My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2021
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
H
>
HOYT
>
1750
>
1600 - Food Program
>
PR0161169
>
COMPLIANCE INFO_2021
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/11/2022 4:15:41 PM
Creation date
10/27/2021 9:28:27 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
1600 - Food Program
File Section
COMPLIANCE INFO
FileName_PostFix
2021
RECORD_ID
PR0161169
PE
1612
FACILITY_ID
FA0000996
FACILITY_NAME
FOOD & FUN CONCESSIONS
STREET_NUMBER
1750
STREET_NAME
HOYT
STREET_TYPE
LN
City
MANTECA
Zip
95336
APN
212612003
CURRENT_STATUS
02
SITE_LOCATION
1750 HOYT LN
P_LOCATION
04
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\jcastaneda
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
18
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ELECTRICAL FIXTURE / EQUIPMENT SCHEDULE & SYMBOLS <br /> SYMBOL Q'TY RATING CALC. LOAD DESCRIPTION MODEL PRC# HEIGHT TO TOP COMMENTS <br /> PANEL 1 200 AMP MAIN BREAKER 200 AMP MAIN BREAKER 120/208 THREE PHASE w/PLUG-ON BREAKERS; NEMA 1 ENCLOSURE SQUARE D QO SERIES-42 SPACES 72" FURR-OUT 6" <br /> LIGHT-EXTERIOR ® 15 4 15 WATTS 15 VA 15 WATT LED LUMINAIRE SWP610-15W-4000K-12OV-OP-BRZ L1162.5 108" ON PHOTOCELL/BY PASS SWITCH <br /> LIGHT-CONCESSION ®36 5 36 WATTS 36 VA 36 WATT LED GREENLIGHTING AL42L L1108 ON MANUAL SWITCH <br /> LIGHT-UTILITY CHASE ®36 1 36 WATTS 36 VA 36 WATT LED GREENLIGHTING AL42L L1108 ON MANUAL SWITCH <br /> RECEPTACLE GFCI 13 1500 WATTS 1500 VA DEDICATED 20 AMP GFCI -DUPLEX RECEPTACLE LEVITON#GFNT2-W L1876 48" <br /> RECEPTACLE DC 4 1500 WATTS 1500 VA DEDICATED 20 AMP GFCI - DUPLEX RECEPTACLE LEVITON#CR20W L1878 48" ON GFCI BREAKER <br /> PHOTOCELL Q 1 1800 WATTS RATED PHOTOCELL INTERMATIC EK4336S L1896 MOUNTED ON EVE CONTROL EXTERIOR LIGHTING <br /> SWITCH (1 BY-PASS) $ 2 SINGLE POLE SWITCH LEVITON 1221-W L1868 48" (1)BY-PASS SWITCH ; (1)CONTROL UTILITY CHASE LIGHTS <br /> SWITCH (SENSOR) $OS 1 SINGLE POLE SENSOR SWITCH LEVITON-MODEL"TBD" 48" CONTROL CONCESSION LIGHTS <br /> AIR CURTAIN 1 408 WATTS 408 VA AIR CURTAIN -WHITE BERNER SLC07-1042A L1388 WITH DOOR SWITCH <br /> AIR CURTAIN DOOR SWITCH 1 DOOR SWITCH FOR AIR CURTAIN BERNER#9403SDO20-P L1000 CONTROL AIR CURTAIN <br /> WATER HEATER-50 Gal. 1 12 KW 12000 VA ELECTRIC WATER HEATER-LOW BOY-50 Gallon AO SMITH MODEL#DEL-50 <br /> HVAC- CONCESSION 2 2500 WATTS 2500 VA THRU -WALL MOUNTED FRIEDRICH SG SERIES PTAC MODEL#PDH15K5SG <br /> NOTES: <br /> N <br /> 1. ALL CONDUCTORS ARE COPPER WIRES. <br /> 2. RATING OF STANDARD PANEL IS 22,000 A.I.C. N L1 LO H <br /> 3. WIRING METHOD IN METALLIC CONDUIT. <br /> 4. INSTALL CEE GROUND IN SLAB, TERMINATING IN MECH. ROOM N H � —ON/OFF SWITCH • <br /> 5. GREEN GROUNDING CONDUCTOR IN ALL RACEWAYS. PHOTOCELL <br /> INTERIOR LIGHTS ON SENSOR/ MANUAL SWITCH MOUNTED <br /> 6. SITE CONNECTION POINT FOR ELECTRICAL SERVICE AND MODULE LINE ON EVE <br /> CROSS OVERS ARE CLEARLY LABELED. (FOR MULTI-MOD. BUILDING ONLY) 30"x36° ELEC. PANEL <br /> 7. ALLOWABLE WATTAGE FOR BUILDING LIGHTING IS 346.458 N CLEAR APPROACH <br /> 53.79 SQ/FT.ACC ALL GENDER 1 x 0.60 WATTS PER SQ/FT FOR 32.274 WATTS. PHOTOCELL <br /> 53.79 SQ/FT.ACC ALL GENDER 2 x 0.60 WATTS PER SQ/FT FOR 32.274 WATTS. <br /> 204.35 SQ/FT. CONCESSION x 1.20 WATTS PER SQ/FT FOR 245.22 WATTS. W B R H <br /> 66.71 SQ/FT. MECH. ROOM x 0.55 WATTS PER SQ/FT FOR 36.690 WATTS. <br /> 0 Ii GFCI GFCIi i _ <br /> THE INSTALLED WATTAGE FOR THIS BUILDING IS 210 7- � ' <br /> N H BY-PASS SWITCH "TEST" IN / I i i i O O WH V / / I <br /> "ON" POSITION <br /> ONE-LINE DIAGRAM EXTERIOR LIGHTS BY-PASS "ON" �/ GFCI �I #12 #1Q <br /> ✓��� 2� <br /> 200 AMP MAIN BREAKER / I • �Y / <br /> 120/208 30 4W � � 0 � /� 0 <br /> LIFER GROUND REQUIRED <br /> 14 0 #1 �� z/)---------- I lilt ,,,I � <br /> N <br /> #4 Cu 0— \ C) <br /> O <br /> \ UTILITY <br /> WATER T_ 2" P.V.C. \ CHASE/ 1 <br /> #4 Cu <br /> CEE #4 Cu GRD. ROD <br /> \ . <br /> STORAGE <br /> (ON SITE BY OTHERS <br /> IF REQUIRED) o o z <br /> \ a LU <br /> — — , #4 <br /> #18 <br /> ------- <br /> PANEL SCHEDULE 240 VOLTS REC. m1 _ _ _ _ _ . <br /> I � <br /> FOR AIC SYSTEM <br /> PANEL : 120/208 VOLT 3 PHASE 4 WIRES 200 AMP MAIN BKR. 200 AMPERES BUS 11 \ Q <br /> #23-25 z <br /> NOTE: ALL CONDUCTORS COPPER 200 AMP PANEL ON GFCI 1�RZ I I ICE MCHN GFII O <br /> CIRCUIT CIRCUIT <br /> CKT DESCRIPTION BREAKER WIRE A B C WIRE BREAKER DESCRIPTION CKT BREAKER 1 #5� #6 �� <br /> TRIP AMPS SIZE TOTAL TOTAL SIZE TRIP AMPS NO. LC _ J I DC ON GFCI7 <br /> U <br /> 3 WATER EHEATER 6VI 0 $' 6000 6000 6060 60 12 20 EXTERIOR LIGHTS 6045 45 12 20 UTILITY CHASE LIGHTS/STO.LIGHTS 4 REF BREAKER <br /> 5 DED RECEPTACLES-FREEZER 20 12 1500 3000 1500 12 20 DED RECEPTACLES-ICE MACHINE 6 1 #�I SODA #2 240 VOLTS REC. <br /> 7 DED RECEPTACLES-REFRIGERATOR 20 12 1500 3000 1500 12 20 DED RECEPTACLES-SODA MACHINE 8 f� <br /> 9 DED RECEPTACLES-GFCI 20 12 1500 3000 1500 12 20 DED RECEPTACLES-GFCI 10 IDC 1 #8 ' GF,'I FOR A/C SYSTEM ���) <br /> ^ <br /> 11 DED RECEPTACLES-GFCI 20 12 1500 3000 1500 12 20 DED RECEPTACLES-GFCI 12 I DC I V <br /> 15 CONCESSION LIGHTS 20 12 150 1650 1500 12 20 DED RECEPTACLES-GFCI 114 16 1 1 #28-3o z <br /> 0 <br /> 17 DED RECEPTACLES-GFCI 20 12 1500 3000 1500 12 20 DED RECEPTACLES-GFCI 18 L -u #24 la U <br /> 19 DED RECEPTACLES-GFCI 20 12 1500 1908 408 12 20 AIR CURTAIN 20 . <br /> 21 DED RECEPTACLES-GFCI 20 12 1500 3000 1500 12 20 DED RECEPTACLES-GFCI 22F�Y <br /> 23 HVAC-CONCESSION 20 12 1250 2750 1500 12 20 DED RECEPTACLES-GFCI 24 #^ I \ <br /> 25 VV IV VV VV 1250 1250 26 <br /> 27 DED RECEPTACLES-GFCI 20 12 1500 2750 1250 12 20 HVAC-CONCESSION 28 GFCI <br /> 29 DED RECEPTACLES-GFCI 20 12 1500 2750 1250 <br /> �� �� �� �� 30 ' L J <br /> 31 32 <br /> 33 34 / <br /> 35 36 / <br /> 37 38 \ <br /> 39 40 \ Q <br /> 41 42 N \ 1 <br /> BUS MATERIAL : COPPER SUB TOTALS 13868 14795 14500 NOTES : CONCESSION <br /> MOUNTING : SURFACE TOTAL CONNECTED ------ <br /> AIC RATING 10,000 LOAD 43163 I N <br /> #11 ----- 4-1 <br /> - <br /> �1 #29 m <br /> ELECTRICAL PLAN REVIEW LOAD CALCULATIONS 2-1 <br /> PANEL : 120/208 VOLT 3 PHASE 4 WIRES 200 AMP MAIN BKR. 200 AMPERES BUS \\ #13 #20 #17 #19 I� #21 #27 �I GFCI � <br /> II II II <br /> GFCI <br /> CONNECTED LOAD CALC. LOAD \ i i i // z <br /> LIGHTING A4R-C+RT-AIN APPROVED <br /> EXTERIOR 60 V.A. x 125 % = 75 V.A. OS H GFCI GFCI I IGFCI GFCI I I , J <br /> INTERIOR 180 V.A. x 125 % = 225 V.A. <br /> — — — — — — — By RADCO a GA <br /> — Deparbnent of Housing <br /> EXIT V.A. x 125 % = V.A. and _ m <br /> EMERGENCY V.A. x 125 % = V.A. I z <br /> ROOF VENT(FAN) V.A. x 125 % = V.A. \ DmdopffKmt approved O <br /> X V.A. x 125 % = V.A. \ third party design <br /> U) <br /> LIGHTING <br /> THRU 10,000 V.A. x 100% = V.A. ��� w <br /> \ DM920272 <br /> OVER 10,000 V.A. x50%= V.A. \ APPROVAL DCPFL TION U <br /> DED. RECEPTACLE-GFCI (13) 19500 V.A. x 100% = 19500 V.A. \ DATE DATE z <br /> DED. RECEPTACLE (4) 6000 V.A. x 100% = 6000 V.A. \ Ali 312W1 1 f0 U <br /> DED. REC. (2- HVAC) 5000 V.A. x 100% = 5000 V.A. APPROVAL NO. <br /> WATER HEATER(1) 12000 V.A. x 100 % = 12000 V.A. 5914150 1 <br /> AIR CURTAIN 408 V.A. x 100 % = 408 V.A. <br /> TOTALLOAD 43163 TOTALLOAD 43208 <br /> TOTAL KVA 43.163 TOTAL KVA 43.208 1 ELECTRICAL PLAN <br /> CONNECTED AMPS CALCULATED SCALE: NOT TO SCALE W <br /> LOAD 119.812 LOAD AMPS 119.936 E-1 <br /> DO NOT SCALE-DIMENSIONS PRESIDE ' ' <br /> 24x36 SHEET=SCALE AS NOTED Q` <br /> 1 1x1 7 SHEET=NTS .^ <br /> a No. Description Date COPYRIGHT 2020, PUBLIC RESTROOM COMPANY THIS PUBLIC PROJECT OWNER: PROJECT NAME AND LOCATION: SHEET TITLE: Drawn by: NS/ EVE ,lob No. 10338B = <br /> CONSTRUCTION DOCUMENTS MATERIAL IS THE EXCLUSIVE PROPERTY OF PUBLIC RESTROOM Checked b KM <br /> o RESTROOM COMPANY AND SHALL NOT B E NY COMPACITY of MANTECA NORTHGATE PARK - CONCESSION BUILDING ELECTRICAL PLAN & y N <br /> o REPRODUCED, USED, OR DISCLOSED TO OTHERS N <br /> 03/16/2020 Building Better Places To Go. Current Date: 03/16/2020 <br /> m EXCEPT AS AUTHORIZED BY THE WRITTEN 2587 Business Pkwy,Minden,NV 89423 Manteca, CA Manteca, CA SCHEDULESE- 1 <br /> O <br /> PERMISSION OF PUBLIC RESTROOM COMPANY Ph:888-888-2060 1 Fax:888-888-1448 Start Date: 02/03/2020 z <br />
The URL can be used to link to this page
Your browser does not support the video tag.