Laserfiche WebLink
METAL DECK <br />Section 05300 <br />15-1207 <br />D. Shop drawings showing layout and types of deck units, anchorage details, welding <br />requirements and conditions requiring closure strips, required number and location of shear <br />connectors on each member, supplementary framing, cut openings, special jointing, and <br />other accessories. Submit shop drawings before the start of fabrication. All details must <br />reference detail callouts on the construction documents. Shop drawing submittals that do not <br />meet these requirements will be returned for correction without review. <br />E. Obtain reviewed structural steel shop drawings and verify all conditions before preparing <br />shop drawings for metal decking; show all members required for support of metal decking on <br />shop drawings for metal decking. <br />1.05 GUARANTEE <br />A. Refer to General Conditions and Section 01300. <br />B. Submit fully executed Guarantee with submittal package required by Article 1.04. <br />1.06 REFERENCES AND STANDARDS <br />A. 2013 California Building Code (CBC) as adopted by the Division of the State Architect (DSA). <br />B. American Iron and Steel Institute (AISI) "North American Specification for the Design of Cold - <br />Formed Steel Structural Members. <br />C. ASTM A36 — Structural Steel. <br />D. ASTM A653 — Steel Sheet, zinc -coated, galvanized, by the hot -dip process, structural quality. <br />E. American Welding Society (AWS), D1.3 "Structural Welding Code - Sheet Steel." <br />F. AWS D1.1 - Structural Welding Code, Steel. <br />G. Steel Deck Institute (SDI) Design Manual for Composite Decks, Form Decks and Roof Decks <br />"Publication 31 ". <br />1.07 DELIVERY, STORAGE AND HANDLING <br />A. Deliver undamaged products to job in manufacturer's sealed containers and/or original <br />bundles with tags and labels intact. <br />B. Transport, store and handle in strict accord with the manufacturer's written <br />recommendations. <br />C. Make delivery to job when notified by Contractor verifying that the job is ready to receive the <br />work of this Section and that arrangements have been made to properly store, handle and <br />protect such materials and work. <br />D. Sheets shall be protected from elements in transit. When stored at site, they shall be raised <br />off ground and be provided with weatherproof covering. Architect reserves right to reject any <br />material that has become damaged because of improper storage. <br />E. Cut plastic wrap to encourage ventilation. <br />K <br />