Home
Browse
Search
WORK PLANS
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
Y
>
YOSEMITE
>
750
>
1600 - Food Program
>
PR0161533
>
WORK PLANS
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/20/2021 7:17:05 PM
Creation date
10/15/2021 3:39:59 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
1600 - Food Program
File Section
WORK PLANS
RECORD_ID
PR0161533
PE
1632
FACILITY_ID
FA0001342
FACILITY_NAME
MUSD-LINCOLN SCHOOL
STREET_NUMBER
750
Direction
E
STREET_NAME
YOSEMITE
STREET_TYPE
AVE
City
MANTECA
Zip
95336
APN
22118001
CURRENT_STATUS
01
SITE_LOCATION
750 E YOSEMITE AVE
P_LOCATION
04
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\jcastaneda
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
2850
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
PLUMBING SYSTEM ACCESSORIES <br />Section 15410 <br />15-1207 <br />16. Provide additional tag at each valve noted below. Tag shall be black plastic with <br />white lettering, 3 -ply, 125 mil thick, Minimum 3" square. <br />VALVE FUNCTION <br />LOCATION <br />TAG TEXT <br />Main Domestic Water <br />Main water supply <br />"MAIN DOMESTIC <br />shut-off <br />entrance to <br />WATER SHUT-OFF" <br />building. <br />Domestic cold water <br />Riser shut-off valve <br />"RISER ## CW SHUT - <br />risers in multi -floor <br />OFF" with number of <br />building <br />riser. <br />Restroom shut-off <br />In -wall at <br />"Restroom Isolation <br />valves <br />Restrooms <br />Valve, Serves Rooms <br />and <br />Main Natural Gas <br />Immediately <br />MAIN NATURAL <br />Shut-off <br />downstream of gas <br />GAS SUT-OFF <br />meter <br />Building Natural Gas <br />At Entrance to each <br />"BUILDING _ <br />Shut-off <br />building <br />NATURAL GAS SHUT <br />OFF" <br />3.02 PIPE ESCUTCHEONS: <br />A. Install pipe escutcheons on each pipe penetration through floors, walls, partitions, and <br />ceilings where penetration is exposed to view and on exterior of building. <br />B. Tighten escutcheon to pipe or insulation so escutcheon covers penetration hole and is flush <br />with adjoining surface. <br />3.03 SLEEVES: <br />A. Secure sleeves to metal or wood forms in such a manner that they will not become <br />displaced during pouring of concrete. Fill sleeves on deck with sand. <br />B. After forms have been removed from concrete, the sleeves shall be removed from the <br />openings. <br />C. Core drill properly sized holes in the concrete to replace metal sleeves that are crushed or <br />knocked out of position during pouring of concrete. <br />D. Provide piping passing through concrete fire walls with sleeves of standard black steel pipe <br />nominally one size larger than pipe enclosed, but in the case of insulated pipe, large enough <br />for insulation to pass through. Caulk space between pipe and sleeve with fire -rated wicking, <br />and provide metal retainer plates at both sides of the wall. <br />E. Sleeve Seals: Install in accordance with the following: <br />1. Lead and Oakum: Fill and pack annular space between sleeve opening and pipe <br />with oakum; caulk with lead on both sides. <br />2. Mechanical Sleeve Seals: Loosely assemble rubber links around pipe with bolts and <br />pressure plates located under each bolt head and nut. Push into sleeve opening and <br />center. Tighten bolts until links have expanded to form watertight seal. <br />12 <br />