My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
WORK PLANS
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
Y
>
YOSEMITE
>
750
>
1600 - Food Program
>
PR0161533
>
WORK PLANS
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/20/2021 7:17:05 PM
Creation date
10/15/2021 3:39:59 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
1600 - Food Program
File Section
WORK PLANS
RECORD_ID
PR0161533
PE
1632
FACILITY_ID
FA0001342
FACILITY_NAME
MUSD-LINCOLN SCHOOL
STREET_NUMBER
750
Direction
E
STREET_NAME
YOSEMITE
STREET_TYPE
AVE
City
MANTECA
Zip
95336
APN
22118001
CURRENT_STATUS
01
SITE_LOCATION
750 E YOSEMITE AVE
P_LOCATION
04
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\jcastaneda
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
2850
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
EARTHWORK <br />Section 02200 <br />15-1207 <br />and the like shall be removed from site. Excavations resulting from these removal activities <br />shall be cleaned of all loose materials, dish shaped, and widened as necessary to permit <br />access for compaction equipment. Areas exposed by any required over -excavation should <br />be scarified to a depth of 6", moisture -conditioned to near optimum moisture content, and <br />recompacted to at least 95% of the maximum dry density. <br />3.04 TESTING AND OBSERVATION <br />A. All grading and earthwork operations shall be observed by the Geotechnical Engineer or his <br />representative, serving as the representative of the Owner. <br />B. Field compaction tests shall be made by the Geotechnical Engineer or his representative. If <br />moisture content and/or compaction are not satisfactory, Contractor will be required to <br />change equipment or procedure or both, as required to obtain specified moisture or <br />compaction. Notify Geotechnical Engineer at least 48 hours in advance of any filling <br />operation. <br />C. Earthwork shall not be performed without the notification or approval of the Geotechnical <br />Engineer or his representative. The Contractor shall notify the Geotechnical Engineer at <br />least two (2) working days prior to commencement of any aspect of the site earthwork. <br />D. If the Contractor should fail to meet the compaction or design requirements embodied in this <br />document and on the applicable plans, he shall make the necessary readjustments until all <br />work is deemed satisfactory, as determined by the Geotechnical Engineer or <br />Architect/Engineer. <br />E. After each rain event Geotechnical Engineer shall test fill material for optimum moisture. Do <br />not place any fill material until desired moisture is achieved. <br />3.05 CLEARING AND GRUBBING <br />A. Prior to grading, remove all debris off-site. Remove trees and brush including the root <br />systems. Holes resulting from tree and brush removal should be prepared and backfilled in <br />accordance with paragraphs 3.07, 3.08, 3.09, and 3.10. This may require deepening and/or <br />widening the holes to adequately remove disturbed soil and provide room for compaction <br />equipment. Strip the surface of all organics. <br />3.06 CUTTING <br />A. Building pads that are located within a cut/fill transition area will have to be overexcavated to <br />provide a semi -uniform fill beneath the building pad. The portions of building pads located in <br />cut areas shall be overexcavated to provide no more than 1 foot difference in fill placed in <br />the same building pad. <br />B. Do all cutting necessary to bring finish grade to elevations shown on Drawings. <br />C. When excavation through roots is necessary, cut roots by hand. <br />D. Carefully excavate around existing utilities to avoid unnecessary damage. The contractor <br />6t <br />
The URL can be used to link to this page
Your browser does not support the video tag.