My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
SR0084296_SSNL
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
A
>
ADA
>
11671
>
2600 - Land Use Program
>
SR0084296_SSNL
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/29/2021 4:39:26 PM
Creation date
10/29/2021 4:18:50 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2600 - Land Use Program
FileName_PostFix
SSNL
RECORD_ID
SR0084296
PE
2602
FACILITY_NAME
11671 E ADA AVE
STREET_NUMBER
11671
Direction
E
STREET_NAME
ADA
STREET_TYPE
AVE
City
STOCKTON
Zip
95215
APN
10327008
ENTERED_DATE
9/30/2021 12:00:00 AM
SITE_LOCATION
11671 E ADA AVE
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\tsok
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
69
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
rate for a shallow test is greater than or equal to 1 minute per inch (min/in) but less than <br />or equal to 60 min/in drop. For the Site to utilize a standard septic system, one <br />percolation test hole must demonstrate a satisfactory percolation rate within the <br />proposed septic system disposal field. <br />Details and results of the percolation testing are summarized in the following table. <br />Table 2. Percolation Test Summary <br />Test No., Percolation Test Percolation Rate Test Duration Comments <br />Date Tested Depth (ft.) (minutes/inch) (see notes) <br />P1 -S, <br />9/2/2021 3.25 5.10 4 hr. Satisfactory perc. <br />Shallow Test rate <br />Note: A satisfactory percolation rate for a "shallow" test is greater than 1 but less than or equal to 60 minutes per <br />inch. <br />Discussion of Percolation Test Results <br />The soils within the proposed sewage disposal area of the Site have demonstrated a <br />satisfactory percolation rate for the use of a standard septic system in accordance with <br />the requirements of the San Joaquin County Environmental Health Department. This <br />percolation test is considered representative of soils within a 100 -foot radius of the test <br />location. <br />Discussion of Septic System Sizing <br />Septic system construction utilizing leach lines with seepage pits should follow the San <br />Joaquin County On -Site Wastewater Treatment Systems Standards (2017) where <br />applicable. <br />LOGE 2144 Page 7 <br />
The URL can be used to link to this page
Your browser does not support the video tag.