My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
WORK PLANS
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
B
>
BENJAMIN HOLT
>
864
>
1600 - Food Program
>
PR0547158
>
WORK PLANS
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/23/2022 11:00:16 AM
Creation date
10/12/2021 4:03:05 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
1600 - Food Program
File Section
WORK PLANS
RECORD_ID
PR0547158
PE
1614
FACILITY_ID
FA0026757
FACILITY_NAME
CRUMBL COOKIE
STREET_NUMBER
864
Direction
W
STREET_NAME
BENJAMIN HOLT
STREET_TYPE
DR
City
STOCKTON
Zip
95207
CURRENT_STATUS
01
SITE_LOCATION
864 W BENJAMIN HOLT DR
P_LOCATION
01
QC Status
Approved
Scanner
SJGOV\jcastaneda
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
43
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
#10 WIRE FROM STRUCTURE UNIT HOLD DOWN TO BE REVISIONS BY <br /> FABRICATED FROM SEAL <br /> — INSTALL DRAWBANDS ON BOTH 6"W x 16 GA. STEEL, TYPICAL OF (4) <br /> 1 1/2" X 36 GA. STRAPS ENDS OF FLEX DUCT, TYPICAL NAIL STRIP WITH <br /> WITH 2-#8 SMS EACH MOUNTING FRAME <br /> SIDE OF DUCT ROOF FRAMING <br /> 4'-0" MAXIMUM SPACING <br /> BETWEEN STRAPS <br /> SECURE UNIT BASE <br /> UPBLAST EXHAUST FAN RAIL WITH (4) #10 x 1"TEK <br /> NEMA 3R DISCONNECT ----------_------------ SCREWS, TYPICAL <br /> REFER TO AC SECURE TO UNIT CURB <br /> ----- WITH (4) #10 x%2"TEK <br /> ATTACHMENT DETAIL THIS SHEET <br /> z 77 SCREWS, TYPICAL <br /> w <br /> J � <br /> w 26 ga. S/M COUNTER FLASHING ---------- <br /> MOUNTING FRAME BY <br /> MAXIMUM SAG cr UNIT MANUFACTURER. <br /> Y2" PER FOOT OF SUPPORT SPACING _ (EXTENDS ALL AROUND <br /> INSULATED FLEXIBLE DUCT GREASE CONTAINER Q RIGID INSULATOIN <br /> SUPPLIED WITH FAN 0 #10 S/M SCREW o PERIMENTER OF UNIT) <br /> 2 EACH SIDE, TYPCIAL o ROOF SHEATHING, SEE 2 <br /> NOTES: VENTED CURB EXTENSION ARCHITECTURAL DRAWINGS <br /> FOR ROOFING SPECIFICATIONS ❑ <br /> FLEXIBLE DUCT SHALL BE THERMAFLEX MODEL MK-E CONSISTING OF AN INNER CORE, INSULATION AND AN OUTER MINIMUM 3x DUCT DIA. z --------------------- U ko <br /> INSTALL WITH REGISTER � <br /> MOISTURE BARRIER. THE INNER CORE SHALL BE CONSTRUCTED OF A CHLORINATED POLYETHYLENE (CPE) Y4" LAG BOLT, 2 EACH SIDE ------------- _ <br /> BOX WHERE CONDITIONS <br /> BOUNDED TO THE COATED WIRE HELIX FOR MAXIMUM STRENGTH AND DURABILITY. AN INSULATING BLANKET — INSTALL TAPER <br /> PREVENT 3x DUXT DIA. p � <br /> WOVEN OF FIBERGLASS SHALL ENCASE THE INNER CORE AND SHALL BE SHEATHED WITH AN OUTER VAPOR WHEN REQUIRED EXHAUST DUCT- SEE PLAN FOR SIZE = U m ❑ <br /> BARRIER OF METALIZED POLYESTER FILM. THE VAPOR BARRIER SHALL BE .05 PERM PER ASTM E96, THE FLEXIBLE SEE ARCHITECTURAL DRAWINGS FOR = z m W ' <br /> DUCT SHALL BE RATED FOR A MAXIMUM WORKING VELOCITY OF 5500 FPM AND SHALL BE CERTIFIED BY THE 1 ROOF CONSTRUCTION 00 2E <br /> #7 x/2" S/M SCREWS, (4) REQUIRED #10 x%2" S/M U <br /> UNDERWRITERS LABORATORIES UNDER THEIR UL 181 STANDARDS AS CLASS 1 DUCT, AND BEAR AN SKEW, TYPICAL SIMPSON ST292 TIE STRAP, OR EQUAL — <br /> UNDERWRITERS LABORATORIES STAMP TYPICAL AT ALL (4) SIDES I <br /> SUSPENDED GRID CEILING ���__ too <br /> o <br /> FLEXIBLE DUCTS SHALL BE SUPPORTED AT 4'-0" O.C. WITH 1-1/2" WIDE, 28 GA. STEEL HANGER COLLAR ATTACHED SYSTEM, SEE ARCHITECTURAL ° <br /> � � 04x6 BLOCKING W/ U V TO THE STRUCTURE WITH AN APPROVED DUCT HANGER. COLLARS SHALL HAVE HEMMED EDGES TO PREVENT DRAWINGS FOR SPECIFICATION ° U HANGER AT EACH END <br /> CUTTING OF FLEXIBLE DUCT. INSULATION SHALL MINIMIZE SHARP RADIUS TURNS OR OFFSETS. � ROOF FRAMING V <br /> 5al %2" DIAMETER BOLT @ 6-0" O.C., W Q ❑ <br /> ALL MATERIAL EXPOSED WITHIN DUCTS OR PLENUMS SHALL HAVE A FLAME SPREAD RATING OF NOT MORE THAN LENGTH, AS REQUIRED ---------------- (2) LAYERS OF 1" GYPSUM <br /> ---------------- PROVIDE WEATHERPROOF /2" DIA. BOLT (LENGTH AS REQUIRED) [v <br /> 26 AND A SMOKE-DEVELOPED RATING OF NOT MORE THAN 50. 24" x 24" DROP-IN BOARD WITH JOINTS .. <br /> MODULE CEILING DIFFUSER TIE-IN ALL AROUND (2) PER SIDE LOCATED 8" FROM ENDS ❑ <br /> (3) PER SIDE IF GREATER THAN 4'-6" STAGGERED FOR SOUND Q <br /> FLEX DUCT TO BE MOUNTED WITH A MAXIMUM DISTANCE OF 12" FROM OVERHEAD SO NO SEISMIC BRACING IS ADDITIONAL SUPPORT, AS REQUIRED -- - - - - CANT STRIP ALL AROUND CONTROL J N X <br /> REQUIRED 26 GA. GALVANIZED S/M CLIP 3: <br /> ❑ W Q <br /> LL <br /> 1 O FLEXIBLE DUCT SUPPORT 1- /2AL1'-0" 7 AIR REGISTER 1- /2AL1" 4 UPBLAST KITCHEN EXHAUST FAN 1- /2AL1'-o" 1 HVAC UNIT CURB - REFERENCE 1- /2AL1'-0" El ❑ <br /> 0 <br /> Z2 <br /> Q <br /> Q n <br /> WOOD STRUCTURAL MEMBER <br /> W Ln <br /> 4' MAX. <br /> INSULATED PANELS j W � <br /> MAKE-UP AIR UNIT <br /> UNIT HOLD DOWNS TO BE ❑ <br /> FABRICATED FROM 6"WIDE a W ' <br /> \\ <br /> THREADED INSERT 16 GA. STEEL, TYPICAL OF (4) En <br /> WIRE ROPE 00 <br /> ❑ I Ln <br /> THREADED STUD .-. <br /> °° a) <br /> -------------------------------------------- <br /> �� \' %4" DIAMETER LAG °° SUPPLY W ❑ <br /> II TRIM EXCESS WIRE ROPE BOLTS @ 24" O.C. I N <br /> SELF LOCKING, ADJUSTABLE GRIP _ SEE ATTACHMENT DETAIL, � °°°° <br /> THIS DRAWING <br /> RIGID DUCT <br /> i o o CURB CONSTRUCTED RETURN ko <br /> REFER TO PLANS FOR OF 18 GA. GALVANIZED a <br /> STEEL, TYPICAL <br /> MOUNTING ANGLE <br /> SEE PLAN FOR DUCT SIZE °°° D <br /> m m ° <br /> a 0 <br /> WIRE ROPE El <br /> SUPPLY GRILLE <br /> sE° ARcy <br /> �ooh J. a��� <br /> J <br /> NOTES: MINIMUM 4x6 WITH <br /> SECURE TO UNIT CURB SECURE TO UNIT BASE RAIL WITH C-25449 p <br /> U-HANGER, EACH END L PROVIDE WEATHERPROOF WITH (4) #10 x%2"TEK <br /> 1. INSTALL PER MANUFACTURER'S RECOMMENDATIONS FOR LOADING (4) #10 x/2 TEK SCREWS, TYPICAL 6-30-21 <br /> 2. APPROVED MANUFACTURER IS GRIPPLE. WWW.GRIPPLE.COM i TIE-IN ALL AROUND SCREWS, TYPICAL �' RENEWAL DATE <br /> /2" DIAMETER BOLT AT 6'-0" O.C., � <br /> 3. WIRE ROPE AND THREADED STUD SHALL BE PROVIDED AS ONE ASSEMBLY LENGTH, AS REQUIRED CANT STRIP ALL AROUND ATF OF CAS 0 <br /> 8 RIGID DUCT SUPPORT 1- /2AL1'-0 " S MAKE UP AIR UNIT 1- /2AL1'-0" 2 AC UNIT ATTACHMENT - REFERENCE 1- /2AL1'-0" <br /> REFER TO ECONOMIZER REDUCE GAS LINE SIZE <br /> DESCRIPTION SCHEDULE TO UNIT SIZE AT FINALSTORM COLLAR <br /> FOR REQUIREMENTS — ELBOW(BY P.C.) <br /> WITH DRAW BAND ON TOP 4g° crumbl <br /> CONDENSATE LINE <br /> 26 GA. GALV. WITH TRAP c o o k i e s <br /> EXHAUST HOOD 1/4" MESH GISCREEN SCREEN REFER TO PLUMBING <br /> WATER ENTRAINMENT DRAWINGS FOR DETAIL INTERIOR TENANT <br /> IMPROVEMENT <br /> OUTSIDE AIR FILTER AC <br /> BRIEDERT TYPE ROOF LOCATION <br /> "B" FLUE CAP BAROMETRIC RELIEF 864 W. BENJAMIN HOLT DR. <br /> C° STOCKTON, CA <br /> N SEE MANUFACTURED 95207 <br /> ROOF COVERING, TYPICAL CURB DETAIL THIS DRAWING i A.P.N.: 09741060 <br /> SEE ARCHITECTURAL DRAWINGS 4" 6" 4" <br /> ROOF STRUCTURE, TYPICAL ii FLASHING FRANCHISE OWNER <br /> SEE ARCHTIECTURAL DRAWINGS KTK CO. <br /> ii BLOCKING 3966 GLEN ABBY CIRCLE <br /> ROOF STRUCTURE STOCKTON, CA <br /> 95219 <br /> 4" C E.A. DUCT <br /> 1" ACOUSTICAL DUCT <br /> LINING ON RETURN AND <br /> SUPPLY DUCTS. SEE REFER TO PIPE <br /> FLOOR PLANFOR SIZES, TYPICAL PENETRATION DETAIL <br /> BACKDRAFT DAMPER — HANGER WIRE OR SEE PLUMBING DRAWN <br /> `i <br /> BLOCKING AS REQUIRED DRAWINGS TAF <br /> / <br /> UCEF ECONOMIZER CAPACITY SCHEDULE CHECKED <br /> TAPPED FLEXIBLE SLW <br /> i CAPACITIES <br /> i <br /> GAS TO PENETRATE THRU <br /> i <br /> 1 x/$ CONNECTION RING CLAMPS AND i UNIT SIZE PERCENTAGE RELIEF RELIEF DATE <br /> iRELIEF CFM SIZE <br /> KNOCK-OUT WITHIN CURB 5/25/2 <br /> 21SUPP RT BRACKETS <br /> SECURE WITH%4" DIA.x 2" 1"AIR SPACE 3 4 TONS 100% ELIMINATING ROOF <br /> LAG SCREWS o (BAROMETRIC) 1700 9"x30" PENETRATION SCALE <br /> 5 TONS 85% (BAROMETRIC) 1700 9"x30" AS SHOWN <br /> 6 TONS 70% (BAROMETRIC) 1700 9"x30" JOB NO. <br /> 21-136 <br /> DOUBLE WALL FLUE <br /> FINISHED CEILING GRILLE 7.5 TONS TO BE SUPPLIED WITH POWER EXHAUST SHEET <br /> & UP CAPABLE OF 100% ECONO. OPERATION <br /> i <br /> Mm3mO <br /> 9 WATER HEATER FLUE 1- /SCALE: <br /> AL1'-o" 6 CEILING MOUNTED EXHAUST FAN 1- /SCALE- <br /> AL1'-o" 3 AC UNIT CONNECTIONS - REFERENCE 1- /2AL1'-0" <br /> OF SHEETS <br />