My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
WORK PLANS
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
Y
>
YOSEMITE
>
750
>
1600 - Food Program
>
PR0161533
>
WORK PLANS
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/20/2021 7:17:05 PM
Creation date
10/15/2021 3:39:59 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
1600 - Food Program
File Section
WORK PLANS
RECORD_ID
PR0161533
PE
1632
FACILITY_ID
FA0001342
FACILITY_NAME
MUSD-LINCOLN SCHOOL
STREET_NUMBER
750
Direction
E
STREET_NAME
YOSEMITE
STREET_TYPE
AVE
City
MANTECA
Zip
95336
APN
22118001
CURRENT_STATUS
01
SITE_LOCATION
750 E YOSEMITE AVE
P_LOCATION
04
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\jcastaneda
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
2850
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
HANGERS AND SUPPORTS <br />FOR ELECTRICAL SYSTEMS <br />Section 16012 <br />15-1207 <br />A. Penetrations: Provide through -penetration firestop systems that are installed to <br />resist the spread of fire, passage of smoke and other hot gases according to <br />requirements indicated, to restore the original fire -resistance rating of assembly <br />penetrated. <br />1. Install complete through penetration firestop systems that have been <br />tested and are listed by recognized testing agencies per ASTM E 814 or <br />UL 1479 fire tests in a configuration that is representative of site <br />conditions. <br />2. F -Rated Systems: Install through -penetration firestop systems with F - <br />ratings indicated, as determined per ASTM E 814 or UL 1479, but not <br />less than the fire resistance rating of the assembly being penetrated. <br />3. T -Rated Systems: Install through -penetration firestop systems with T- <br />racings indicated, as well as F -ratings, as determined per ASTM E 814 or <br />UL 1479, where required by the Building Code. <br />1.6 SUBMITTALS <br />A. Shop Drawings: Indicate system layout with location and detail of trapeze <br />hangers. <br />B. Product Data: <br />1. Hangers and Supports: Submit manufacturers catalog data including load <br />capacity. <br />2. Firestopping: Submit data on product characteristics, performance and <br />limitation criteria. <br />C. Firestopping Schedule: Submit schedule of opening locations and sizes, <br />penetrating items, and required listed design numbers to seal openings to <br />maintain fire resistance rating of adjacent assembly. <br />D. Design Data: Indicate load carrying capacity of trapeze hangers and hangers and <br />supports. <br />E. Manufacturer's Installation Instructions: <br />1. Hangers and Supports: Submit special procedures and assembly of <br />components. <br />2. Firestopping: Submit preparation and installation instructions. <br />F. Manufacturer's Certificate: Certify products meet or exceed specified <br />requirements. <br />G. Engineering Judgements: For conditions not covered by UL or WH listed <br />designs, submit judgements by licensed professional engineer suitable for <br />presentation to authority having jurisdiction for acceptance as meeting code fire <br />protection requirements. <br />1.7 SEISMIC DETAILS AND CALCULATIONS <br />2 <br />