Laserfiche WebLink
HVAC EQUIPMENT SCHEDULE <br /> I\ CO <br /> Mark Electrical Data AMP DISCONNECT FUSE Circuit Number BRANCH CIRCUIT p c0 <br /> RTU1 200 V/3-6768 VA 18.8 30/3 30 B2-37,39,41 3/4"C-3#10+1#10 GND N O <br /> RTU2 200 V/3-6768 VA 18.8 30/3 30 P-38,40,42 3/4"C-3#10+1#10 GND O d') OC) <br /> RTU3 200 V/3-6768 VA 18.8 30/3 30 B2-38,40,42 3/4"C-3#10+1#10 GND <br /> RTU4 200 V/3-6768 VA 18.8 30/3 30 P-37,39,41 3/4"C-3#10+1#10 GND <br /> RTU5 200 V/3-6768 VA 18.8 30/3 30 HV-7,9,11 3/4"C-3#10+1#10 GND - <br /> RTU6 200 V/3-6768 VA 18.8 30/3 30 HV-1,3,5 3/4"C-3#10+1#10 GND M O N O <br /> KHR 200 V/3-3672 VA 10.2 30/3 20 B2-31,33,35 3/4"C-3#10+1#10 GND _�) c� U <br /> KHF2 200 V/3-3672 VA 10.2 30/3 20 HV-13,15,17 3/4"C-3#10+1#10 GNDN p <br /> KHF3 115 V/1-696 VA 5.8 MANUAL - HV-21 1/2"C-2#12+1#12 GNDU (� ILL. 1 <br /> MOTOR v <br /> DISCONNECT C) j M <br /> KHF4 115 V/1-696 VA 5.8 MANUAL - B2-36 1/2"C-2#12+1#12 GND � j T O <br /> MOTOR -— (D Q � C <br /> DISCONNECT � � 06 = <br /> MUA1 115 V/1-864 VA 8.4 MANUAL - B2-34 1/2"C-2#12+1#12 GND 3 .O <br /> MOTOR (D <br /> DISCONNECT O <br /> MUA2 115 V/1-1440 VA 13.4 MANUAL - HV-19 1/2"C-2#10+1#10 GND i O <br /> MOTOR Q N <br /> DISCONNECT z <br /> Cl) 0 <br /> m <br /> I. . <br /> c E <br /> 2) C: o <br /> 0 U 0) <br /> C (Z E) W <br /> 0 Q > <br /> U <br /> Cz •— <br /> Q o c <br /> C. <br /> C U Q cn <br /> 0E0Z3 x <br /> � m o <br /> cu Q 2 – <br /> -0 E <br /> 7 O C= <br /> Cz C Q 0- <br /> 0 O <br /> KHF <br /> Q KHF-2 O <br /> KHF2 KHF1 MUA-1 RTU1 <br /> W <br /> I KHF3 <br /> IV-21 KHF-1 B2-34 w <br /> F- <br /> W o <br /> \n J N <br /> B2-31,33, 5 <br /> HV-13,15,17 LO <br /> O < <br /> \ O MUA1 B2- ,39,41 Q z U <br /> KHF W <br /> (E)REFRIGERATION EQUIPMENT CURB 36x3O � � <br /> B2-3 U <br /> (n O <br /> (E)RTU-1 = ' z <br /> KHF4 N <br /> H-19 <br /> ff ACCESS P IM , <br /> �MKkFRIGERATION EQCURB(B)MHRIGERATION EQUIPMENT CUR Q <br /> HV-7,9,11 ACCESS PANEL <br /> • <br /> MUA2 B2-38,40,42 M <br /> U - <br /> 0 WP,GFI <br /> (E)SPARE CUR <br /> (E)RTU-5 RTU5 <br /> HV-19 <br /> (E)RTU-3 <br /> - — - HV-1,3,5 P-37,39,41 <br /> i <br /> F71--38,40,42 <br /> LEr <br /> k < <br /> (E)RTU-6 0 z <br /> J <br /> Q <br /> (E RTU4 <br /> (E)R <br /> H-19 <br /> RTU6 TU-2 RTU2 <br /> U <br /> i > w <br /> J <br /> LuU- <br /> O <br /> O <br /> WP,GFI <br /> OO <br /> QROF ES S/pN <br /> C. Sal F� <br /> Z <br /> w No. E14303 m <br /> O * Exp. 6-30-21 <br /> O <br /> O 9TF CF CAO <br /> Drawn: RCS <br /> Date: 8.6.18 <br /> Plan Check 10.23.18 <br /> Revised: Plan Check 1.29.19 <br /> H C S ENGINEERING, INC. <br /> CONSULTING ELECTRICAL ENGINEERS <br /> 1 ROOF ELECTRICAL PLAN STO FEATHER RIVER DRIVE, SUITE F <br /> STOCKTON, CA 95219 (209) 478-8270 E3m5 <br /> SCALE: 1/4" - 1'-0" email address richard@hcs-eng.com <br /> Project#: 2017.xxx Drafter: RCS Engineer: RCS <br /> K:\2018\201-300\Papavalous\PAPAVALOS ELECTRICAL Plan Check Set.rvt <br />