Laserfiche WebLink
d . An approved fire alarm system shall be installed in accordance with 2022 CFC § 907 . 2 and 2022 <br /> NFPA 72 . <br /> e . Fire Department Development Fees for all new buildings must be paid in accordance with the City <br /> of Lathrop ' s Ordinance and Resolutions adopting the fee schedule . <br /> f. An approved Fire Flow test shall be conducted prior to ground breaking to determine the allowable <br /> Fire Fighting capabilities for the site . <br /> g . An approved water supply for fire protection , either temporary or permanent , shall be made <br /> available prior to commencing construction beyond the foundation stage , or as soon as combustible <br /> material arrives on the site . <br /> h . Deferred Plan Submittals for Fire Alarm , Fire Sprinklers and Fire Underground shall be submitted <br /> directly to the LMFD . <br /> Is Approved vehicle access for firefighting shall be provided to all construction or demolition sites . <br /> Vehicle access shall be provided to within 100 feet ( 30 480 mm ) of temporary or permanent fire <br /> department connections . Vehicle access shall be provided by either temporary or permanent roads , <br /> capable of supporting vehicle loading under all weather conditions . Vehicle access shall be <br /> maintained until permanent fire apparatus access roads are available . <br /> j . The Fire Department Fire Access Roads shall meet the requirements established by the San <br /> Joaquin County Fire Chiefs Association . <br /> k . Where access to or within a structure or an area is restricted because of secured openings or where <br /> immediate access is necessary for life - saving or fire -fighting purposes , a key box is required to be <br /> installed in an approved location . Please note that a separate key box will be required for each of <br /> the two access points . The key box shall be of an approved type and shall contain keys to gain <br /> necessary access as required by the fire code official . In addition to key box ( es ) , any automatic <br /> gates shall have Opticom access ability to provide necessary access for emergency apparatus . <br /> I . Where a portion of the facility or building hereafter constructed or moved into or within the <br /> jurisdiction is more than 400 feet ( 122 m ) from a hydrant on a fire apparatus access road , as <br /> measured by an approved route around the exterior of the facility or building , on -site fire hydrants <br /> and mains shall be provided where required by the fire code official . <br /> m . Other fire & life safety requirements may be required at time of building plan review . <br /> n . Final approval is subject to field inspections . Minimum 48 - 72 - hour notice required prior to any life . <br /> safety fire inspections . Other conditions may apply at time of inspections and are subject to <br /> correction . <br /> PA-2100226 , Zone Reclassification No . PA-2100227 , & Use Permit No . PA-2100228 — Conditions of <br /> Approval 8 <br />