My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
WORK PLANS
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
Y
>
YOSEMITE
>
750
>
1600 - Food Program
>
PR0161533
>
WORK PLANS
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/20/2021 7:17:05 PM
Creation date
10/15/2021 3:39:59 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
1600 - Food Program
File Section
WORK PLANS
RECORD_ID
PR0161533
PE
1632
FACILITY_ID
FA0001342
FACILITY_NAME
MUSD-LINCOLN SCHOOL
STREET_NUMBER
750
Direction
E
STREET_NAME
YOSEMITE
STREET_TYPE
AVE
City
MANTECA
Zip
95336
APN
22118001
CURRENT_STATUS
01
SITE_LOCATION
750 E YOSEMITE AVE
P_LOCATION
04
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\jcastaneda
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
2850
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
PACKAGED AIR CONDITIONING <br />UNITS <br />Section 15855 <br />15-1207 <br />5. The compressor shall be resiliently mounted and have built- in, three -mode crankshaft <br />lubrication; crankcase heater; discharge temperature limiter; and current- and temperature - <br />sensing motor overloads. <br />6. The cooling system shall be protected by high and low pressure switches, filter dryer, oil <br />failure switch, and a five-minute, compressor, timed off cycle controller (anti- recycle timer), <br />and evaporator coil frostat that shall disable cooling when temperatures on the evaporator <br />coil reach 10 degrees or below. Mechanical cooling will start again when temperatures on <br />the evaporator coil rise to 50 degrees or above. <br />B. Cabinet: <br />1. Galvanized steel with a baked -on outdoor enamel paint finish. <br />2. Cabinet panels where conditioned air is handled shall be fully insulated. <br />3. Lifting lugs shall be provided for rigging. <br />4. Unit shall have a raised 1 1/8 inch lip around the supply and return openings. <br />C. Single -side Service Access: <br />1. All components, wiring, and inspection areas shall be completely accessible via one side of <br />the unit through hinged access panels. <br />2. Hinged access panels shall provide access to filter section, fan section, compressor section, <br />heat section, and controls. <br />a. No tools shall be required for the panels. <br />D. <br />Supply Air Blowers: <br />1. <br />Centrifugal blowers shall have belt drive motors unless noted otherwise on the Drawings. <br />2. <br />The entire assembly shall be resilient rubber mounted. <br />3. <br />Blower wheel assembly shall be statically and dynamically balanced. <br />4. <br />Supply blower motors shall be thermally protected and meet the US EPACT 1992 Code. <br />E. <br />Supply <br />Blower Variable Frequency Drive (VFD): <br />1. <br />Provide variable air volume supply air temperature control with variable frequency drive <br />without bypass where noted on drawings. <br />2. <br />Provide all necessary controls to modulate the VFD in cooling mode to maintain a <br />discharge air temperature setpoint. <br />F. <br />Condenser Fans: <br />1. <br />Propeller -type condenser fans shall discharge vertically. <br />2. <br />Fan motor shall be totally enclosed with sleeve bearings, permanently lubricated, thermally <br />protected and equipped with rain shield. <br />3. <br />Fan shall be protected by a steel guard. <br />G. <br />Condenser Coil Guard: <br />1. <br />Factory installed tool -less panel guard shall be manufactured from minimum 20 gauge steel <br />with G90 -U corrosion protection. <br />2. <br />The panel shall be powder coated to match the unit color. <br />3. <br />Guard open area shall be between fifty percent and sixty percent. <br />H. <br />Evaporator <br />Coil Drainpan: <br />1. <br />Drainpan shall be constructed of stainless steel and shall be double -sloped. <br />2. <br />Unit shall allow for drain on either side and shall have reversible drainpan provided. <br />Cl <br />
The URL can be used to link to this page
Your browser does not support the video tag.