Laserfiche WebLink
METAL DECK <br />Section 05300 <br />15-1207 <br />PART 1 - GENERAL <br />1.01 INCLUSION OF OTHER CONTRACT DOCUMENTS <br />A. The General Conditions, Supplementary Conditions and Division 1 are fully applicable to this <br />Section, as if repeated herein. <br />1.02 RELATED WORK SPECIFIED ELSEWHERE <br />A. Section 03300, Cast -In -Place Concrete. <br />B. Section 05100, Structural Steel. <br />1.03 QUALITY ASSURANCE <br />A. Use only new materials and products, unless existing materials or products are specifically <br />shown otherwise on the Drawings to be salvaged and re -used. <br />B. Use materials and products of one manufacturer whenever possible. <br />C. All materials, components, assemblies, workmanship and installation are to be observed by <br />the Owner's Project Inspector. Work not so inspected is subject to uncovering and <br />replacement. <br />D. Certification: Manufacturer's certification of compliance with the specification. <br />E. Underwriters' Label: Provide metal floor deck units listed in Underwriters' Laboratories "Fire <br />Resistance Director", with each deck unit bearing the UL label and marking for specific <br />system detailed. <br />F. Sheet Steel Welding: <br />1. General: All welding shall be in compliance with Section 05100 and applicable <br />provisions of 2013 CBC Chapter 22A. <br />2. Welders: Qualified for each light gauge welding process to be used in fabrication and <br />AWS certified. <br />1.04 SUBMITTALS <br />A. Refer to Section 01300. <br />B. Submit executed Guarantee of Contractor/Subcontractor per Article 1.05. <br />C. Product data including manufacturer's specifications, physical properties, design load tables <br />and installation instructions for each type of decking and accessories. <br />Provide ICC test reports for mechanical fasteners used in lieu of welding for fastening <br />deck to supporting structures in accordance with stud base qualification requirements <br />of AWS Code Appendix IX. <br />