My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
WORK PLANS
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
Y
>
YOSEMITE
>
750
>
1600 - Food Program
>
PR0161533
>
WORK PLANS
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/20/2021 7:17:05 PM
Creation date
10/15/2021 3:39:59 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
1600 - Food Program
File Section
WORK PLANS
RECORD_ID
PR0161533
PE
1632
FACILITY_ID
FA0001342
FACILITY_NAME
MUSD-LINCOLN SCHOOL
STREET_NUMBER
750
Direction
E
STREET_NAME
YOSEMITE
STREET_TYPE
AVE
City
MANTECA
Zip
95336
APN
22118001
CURRENT_STATUS
01
SITE_LOCATION
750 E YOSEMITE AVE
P_LOCATION
04
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\jcastaneda
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
2850
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
AIR & WATER SYSTEM BALANCING <br />AND ACCOUSTICAL TESTING <br />Section 15990 <br />15-1207 <br />(6) Approximate suction static pressure in w.g. <br />(7) Approximate discharge static pressure in w.g. <br />(8) Fan rpm <br />2. Rated and Actual Motor Data: <br />a. Horsepower / Break -horsepower <br />b. Phase <br />C. Voltage. <br />d. Amperage. <br />3. Duct Velocity Traverse Data: <br />a. Fan or unit number <br />b. Design and actual CFM <br />C. Duct division signs and area. <br />d. Design and actual average velocity <br />e. Duct static pressure average velocity <br />f. Traverse location <br />g. Traverse measurements in fpm (show grid pattern) <br />4. Individual Outlet and Inlet Data: <br />a. Identify each outlet for location, area, and fan or unit system <br />b. Outlet or inlet manufacturer and type <br />C. Outlet or inlet size, effective area or Ak factor <br />d. Design and actual velocity in feet per minute (FPM) <br />e. Design and actual CFM <br />5. Other information required to establish completely balanced systems. <br />3.02 BALANCE REQUIREMENTS: <br />A. Make allowance for air filter resistance at time of tests. Balance main air supplies at design <br />air quantities and at an air resistance across filter bank midway between design <br />specifications for clean and dirty filters. <br />B. Balance work within the following tolerances: <br />1. Supply, Return, Exhaust inlets/outlets: balance within -5% / +10% of design CFM. <br />2. Outside Air Inlets: balance within -0% / +10% of design CFM. <br />C. Rooms with positive or negative pressure requirements to maintain a minimum of 15% <br />differential pressure regardless of the above tolerances. <br />D. Provide a room or building pressure test for each system. Maximum building pressure shall <br />not exceed 0.03" inches of pressure. <br />E. HVAC systems shall be balanced at normal "minimum outside air" condition. Where such <br />systems are required to deliver 100 -percent return air or a variable amount of outside air, as <br />indicated in specifications for automatic temperature control sequences, total CFM test shall <br />be repeated for 100 -percent return air and maximum outside air shall agree with conditions <br />found under maximum outside air operation before system is considered to be in balance. <br />Adjustments of proper dampers shall be made to achieve balance and marked so that <br />4 <br />
The URL can be used to link to this page
Your browser does not support the video tag.