ASBESTOS ABATEMENT -- <br />ROOFING <br />Section 02082 <br />15-1207 <br />B. Appropriately labeled, closed, impermeable drum containers. <br />C. Bilingual labels (English and Spanish) on containment glove bags, waste packages, <br />contaminated material packages and other containers shall be in accordance with EPA or <br />OSHA standards. <br />2.02 WARNING LABELS AND SIGNS <br />A. As required by 29 CFR 1926.58 and 29 CFR 1910.145. <br />2.03 PERSONAL PROTECTIVE EQUIPMENT <br />A. Personal Protective Equipment shall comply with the requirements of 29 CFR 1910, Subpart <br />I. <br />B. Work clothes shall consist of fire retardant, disposable, full-body coveralls, head covers, <br />boots, rubber gloves and sneakers or equivalent in accordance with 29 CFA 1926.58, and <br />ANSI Z41. Sleeves at wrists and cuffs at ankles shall be secure. <br />C. Eye protection and hard hats shall be available as required by applicable safety regulations <br />and shall conform to ANSI 87.1 and 89.1. <br />D. Provide authorized visitors with suitable protective clothing, headgear, eye protection and <br />footwear whenever they are required to enter Work area. <br />2.04 RESPIRATORS <br />A. Provide all workers, foremen, superintendents, authorized visitors and inspectors personally <br />issued and marked respiratory equipment jointly approved by NIOSH/MSHA. When <br />respirators with disposable filters are employed, provide sufficient filters for replacement as <br />recommended by manufacturers or this Specification. Selection of respirators shall be made <br />according to the guidance of 29 CFR 1910, Subpart 1; ANSI Z88.2; CGAI G7.1; EPA 560 <br />OPTS -86-.001. <br />B. When positive pressure supplied air Type "C" equipped with full face piece respirators are <br />employed, the Air Supply System shall provide Grade "D" breathing air in accordance with <br />OSHA 29 CFR 1910, Subpart I and ANSI Z88.2 and CGAI G7.1. <br />C. The Compressed Air System for Type "C" Respirators shall be high pressure (nominal 100 <br />psi), with a compressor capacity to satisfy the respirator manufacturer's recommendations. <br />The receiver shall have sufficient capacity to allow a 15 minute escape time for the respirator <br />wearers in the event of compressor failure or malfunction. Type C supplied air respirators <br />with HEPA filter disconnect may be used as an alternate to the 15 minute escape time <br />required with event of compressor failure for Type C respirators. The Compressed Air <br />System shall have compressor failure alarm, high temperature alarm, carbon monoxide <br />alarm, and suitable in-line air purifying sorbent beds and filters to assure Grade "D" breathing <br />air. <br />D. The minimum respiratory protection required for this project is as follows: <br />Use half face mask air purifying respirators approved for asbestos in case the removal <br />