WORK PLANS
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
Y
>
YOSEMITE
>
750
>
1600 - Food Program
>
PR0161533
>
WORK PLANS
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/20/2021 7:17:05 PM
Creation date
10/15/2021 3:39:59 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
1600 - Food Program
File Section
WORK PLANS
RECORD_ID
PR0161533
PE
1632
FACILITY_ID
FA0001342
FACILITY_NAME
MUSD-LINCOLN SCHOOL
STREET_NUMBER
750
Direction
E
STREET_NAME
YOSEMITE
STREET_TYPE
AVE
City
MANTECA
Zip
95336
APN
22118001
CURRENT_STATUS
01
SITE_LOCATION
750 E YOSEMITE AVE
P_LOCATION
04
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\jcastaneda
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
2850
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
STRUCTURAL STEEL <br />Section 05100 <br />15-1207 <br />work piece. The test studs shall be subjected to a 90 -degree bend test by striking <br />them with a heavy hammer. After the above test, the weld section shall not <br />exhibit any tearing out or cracking. <br />B. Types of Welds (unless otherwise noted): <br />1. Make all fillet welds 3/16 inch minimum. <br />2. Make all butt welds complete penetration welds, see Article 3.03 A. <br />3. Welds not required to be complete penetration welds are specifically noted on the <br />Drawings. <br />C. Grinding: Grind smooth the following structural steel and connections; <br />1. Exposed cut ends of structural and fabricated shapes. <br />2. All welds exposed to view. <br />3. Mitered and fit -up corners and intersections. <br />D. Backing Bars: Required for all complete penetration welds <br />3.04 ERECTION <br />A. General: Erect all structural steel in strict accordance with the Drawings, and all pertinent <br />regulations, unless otherwise noted. <br />B. Erection Tolerances: <br />General: Per AISC Code of Standard Practice: <br />a. Maximum Variation from Plumb: 1/4 inch per story, non -cumulative, <br />b. Maximum Offset from True Alignment: 1/4 inch. <br />2. Acceptance of Position and Alignment: Prior to placing or applying any other materials, <br />the Contractor is responsible for determining that the location of the structural steel is <br />acceptable for plumbness, level and alignment within tolerances. The erector is given <br />timely notice of acceptance by the Contractor or a listing of specific items to be <br />corrected in order to obtain acceptance. Such notice is rendered immediately upon <br />completion of work and prior to start of work by other trades that may be supported, <br />attached to the structural steelwork. <br />C Templates: Provide bolt setting templates for all anchor bolts. Provide instructions for the <br />setting of anchors and bearing plates, verify these items are set correctly as work <br />progresses. <br />D. Column base plates: Set level to correct elevations, support temporarily on steel wedges, <br />shims, or leveling nuts where shown, until the supported members are plumbed and grouted. <br />1. Grout solid the full bearing area under base plates prior to installation of floor and/or <br />roof decks. See Section 03300 - Cast -In -Place Concrete. <br />2. Comply with manufacturer's instructions for non -shrink grout. Trowel grouted surfaces <br />smooth, splaying neatly to 45 degrees. <br />11 <br />