Laserfiche WebLink
PAINTING <br />Section 09900 <br />15-1207 <br />of painting or finishing. <br />B. Exterior: Do not apply exterior paint when air or surface temperature is under 50 degrees F or <br />when air or surface temperature will be below 50 degrees F for 48 hours after painting. Do not <br />apply immediately following snow, rain, dew or during foggy weather. Do not apply when <br />temperature is over 85 degrees F except in protected or shaded areas. In general, controlling <br />temperature and weather conditions shall be as recommended by paint manufacturer. <br />C. Interior: Do not apply interior paint when air or surface temperature is below 50 degrees F, <br />unless temperature is maintained constantly. Do not apply when ventilation is inadequate to <br />maintain humidity lower than dew point of coldest wall. <br />D. Use moisture meter for determining proper moisture levels of surfaces for painting. <br />E. Report to Architect in writing upon discovery of any prime coat painting in other Section(s) of <br />Specifications that would prevent proper application of specified finish. <br />F. Furnish, erect and remove scaffolding and planks required for work under this Section. <br />Conform to state and local codes, rules and regulations. <br />1.10 WORK NOT TO BE PAINTED (Unless specifically shown otherwise) <br />A. Exposed exterior concrete and all concrete slab surfaces, except as noted on schedules. See <br />specification Section 07180 for Water Repellents & Anti -Graffiti Coatings. <br />B. Unfinished masonry, except where noted. See specification Section 07180 for Water <br />Repellents & Anti -Graffiti Coatings. <br />C. Suspended acoustical ceilings and acoustical tile, except as noted. <br />D. Pre -finished casework. <br />E. Finish hardware (except prime coated). <br />F. Normally non -painted items as follows: Glass, ceramic tile, membrane roofing, safety nosings, <br />resilient floor covering and base, carpet, pre -finished paneling, plastic laminate, porcelain <br />enamel, vinyl wallcovering (except where noted). <br />G. Aluminum doors, windows, frames and railings. <br />H. Metal or plastic toilet partitions and other factory finished items. <br />Items of chromium, copper, nickel, brass, bronze or stainless steel. <br />Surfaces in concealed areas such as furred spaces. <br />K. Existing rooms or areas not affected by work of this project, unless specifically noted <br />otherwise. <br />L. Tops of gravel stop flanges (including priming) where roofing material will be adhered to. <br />M. Wall areas concealed by cases, counters, cabinets, chalkboards, tackboards (prime coat only <br />4 <br />