Laserfiche WebLink
PROJECT LOCATION <br />NOT TO SCALE <br />N <br />W KETTLEMAN LN <br />S LOWER SACRAMENTO RDPATH OF EGRESS 53'-10"PATH OF EGRESS 42'-9" <br />KITCHENMERCANTILE <br />OF SHEETS <br />SLW <br />9/11/2020 <br />20-117 <br />DRAWN <br />AS SHOWN <br />SCALE <br />DATE <br />CHECKED <br />JOB NO. <br />SHEET <br />REVISIONS BY <br />TJBPROJECT :CLIENT :LOCATION :CRUMBLS COOKIES2624 W KETTLEMAN LN, 150LODI, CA 95242JOHN GAUTHIERLODI, CAM-4.0 EXHAUST HOOD SPECIFICATIONS <br />M-4.1 EXHAUST HOOD SPECIFICATIONS <br />PLUMBING DRAWINGS <br />P1.1 PLUMBING SPECIFICATIONS <br />P1.2 PLUMBING SCHEDULES <br />P2.0 PLUMBING PIPE SIZING DIAGRAMS <br />P3.0 PLUMBING PIPING PLAN <br />P-1.0 PLUMBING DETAILS <br />ELECTRICAL DRAWINGS <br />E-1.0 ELECTRICAL SPECIFICATIONS <br />E-1.1 ELECTRICAL SCHEDULES <br />E-2.0 ELECTRICAL POWER PLAN <br />E-2.1 ELECTRICAL LIGHTING PLAN <br />E-2.2 ELECTRICAL HVAC POWER PLAN <br />ENERGY CALCULATIONS <br />T-24.1 ELECTRICAL COVER SHEET <br />T-24.2 POWER & LIGHTING PLANS <br />T-24.3 ELECTRICAL ELEVATIONS <br />T-24.4 ELECTRICAL DETAILS <br />GENERAL PROJECT INFORMATION <br />G0.0 COVER SHEET <br />G1.1 ACCESSIBILITY DETAILS <br />CORE AND SHELL DRAWINGS BY OTHERS <br />SP1.0 ADA SITE PLAN <br />ARCHITECTURAL DRAWINGS <br />A1.1 DEMOLITION PLAN, REMODEL FLOOR PLAN &RCP <br />A2.1 INTERIOR ELEVATIONS <br />A2.2 INTERIOR ELEVATIONS & RESTROOMELEVATIONS <br />A6.1 EQUIPMENT PLAN AND SCHEDULES <br />A6.2 WIRE SHELVING DETAILS <br />A6.3 FINISH DETAILS <br />A7.1 CABINETRY PLAN AND SECTIONS <br />A7.2 COUNTER DETAILS <br />A7.3 SECTIONS AND DETAILS <br />A7.4 CEILING DETAILS <br />MECHANICAL DRAWINGS <br />M-1.0 MECHANICAL SPECIFICATIONS <br />M-1.1 MECHANICAL SCHEDULES <br />M-2.0 MECHANICAL PLAN <br />M-3.0 MECHANICAL DETAILS <br />M-3.1 MECHANICAL DETAILS <br />DRAWING INDEX DESIGN CRITERIA PROJECT INFORMATIONPROJECT DIRECTORY <br />GENERAL PROJECT NOTES <br />GENERAL PROJECT NOTES <br />1 ALL DIMENSIONS TO NEW WALLS ARE TO FACE OF STUD UNLESS NOTED OTHERWISE. ALL DIMENSIONS TO EXISTING WALLS ARE TO FACE OF FINISH. EXISTING DIMENSIONS WERE PROVIDED BY OWNER. CONTRACTOR TO VERIFY PRIOR TO CONSTRUCTION. <br />CONTRACTOR TO VERIFY EXISTING CONDITIONS. DISCREPANCIES BETWEEN ACTUAL CONDITIONS AND PLANS SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT. CONTRACTOR SHALL SUBMIT SPECIFIC DISCREPANCIES FOR ARCHITECT REVIEW. <br />IN ALL AREAS OF CONSTRUCTION. PROTECT ALL EXISTING WALLS, CEILINGS, FLOORING FINISHES, EQUIPMENT, FURNITURE, ACCESSORIES, AND ALL EXISTING BUILDING ELEMENTS TO REMAIN FROM DAMAGE. THE CONTRACTOR SHALL BE RESPONSIBLE FOR PATCHING, REPAIR, AND/OR REPLACEMENTS OF ALL SUCH ITEMS AT NO EXPENSE TO OWNER IF DAMAGE OCCURS. <br />2 <br />GENERAL FRAMING NOTES <br />1 ALL DIMENSIONS AND CONDITIONS TO BE VERIFIED BY BUILDER PRIOR TO ANY WORK. <br />ALL INTERIOR WALLS TO BE 3 5/8" METAL STUDS AT 16" O.C. UNLESS NOTED OTHERWISE. PROVIDE ALL BACKING FOR EQUIPMENT AS REQUIRED. <br />ALL WORK SHALL BE IN STRICT ACCORDANCE WITH THE NOTED EDITION OF THE INTERNATIONAL BUILDING CODE (I.B.C.), AND LOCAL ORDINANCES. <br />ALL STRUCTURAL PLYWOOD SHALL BE STRUCTURAL GRADE I OR STRUCTURAL GRADE II. <br />2 <br />GENERAL THERMAL, MOISTURE, AND ACOUSTICAL PROTECTION NOTES <br />1 AIRTIGHT DRYWALL SYSTEMS SHALL BE USED (USE VAPOR BARRIERS AT ALL EXTERIOR WALLS AND CEILINGS). <br />SEAL AROUND ALL ELECTRICAL, PLUMBING, OR MECHANICAL PENETRATIONS AT EXTERIOR WALL AND IN CEILING/FLOOR OR CEILING ROOF ASSEMBLIES. <br />ALL EXTERIOR WALL INSULATION TO MATCH EXISTING. <br />2 <br />GENERAL PLUMBING, ELECTRICAL, EQUIPMENT NOTES <br />1 EXISTING CONDITIONS FOR ALL BUILDING SYSTEMS: PLUMBING, MECHANICAL, ELECTRICAL, SEWER, FIRE PROTECTION, STRUCTURAL, ETC. WERE PROVIDED BY OWNER. CONTRACTOR TO VERIFY EXISTING CONDITIONS PRIOR TO CONSTRUCTION. <br />ALL ELECTRICAL FINISH HARDWARE TO BE SELECTED BY OWNER. <br />PROVIDE (2) SEISMIC STRAPS (MIN.) FOR EVERY WATER HEATER. <br />IT IS THE RESPONSIBILITY OF THE GENERAL CONTRACTOR TO ASSURE REQUIREDPLUMBING AND ELECTRICAL SERVICE TO ALL FIXTURES AS INDICATED ON PLANS ANDAS REQUIRED BY BUILDING CODE AND OWNER. <br />THE GENERAL CONTRACTOR SHALL VERIFY AND COORDINATE WITH ALL TRADES, SIZES, AND LOCATIONS OF ALL OPENINGS FOR MECHANICAL, PLUMBING, AND ELECTRICAL EQUIPMENT, EQUIPMENT PADS FOR BASES. AS WELL AS ELECTRIC POWER, WATER AND DRAIN INSTALLATIONS, BEFORE PROCEEDING WITH WORK. CONTRACTOR SHALL PROVIDE COORDINATION DRAWINGS FOR PROPER PLACEMENT OF ALL TRADES WORK, ANY CONCERNS, SPACE LIMITATIONS OR STRUCTURAL CONFLICTS, SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT, A REASONABLE RESPONSE TIME SHALL BE ALLOWED. <br />3 <br />GENERAL FINISH NOTES <br />1 ALL INTERIOR WALLS TO BE WRAPPED WITH 5/8" GYPSUM WALL BOARD, TAPED, FILLED, AND FINISHED AS PER ROOM FINISH SCHEDULE AND OWNER. <br />SEE FLOOR PLANS AND/OR FINISH SCHEDULE FOR FINISH FLOOR MATERIALS. <br />OWNER TO SELECT ALL HARDWARE, FIXTURES, APPLIANCES, ETC. CONTRACTOR TO INSTALL AS PER OWNER. <br />ALL SPECIAL ACCESSIBILITY FACILITIES SHALL BE IDENTIFIED WITH APPROPRIATE SIGNAGE. <br />IN ALL AREAS SCHEDULED TO RECEIVE NEW WALL FINISH, CLEAN, PATCH, AND REPAIR ALL WALLS IN PREPARATION FOR NEW PAINT OR FINISH. COORDINATE REMOVAL OF EXISTING WALL ITEMS AND ACCESSORIES WITH OWNER. <br />AT WALL TRANSITIONS FROM NEW TO EXISTING WALLS, PATCH REPAIR AND/OR REPLACE GYP. BOARD AS REQUIRED TO PROVIDE FLUSH TRANSITION BETWEEN NEW AND EXISTING WALL SURFACES. <br />IT IS THE CONTRACTOR'S RESPONSIBILITY TO COORDINATE AND LOCATE ELECTRICAL, DATA, AND PHONE RECEPTACLES, SWITCHES, ETC. TO AVOID CASEWORK, DOORS ETC. <br />2 <br />3 <br />4 <br />2 <br />3 <br />4 <br />5 <br />6 <br />7 <br />3 <br />4 <br />3 <br />CODE ANALYSIS <br />PROJECT LOCATION <br />EGRESS PLAN <br />DEFERRED SUBMITTALS <br />FIRE ALARM SYSTEMFIRE SPRINKLER SYSTEM <br />5 <br />SCOPE OF WORK <br />CRUMBL COOKIES -LODI <br />2624 W KETTLEMAN LANE, SUITE 150LODI, CA 95242 <br />G0.0 <br />THESE DRAWINGS ARE PART OF A SET OF CONSTRUCTION DOCUMENTS. THE CONSTRUCTION DOCUMENTS CONSIST OF ONE OR MORE OF THE FOLLOWING ELEMENTS: <br /> CONSTRUCTION DRAWINGS SPECIFICATIONS STRUCTURAL CALCULATIONS CONTRACT FORMS AND CONDITIONS ADDENDA MODIFICATIONS AND REVISIONS <br />CONTRACTORS, SUBCONTRACTORS, AND OTHERS WHO PROVIDE LABOR AND/OR MATERIALS REFERENCING THESE DRAWINGS ARE RESPONSIBLE FOR OBTAINING AND REVIEWING ALL CURRENT CONSTRUCTION DOCUMENTS. <br />CONTRACTORS, SUBCONTRACTORS, AND OTHERS ARE TO REPORT ANY DISCREPANCIES OR ERRORS TO COMMERCIAL ARCHITECTURE IMMEDIATELY. ANY CHANGES TO THE PROJECT WILL BE VERIFIED WITH THE OWNER BY THE ARCHITECT AND REVISIONS WILL BE ISSUED BY ARCHITECT. CONTRACTORS ARE NOT TO MAKE ALTERATIONS OF ANY KIND WITHOUT THE PRIOR WRITTEN CONSENT OF ARCHITECT. DISCREPANCIES NOT REPORTED IMMEDIATELY ARE RESPONSIBILITY OF CONTRACTOR. <br />CONTRACTORS SHALL NOT SCALE FROM DRAWINGS. DIMENSIONS ARE PROVIDED TO ALLOW FOR ACCURATE CONSTRUCTION OF BUILDING. QUESTIONS ARISING FROM DIMENSIONS SHOULD BE RESOLVED BY CONTACTING ARCHITECT. <br />APPLICABLE CODE: 2019 CALIFORNIA BUILDING CODE (CBC) 2019 CALIFORNIA MECHANICAL CODE (CMC) 2019 CALIFORNIA PLUMBING CODE (CPC) 2019 CALIFORNIA ENERGY CODE 2019 CALIFORNIA ELECTRIC CODE (CEC) 2019 CALIFORNIA GREEN BUILDING STANDARDS CODE (CAL GREEN) <br />OWNERCRUMBL COOKIESJOHN GAUTHIER(209) 404-5780john@pizzapeople.net <br />DESIGN CONSULTANTSJZW ARCHITECTSKAYLYN BROUGHSARA SANDBERG135 E. CENTER ST.NORTH SALT LAKE, UT 84054(801) 936-1343saras@jzw-a.com <br />ARCHITECT OF RECORDCOMMERCIAL ARCHITECTURETHEODORE BRANDVOLD616 14TH STREETMODESTO, CA 95354(209) 271-8159 <br />MECHANICAL/ELECTRICAL/PLUMBING ENGINEERCOMMERCIAL ARCHITECTURETHEODORE BRANDVOLD616 14TH STREETMODESTO, CA 95354(209) 271-8159 <br />STRUCTURAL ENGINEERPELTON-WYLIE ENGINEERING, INC.2813 COFFEE ROAD, SUITE D1MODESTO, CA 95355(209) 575-9619 <br />CHAPTER 3: OCCUPANCY CLASSIFICATION AND USE302 CLASSIFICATION. BUSINESS: GROUP B 304 BUSINESS GROUP BFOOD PROCESSING ESTABLISHMENTS AND COMMERCIALKITCHENS NOT ASSOCIATED WITH RESTAURANTS,CAFETERIAS AND SIMILAR DINING FACILITIES NOT MORETHAN 2,500 SF IN AREA <br />CHAPTER 6: TYPES OF CONSTRUCTIONTYPE V-B <br />CHAPTER 9: FIRE PROTECTION AND LIFE SAFETY SYSTEMS903 AUTOMATIC SPRINKLER SYSTEMSEXISTING: EQUIPPED WITH AUTOMATIC SPRINKLERNFPA 13 FIRE SPRINKLER SYSTEM PROVIDED IN BUILDING <br />CHAPTER 10: MEANS OF EGRESS1004 OCCUPANT LOAD1004.5 DESIGN OCCUPANT LOAD -TABLE 1004.5 <br />FUNCTION OF SPACE LOAD FACTOR AREA # OCC.MERCANTILE:60 GROSS 208 SF 4KITCHENS, COMMERCIAL:200 GROSS 892 SF 5OCCUPIED SPACE 1100 SF 9 <br />EMPLOYEE RESTROOM NA 54 SF NATOTAL AREA 1154 SF 9 <br />1005 MEANS OF EGRESS SIZING1005.2 MINIMUM WIDTH BASED ON COMPONENTMIN 36" PROVIDED1006 NUMBER OF EXITS AND EXIT ACCESS DOORWAYSTABLE 1006.2.1 SPACES WITH ONE EXIT OR EXIT ACCESS DOORWAYOCCUPANCY:BOCCUPANT LOAD OF SPACE: <30COMMON PATH OF EGRESS TRAVEL DISTANCE W/ FS: <100FTONE EXIT REQUIRED FROM EACH SPACEONE EXIT PROVIDED FROM EACH SPACE <br />CALIFORNIA PLUMBING CODE, CHAPTER 4PLUMBING OCCUPANT LOAD PER 2019 CPC TABLE 422.1AOCCUPANT LOAD FOR ‘B’OCCUPANCY = 200 SF / PERSON= 1,003 SF / 200= 5 TOTAL OCCUPANTS= 3 MALE OCCUPANTS / 3 FEMALE OCCUPANTS <br />REQUIRED PLUMBING FIXTURES PER 2019 CPC TABLE 422.1REQUIRED PLUMBING FIXTURES FOR B OCCUPANCYMALE FIXTURES1 WATER CLOSET, 1 URINAL, 1 LAVATORYFEMALE FIXTURES1 WATER CLOSET, 1 LAVATORY <br />PROVIDED PLUMBING FIXTURESPER 2019 CPC 422.2, EXCEPTION 3“IN BUSINESS AND MERCANTILE OCCUPANCIES WITH A TOTAL OCCUPANT LOAD OF 50 OR LESS INCLUDING CUSTOMERS AND EMPLOYEES, ONE TOILET FACILITY, DESIGNED FOR USE BY NO MORE THAN ONE PERSON AT A TIME, SHALL BE PERMITTED FOR USE BY BOTH SEXES” <br />ONE UNISEX FIXTURE PROVIDED <br />• FIRE ALARM SYSTEM• FIRE SPRINKLER SYSTEM <br />DEFERRED SUBMITTAL NOTES:1. DEFERRED ITEMS SHALL BE SUBMITTED TO THE DESIGN PROFESSIONAL IN RESPONSIBLE CHARGE WHO SHALL REVIEW THEM AND FORWARD THEM TO THE BUILDING OFFICIAL WITH A NOTATION INDICATING THAT THE DEFERRED SUBMITTAL DOCUMENTS HAVE BEEN REVIEWED AND FOUND TO BE IN GENERAL CONFORMANCE TO THE DESIGN OF THE BUILDING WITHOUT ANY CORRECTIONS.2. DEFERRED APPROVAL ITEM PLANS AND SPECIFICATIONS WILL BE SUBMITTED SEPARATELY TO THE FIRE DEPARTMENT FOR APPROVAL PRIOR TO STARTING WORK ON THE PROJECT. SYSTEM DESIGN AND INSTALLATION SHALL BE IN ACCORDANCE WITH NFPA PAMPHLET #13 AND FIRE PREVENTION DEPARTMENT3. THE DEFERRED SUBMITTAL ITEM SHALL NOT BE INSTALLED UNTIL THE BUILDING OFFICIAL HAS APPROVED THEIR DESIGN AND SUBMITTAL DOCUMENTS REQUIREMENTS. <br />CONSTRUCTION OF INTERIOR PARTITION WALLS, TRANSACTION COUNTERS AND NEW FINISHES, INSTALLATION OF KITCHEN EQUIPMENT AND MECHANICAL, ELECTRICAL AND PLUMBING SYSTEMS AS REQUIRED BY RETAIL BAKERY FUNCTIONS AND APPLICABLE CODES. SCOPE OF WORK TO INCLUDE THE REUSE OF ELECTRICAL SERVICE PANEL AND EXISTING ROOF TOP UNIT. <br />San Joaquin County <br />Environmental Health Department <br />1868 E. Hazelton Ave. <br />Stockton, CA 95205 <br />(209) 468-3420 <br /> <br />APPROVED WITH CONDITIONS <br /> <br />For conditions, please see approval letter dated: <br /> <br />Approved by:_______________________Date:_______________ <br />10-14-20 <br />Oct 14, 2020 Stephanie Ramirez