My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2021
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
H
>
HOYT
>
1750
>
1600 - Food Program
>
PR0161169
>
COMPLIANCE INFO_2021
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/11/2022 4:15:41 PM
Creation date
10/27/2021 9:28:27 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
1600 - Food Program
File Section
COMPLIANCE INFO
FileName_PostFix
2021
RECORD_ID
PR0161169
PE
1612
FACILITY_ID
FA0000996
FACILITY_NAME
FOOD & FUN CONCESSIONS
STREET_NUMBER
1750
STREET_NAME
HOYT
STREET_TYPE
LN
City
MANTECA
Zip
95336
APN
212612003
CURRENT_STATUS
02
SITE_LOCATION
1750 HOYT LN
P_LOCATION
04
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\jcastaneda
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
18
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
4"VANDAL PROOF <br /> PLUMBING FIXTURE SCHEDULE - CONCESSION BUILDING VENT CAP- <br /> CAST IRON <br /> QTY FIXTURE DESCRIPTION PRC # <br /> r�A`qp 1/2"HIGH POINT BLEED VALVE <br /> 1 PRESSURE GAUGE- 100 psi. PROFLO- PFXPG100K(FOR DOWNSTREAM) K1689 \��\ 1 it � CHECK VALVE <br /> 1 PRESSURE GAUGE-200 psi. PROFLO- PFXPG200K(FOR UPSTREAM) K1689.5 1 <br /> 1 CHECK VALVE- 1 1/2"-Spring Type; Sweat NIBCO #S-480-Y-LF K1568.7 1 �� 1 PRESS. REDUCING VALVE <br /> 1 WATER FILTER- 1 1/2" KEYSTONE CG10 K1591/92/94 4"CO ��\ i PRESSURE GAUGE <br /> I SHUT <br /> 1 BALL VALVE- 1 1/2" NIBCO S-FP-60ON K1566 I MOP SINK \��� \1� OFF WATER FILTER <br /> 3 3-COMP I VALVE <br /> 1 BALL VALVE- 1 1/4"(Prep for future tank) NIBCO S-FP-60ON K1563 1 MOP SINK SINK I `' H.B. <br /> TBD BALL VALVE- 1/2"(Isolation, drain &bleed valve) NIBCO S-FP-60ON K1560 I 3 4 1 2.5 <br /> WASTE AND VENT PIPING: 3 COMP. SINK I WATER PIPING: 0 1 <br /> TBD HAMMER ARRESTOR PPA SWA K1590 4 \ r2"CO y <br /> 1 HOSE BIBB- Interior ACORN#8121 CP-LF K1575 - FIXTURE UNITS 14 LAV <br /> - FIXTURE UNITS 9.5 � <br /> 1 RELIEF VALVE-For COMBO-1/2" Relief/BleedValve PEX COMPRESSION ANGLE STOP VALVE#ULF4410500 K7910 PROVIDE 1 - DEVELOPED LENGTH 100' S.S.-BACKFLOW PREVENTER F�O� <br /> - SIZE OF BUILDING FLOOR DRAINS 2" AIR GAP FOR SODA MACHINE&ICE MAKER \ <br /> 1 VENT CAP-4" SMITH 1748 K1582 \ - ELEVATION DIFFERENCE 01 LOW <br /> 1 CURB STOP- 1 1/2" MEULLER H-15015 K1585 - SIZE OF BUILDING MAIN SEWER 4" F.S. \ \ a - BUILDING REQ. PRESSURE HOT WATER LINE POINT <br /> 6 S.S.-BACKFLOW PREVENTER 46 to 60 HAMMER DRAIN <br /> 1 WATER HEATER- 12 KW- In-line REFER TO ELECTRICAL(E-1) - AGGREGATE AREA 12.566 SQ/IN I FOR SODA MACHINE&ICE MAKER - BUILDING SUPPLY SIZE 1 1/2" ARRESTOR LOW COLD WATER LINE 1 1 /2 <br /> 1 MOP SINK-24"x24"X10" MUSTEE 63M K1158 ���bbb POINT <br /> 1 MOP SINK FAUCET AMERICAN STANDARD#8354.212 K1610 TO 4" MAIN Z"DRAIN LINE - STREET PRESSURE "TBD" BY OTHERS DRAIN <br /> 1 MOP HANGER PROFLO PF 245 K1680 SEWER LINE - METER SIZE "TBD" BY OTHERS 1 <br /> 1 3-COMPARTMENT SINK- L Type ADVANCE TABCO#FC-K6-18D (OR EQUAL) D.W.V. ABOVE GRADE . . . .. . . PVC SCH 40 OR ABS SCH 40 ABOVE FLOOR <br /> 2 3-COMPARTMENT SINK FAUCET CHICAGO 445-DJ18CP(w/EXTENDER) K1605 <br /> 1 HAND SINK-Vitreous China ZURN #25344 K1151 D.W.V. BELOW GRADE . . . .. . . PVC SCH 40 OR ABS SCH 40 BELOW FLOOR <br /> WATER LINE ABOVE GRADE . . . . . . . TYPE "L" COPPER ABOVE FLOOR <br /> 1 HAND SINK FAUCET- Hot& Cold AMERICAN STANDARD#7500.170 K1706 GENERAL NOTES: <br /> 1 FLOOR SINK WATTS MODEL#FS-743-NH-150 K1612 - SIZED TO 2019 CALIFORNIA PLUMBING CODE WATER LINE BELOW GRADE . . . . . . . TYPE " K" COPPER BELOW FLOOR <br /> 1 BACKFLOW DEVICE- 1/2" (For Soda& Ice Machine) WATTS MODEL#SS009 (STAINLESS STEEL) 411 <br /> - D.W.V. MATERIAL - P.V.C. or A.B.S. NOTE : THIS WATER SYSTEM IS DESIGNED WITH A <br /> - D.W.V. UNDERGROUND MATERIAL - P.V.C. or A.B.S. 11 MAXIMUM DEVELOPMENT LENGHT OF 100ft. FROM <br /> AS PER 2019 CA GREEN BUILDING STANDARDS � GENERAL NOTES: � ��2 THE METER TO THE BUILDING. <br /> PIPE MATERIAL CHAPTER 5 SECTION 5.303 - INDOOR WATER - CONTINUATION OF WASTE TO MAIN SEWER TO BE <br /> of USE : DONE ON SITE BY OTHERS. - SIZED TO 2019 CALIFORNIA PLUMBING CODE ----------------------------------------- <br /> Of 01- Q o - POTABLE WATER MATERIAL - COPPER BUILDING PIPE SIZE IS 1 1/2" <br /> ILL] LU 3: _ - LAVATORY METERING FAUCETS SHALL - ALL FLOOR DRAINS SHALL TRAP IN UTILITY CHASE <br /> PIPE SCHEDULE o o > o 0 m AND HAVE REMOVABLE TRAPS FOR WINTERIZATION. <br /> NOT EXCEED 0.20gal. PER CYCLE. <br /> 0 G 0 = o Q - HOT & TEMPERED WATER LINES (IF ANY) TO BE INSULATED <br /> J Y CD <br /> 0_ o -FAUCET IN CONCESSION SHALL NOT EXCEED - FLOOR DRAIN TRAPS TO CONNECT TO D.W.V. IN �'' "UTILITY BOX - BY OTHERS" <br /> X � LU z Uj 2.2 gpm. UTILITY CHASE WITH STAINLESS STEEL BAND WASTE STUB & - HAMMER ARRESTORS INSTALLED TO CODE <br /> TYPE OF SERVICE � 0 Q & NO HUB COUPLING. F� "UTILITY BOX - BY OTHERS" <br /> � 0 O� CLEAN -OUT IN BOX BY OTHERSWATER <br /> OF WATER MAIN TO BE DONE ON SITE F10� WATER BOX & SHUT OFF <br /> ABOVE GROUND ✓ - P-TRAPS ON ACCESSIBLE FIXTURES INSULATED <br /> WATER O <br /> BELOW GROUND ✓ �l. VALVE IN BOX (V <br /> ABOVE GROUND �/ - V.T.R. SHALL BE CAST IRON WITH VANDAL CAP Mq�N - AS PER CODE : A EXPANSION TANK WILL BE PROVIDED 7 0 <br /> MIMTO 24" BELOW ROOF. �UN� S�c� FOR A CLOSED WATER SYSTEM OR THERMAL EXPANSION. 7i2,, CV <br /> SANITARYBELOW GROUND <br /> ABOVE GROUND ✓ - LAVATORY TRAPS IN UTILITY CHASE FRC'�'O�jF - SLOPE ALL WATER PIPING TO LOW POINT DRAIN DRAINS <br /> VENT BELOW GROUND ✓ SHALL HAVE DRAIN PLUGS FOR WINTERIZATION. N�/ FOR WINTERIZATION. RG',QO� <7�F CY) <br /> ABOVE ROOF ✓ SLOPE ALL D.W.V. PIPING 1/4" NOM. - WATER HEATER SHALL BE ANCHORED OR STRAPPED ti0� \ O <br /> -- <br /> DRAIN LINE TO BE SLOPED TO MAIN SEWER LINE. PER CODE. <br /> U) <br /> -INSTALL GRATES AT FLOOR OPENING IF APPLICABLE. - FURNISH & INSTALL SERVICE CURB BOX NORMALLY 6' (— <br /> OUTSIDE BUILDING. z <br /> - SITE CONNECTIONS TO WATER MAIN & MODULE LINE LJJ <br /> CONNECTIONS ARE CLEARLY LABELED. - SITE CONNECTIONS TO WATER MAIN & MODULE LINE <br /> CONNECTIONS ARE CLEARLY LABELED. <br /> WASTE & VENT - PIPING ISOMETRIC WATER PIPING ISOMETRIC o <br /> 0 <br /> z <br /> O <br /> F___ <br /> ( <br /> -- <br /> "BY OTHERS" v <br /> "BY OTHERS" 1 1/2 <br /> / UTILITY BOX MARKED <br /> � ___ "MAIN WATERLINE <br /> (MOUNTED WITH \ 4"MAIN SEWER LINE / �+ \ UTILITY BOX \ — --(UNDERGROUND)— O "WATER"-W/IN 6 FT.OF <br /> INTERIOR WALL—", <br /> ALL 13/16" UNI-STRUT II (UNDERGROUND) .J MARKED"SEWER" I BUILDING <br /> DIACHROMATE \\EO: <br /> O 4,. W H W/IN 6 FT. \ I O O MVV <br /> WATER BOX& <br /> WASTE STUB OF BUILDING gal. SHUT-OFF IN BOX 7 <br /> U &CLEAN OUT IN BOX <br /> VERIFY LOCATION / O / O O <br /> U <br /> II II APPROVED <br /> By BADICO a CA <br /> FINISH FLOOR <br /> \ \ Departrnent of HOuSirrg <br /> d and Corrrnffity <br /> O <br /> \ _ O— — — — \ D&AAopffKmt approved <br /> m - - \ m - - \ <br /> third party design Q <br /> 3" N.H. BAND 3' CN <br /> S.S. BACKFLOW approval agency U <br /> 3" PIPE NIPPLE - DM 20 <br /> PREVENTER <br /> APPROVAL EDCPftATION U <br /> 272 <br /> 3"SWEEP TO MAIN DRAIN D <br /> 3" P-TRAP ATE DATE <br /> F II Apr 6,2020 Ad 31,2021 � <br /> FLOOR SINK DETAIL APPROVAL NO. m <br /> � - a <br /> L I1-11 0 <br /> z <br /> o <br /> COPPER \ \ \ J <br /> GROUND WIREHIGH POINT <br /> �\ <br /> CHECK VALVE BLEED VALVE \ <br /> 200 psi I = = I I I z <br /> PRESSURE 1 1/2" O <br /> GAUGE <br /> n n 1 <br /> MAIN�� 100 psi <br /> SHUT-OFF <br /> PRESSURE LLI <br /> 1 1/2" INE WATER GAUGE \ \ \ \ U <br /> HOSE BIBB <br /> PLASTIC FILTER z / / <br /> O — z <br /> z F- O O <br /> GROUND WIRE O w <br /> \ \ <br /> FROM ELECTRIC v OJ <br /> PANEL w U_ no <br /> no \ \ <br /> Q <br /> PRV & FILTER COMBO MANIFOLD 1 PLUMBING PLAN - WASTE & VENT 2 PLUMBING PLAN - WATER SUPPLY w <br /> P-1 <br /> SCALE: NOT TO SCALE p_1 SCALE: NOT TO SCALE DO NOT SCALE-DIMENSIONS PRESIDE <br /> 2436 SHEET=SCALE AS NOTED <br /> 11x17 SHEET=NTS <br /> No. Description DateCOPYRIGHT 2020, PUBLIC RESTROOM COMPANY THIS PUBLIC PROJECT OWNER: PROJECT NAME AND LOCATION: SHEET TITLE: Drawn by: NS / EVE Job No. 10338B = <br /> CONSTRUCTION DOCUMENTS MATERIAL IS THE EXCLUSIVE PROPERTY OF PUBLIC B OOM Checked b KIM <br /> RESTROOM COMPANY AND SHALL N o T BE RCOMPANY CITY of MANTECA NORTHGATE PARK - CONCESSION BUILDING PLUMBING PLAN & y <br /> 03/16/2020 REPRODUCED, USED, OR DISCLOSED TO OTHERS Building Better Places To Go. Current Date: 03/16/2020 <br /> EXCEPT AS AUTHORIZED BY THE WRITTEN 2587 Business Pkwy,Minden,NV 89423 Manteca, CA Manteca, CA SCHEDULES P 1 O <br /> PERMISSION OF PUBLIC RESTROOM COMPANY <br /> Ph:888-888-2060 1 Fax:888-888-1448 1 1 1 1Start Date: 02/03/2020 7 <br />