Laserfiche WebLink
Add.itionW rcyuirernents for surface conscructibo feature,; are contained in Section 10 Of the Water Well <br /> Standards, <br /> Section 9. casj lg. <br /> Vent pipe,anode access tubing, and any other tubular irlateri3ls that pas, through the interval to be fillcct and <br /> scaled are all colaside red casing for the purpc c of Ihese standards. Materials used for ct'cthadic protection well <br /> cxiing generally shall meet the requirements for using materials aad their installation in Section 12 of the <br /> Water Well Standards. Variance from the standards shill be at the approval of the enforcing agency, It is <br /> tceurnmendcd tbaL practices prescribed by ttie Mitional AssociEtfion of Corrosion Enghic42�rs also be followed <br /> in 1bcc design and instaf.lation of gas vents and electrical conduit. <br /> Cathodic protection well using should be al least 2 inches in internal diameter io facilitate eventual well <br /> destruction. <br /> Section 10. Scaling-Off Strata. <br /> If a cathodic protection well penetrates a stratum or strata below the minimum required annular surface seal <br /> depEh specified in Section 7, above and that slrxturn contains poor-quality water, pollutants, or coil t3lilinailis <br /> that could rnix vvith and degrade }vales contained in other str a peneErated by the well, additional annular <br /> sealing material shall be placed helnw the minimum rc4uired annular surface seal to prevem t mixing and water- <br /> quality degradation. <br /> The following mirtimum requirements shall he nto-served For isolating Zones containing poor-quality water, <br /> pollutants, or contaminaras for various Eases: <br /> Case I. Up,per Stratum. If a stratum containing poor-quality water, pollutants, or Mnlaminants lies above <br /> a stratimn to he protected,annular seat material shall extend from the top of the stratum conutining the poor- <br /> quality water, pollutants, or contaminaRts clown t❑ at least 10 feel into the confining layer separating the: Two <br /> strata, ar through the entire thickness of the confining layer, whichever is least. <br /> mzc 2. La cr Stratum. If a mraturn containing poor-quality wider, pollutants, or cowarrtinants lies below <br /> a stratum to be protected, the annular spat-oppnMte the Stratum to bC protected shall he scaled along its full <br /> length. 'Fite sc l shall extend at least 10 iiect into the confining layer separating She two strata,or thri ugh ibe, <br /> eralrc thickness or the oonfining kiyer, whichever is beast. <br /> C' se_3. NJUItiyle Strata. <br /> a. Where two or more strata containing peonquality water, pollutants, or eontarninants am adjacent to <br /> Me anOther And overlie a siralurn to he proteetW, the annular space opposite the strata Containing <br /> poor-quality water, pollutants, or contarnin:inis and uppasilc ull interbedded cbnfi:ning layers shall he # <br /> sralcul, The annular seat shall exiend at least 10 feet down into, or completely through, whichever is <br /> least, theconfiningIaycrseparatingthcs[rat a con tainingpoor-quaIityw•atcr,poll utants,orconzarninants ` <br /> and the underlying stratum to be protected, ■ <br /> b. Where two or more. strata containing poor-Pretty waxer, pollutants, or contaminants underlie a <br /> stratums to be pratectect, the annular spuEe opposite the stratum to be protected shall be sealed. The <br /> seal shall continue Mourn at least 10 rect info.. or completely through, whichever is least, The confining <br /> layer wparating the stratum to be protected stud the underlying strata containing poor-quality water, <br /> pollutarn-9 or contamirtarits. <br /> -6 - <br /> 'I <br />