Laserfiche WebLink
MECHANICAL GENERAL CONDITIONS <br />Section 15010 <br />15-1207 <br />required. Nonconforming Mechanical work installed within designated coordination <br />areas is subject to removal and replacement by the installing contractor at no <br />additional cost to Owner. <br />3. Provide sections for congested areas. <br />4. Identify typical areas, start preparation of coordination drawings for such areas first. <br />D. Where required for coordination purposes, Contractor to modify duct shape to an equivalent <br />flattened size at no additional cost to the owner. Contractor to limit duct aspect ratio to 3:1 <br />unless provided special written permission by the Architect. <br />E. Coordination drawings shall be signed and dated by individual trade contractors. By act of <br />signature and submittal of singular combined coordination drawing, each trade contractor <br />acknowledges their coordinated portion of the work with all other mechanical, electrical, <br />telecom, architectural, and structural work contractors. <br />F. After completion of coordination shop drawings signed by individual trade contractors. <br />Submit copies to the architect for review. Once approved, provide copy at the job site for <br />reference. No work shall be performed without the complete coordination shop drawings. <br />G. No request for information regarding the routing of pipes, ductwork and placement of <br />equipment will be reviewed and responded to without a completed shop drawings. <br />1.11 SITE CONDITIONS: <br />A. Information of the drawings relative to existing conditions is approximate only. Deviations <br />found necessary during progress of construction to conform to actual conditions as <br />approved by the Architect shall be made without additional cost to the Owner. The <br />Contractor shall be held responsible for any damage caused to existing services. Promptly <br />notify the Architect if services are found which are not shown on the Drawings. <br />PART 2 - PRODUCTS <br />2.01 GENERAL: <br />A. Mention herein or on Drawings requires that this Contractor provide each item listed of <br />quality noted or equal. Refer to subsequence division 15000 specification sections for <br />specific equipment and system materials and accessories. <br />B. All material shall be new, full weight, standard in all respects, and in first- class condition. <br />C. Provide materials of the same brand or manufacture throughout for each class of material or <br />equipment wherever possible. <br />D. The grade or quality of materials desired is indicated by the trade names or catalog numbers <br />stated herein. <br />E. Dimensions, sizes, and capacities shown are a minimum and shall not be changed without <br />permission of the Architect. <br />N <br />