICE MAKER USE FILTERED WATER. <br /> P-23 0.375" 18" 0.375" 18" 1.5" 24" WALL MOUNT HAND SINK NmNmOUT <br /> P-23A 0.375" 18" 0.375" 18" 1.5" 24" WALL MOUNT HAND SINK \BURGER <br /> P-25 1 12" .5" 12" 2" THREE-COMP TURBO WASH SINK RUN DRAIN LINE TO FLOOR SINK. <br /> P-28 1 12" 0.75" ICE/BEVERAGE DISPENSER (2) EA; RUN DRAIN LINE TO FLOOR SINK. GOD BLESS AMERICA <br /> P-41 2" 450 11" GAS FRYER - GAS LINE OUT FROM WALL B.T.C. ON (5) 90MBTU FRYERS; SEE DETAIL THIS SHEET. <br /> P-49 0.75" 12" 0.75" 12" VER POTATO SINK COUNTER RUN DRAIN LINE TO FLOOR SINK. <br /> P-80 0.50" 56" HOSE BIB BOX (2) EA. <br /> PROJECT NUMBER <br /> P-80A 56" 56" HOSE BIB BOX INSTALLED IN 81A RECESS BOX - SEE 81A 190955 <br /> P-81 0.75" S.U. 4" 0.75" S.U. 4" HIGH PRESSURE WASHER UNIT LOCATED ON ROOF. <br /> P-81A 0.75" 56" HIGH PRESSURE WASHER HIGH PRESSURE WASHER REMOTE BOX. SHEET TITLE <br /> P-85 0.75" S.U. 4" 0.5" 76 SU 4" WATER HEATER (2) EA (1 FUTURE); UNITS LOCATED ON ROOF. PROVIDE 1" WATER LINE KITCHEN EQUIPMENT <br /> TO EACH W.H. FOR LOWER PRESSURE LOSS & BETTER BALANCING PLUMBING PLAN <br /> 0 <br /> P-86 0.375" 12" 0.75" ICE/BEVERAGE DISPENSER (2) EA; RUN DRAIN LINE TO FLOOR SINK. USE FILTERED WATER <br /> P-87 0.375" 12" SELF SERVE COUNTER USE FILTERED WATER; B.T.C. ON UNSPECIFIED EQUIPMENT. <br /> CD <br /> P-95 1 96" 1/2)) REVERSE OSMOSIS SYSTEM <br /> CD� <br /> P-104 1" D01f .F.A. CARBONATORS USE FILTERED WATER; *USE CARBONATOR MANIFOLD (BY PLUMBER). SEE NOTE #14. SHEET NUMBER <br /> w <br /> CD <br /> C�> o P-116 1 18" 0.5" 18" 1.5" 24" WALL MOUNT HAND SINK <br /> P-118 0.5" 16" HOT COCOA MACHINE USE FILTERED WATER. <br /> o NOTE:WATER&GAS SUPPLY LINES TO EQUIPMENT SHALL BE OVERSIZED AS SHOWN ON PLUMBING DRAWINGS IN ORDER TO ENSURE SUFFICIENT FLOW. PROVIDE REDUCERS WHERE REQUIRED TO MAKE FINAL CONNECTION TO EQUIPMENT. K4mO <br /> zZ <br />