My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
WORK PLANS
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
Y
>
YOSEMITE
>
750
>
1600 - Food Program
>
PR0161533
>
WORK PLANS
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/20/2021 7:17:05 PM
Creation date
10/15/2021 3:39:59 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
1600 - Food Program
File Section
WORK PLANS
RECORD_ID
PR0161533
PE
1632
FACILITY_ID
FA0001342
FACILITY_NAME
MUSD-LINCOLN SCHOOL
STREET_NUMBER
750
Direction
E
STREET_NAME
YOSEMITE
STREET_TYPE
AVE
City
MANTECA
Zip
95336
APN
22118001
CURRENT_STATUS
01
SITE_LOCATION
750 E YOSEMITE AVE
P_LOCATION
04
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\jcastaneda
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
2850
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Geotechnical Engineering and Geological Hazard Study <br />Lincoln Elementary School Modemization Project <br />Manteca, California <br />Page 1? <br />7.3 UNDERGROUND UTILITY TRENCHES <br />Unless concrete bedding is required around utilities, pipe bedding should consist of sand with a sand <br />equivalent of at least 30 or the pipe manufacturer's requirements, whichever is more restrictive. The pipe <br />bedding should extend from 6 inches below the invert of the pipe to 1 foot above pipe the crown of the <br />pipe. The pipe bedding material should be compacted to a minimum of 90 percent relative compaction or <br />the manufacturer's recommendations if more stringent. <br />Trench backfill above the pipe bedding zone should be placed in the same manner as required in Section <br />7.2.5, Engineered Fill Placement. On-site fill soils and "non-organic" native soils may be used as backfill <br />in trenches above the pipe bedding. Utility trench backfill should be placed in layers not exceeding a <br />loose lift thickness of 8 inches, uniformly moisture conditioned, and compacted to a minimum of <br />90 percent relative compaction. <br />Compaction criteria for trench backfill above the bedding zone may be decreased to 85 percent relative <br />compaction in landscape areas at least 5 feet beyond structural improvements, except in areas overlain by <br />pavements, sidewalks, or other hardscapes. In landscape areas overlain by pavements, sidewalks, or other <br />hardscapes, we recommend that the trench backfill be compacted to a minimum of 90 percent relative <br />compaction to within 1 foot of the finished subgrade surface. The upper 1 foot should be compacted to <br />95 percent relative compaction in areas to receive AC pavement. <br />7.4 SURFACE DRAINAGE CONTROL <br />Surface drainage should be planned to prevent ponding and to enable water to drain away from building <br />foundations, slabs, and edges of pavements toward suitable collection of discharge facilities. A positive <br />surface drainage of at least five percent should be provided within 10 feet of all building foundations. <br />Elsewhere, positive surface drainage of at least two percent is recommended to allow for rapid removal of <br />surface water. Pavements should also be designed with minimum gradients of about 2 percent in their <br />principal direction of drainage, unless drainage reaches are short. Roof drainage systems should be <br />planned to direct rainwater away from building foundations. A detailed drainage plan is outside the scope <br />of this report but should be included in the preparation of the grading plans for the project. <br />8.0 FOUNDATION RECOMMENDATIONS <br />8.1 GENERAL FOUNDATION RECOMMENDATIONS <br />All foundation improvements should be designed and constructed in accordance with the 2013 California <br />Building Code, Title 24, Chapter 17A (Structural Tests and Special Inspections), Chapter 18A (Soils and <br />Foundations), and all other sections applicable to the proposed structural improvements. Note that all <br />stated preliminary bearing pressures in Section 8.0 are net values, and the weight of concrete in the <br />portion of the foundations that extends below grade can be neglected in proportioning the foundations. <br />Further evaluation of the subsurface may be warranted based on any other specific foundation designs not <br />considered in this report. <br />Site characteristics considered in selection of appropriate foundation system include the presence of <br />(1) potentially liquefiable deposits under much of the Site. The use of engineered fill beneath shallow <br />foundations systems, as described in Section 6.2.2, is recommended to improve the ability of the <br />foundations and floor slabs to resist the adverse effects of seismically -induced ground deformation. <br />Piping and utility connections should be designed to accommodate the estimated maximum foundation <br />settlements. <br />13 <br />
The URL can be used to link to this page
Your browser does not support the video tag.