Laserfiche WebLink
for a septic disposal area. Percolation test results are discussed in the following <br />section. <br />Percolation Test <br />A shallow percolation test was conducted in the proposed septic disposal area of the <br />Site. The soil boring discussed above was used for the percolation test hole. <br />Percolation test procedures conformed to San Joaquin County Environmental Health <br />Department policy. <br />Preparation and Presaturation of Percolation Test Holes <br />After the boring was advanced by hand auger and the soil logged, the test hole was <br />completed for the percolation testing. Approximately two inches of pea gravel were <br />placed in the bottom of the open soil boring, followed by a 2.0 -inch diameter PVC pipe <br />with perforations on the bottom. Pea gravel was then used to backfill a few inches of <br />the annular space. <br />Live Oak presaturated the percolation test hole approximately 24 hours prior to the <br />percolation testing. The hole was filled with water to a height of 12 inches above the <br />bottom of the boring for the presaturation. On the day of testing, the hole was found to <br />be intact and dry. <br />Percolation Test Procedure <br />Live Oak conducted the percolation test for the boring on September 2, 2021. Due to <br />the soil type present, a four-hour test was selected. Water level measurements were <br />taken every 30 minutes during the four-hour period. The last 30 minutes of the test <br />were observed by Michael Suszycki, Registered Environmental Health Specialist at the <br />San Joaquin County Environmental Health Department. <br />An electronic well sounder with a depth accuracy of 1/100th foot was utilized for the <br />water level measurements. The water level was measured against a fixed reference <br />point on the well casing. Measurements were recorded on the data sheet in decimal <br />feet. When necessary after measuring the water level, each hole was refilled with water <br />to a level of approximately six inches above the bottom of the hole. <br />Percolation Test Results <br />The completed percolation test form is included in Appendix 3 of this report. The form <br />was signed by Mr. Suszycki and indicates a percolation rate for the hole based on the <br />final water drop observed. <br />Per San Joaquin County Environmental Health Department's definition, a shallow <br />percolation test hole has a depth between 18 and 42 inches; a satisfactory percolation <br />LOGE 2144 Page 6 <br />