Laserfiche WebLink
SOLID BLOCKING REQUIRED FOR GRAB BARS AND TISSUE DISPENSER.NOTE: <br />TISSUE DISPENSER. <br />42" MIN.12" MAX <br />54" MIN.39" - 41"39" - 41" <br />7" - 9"15" MIN.2"17" - 19"1 1/2" MIN.18" MIN.33" - 36"CL <br />*24" MIN. WHERE WALL SPACE DOES NOT PERMIT A 36" GRAB BAR <br />SOLID BLOCKING REQUIRED FOR GRAB BARS. GRAB BARS TO SUPPORT 250# FORCENOTE:17" - 19"33" - 36"12" MIN. <br />36" MIN. <br />24" MIN. <br />24" MIN.* <br />FLUSH VALVE ON OPEN SIDE OF TOILET.18" <br />MIRROR GRAB BAR. <br />PARTITION MOUNTED SANITARYNAPKIN DISPOSAL.PAPER TOWEL DISPENSER.ELECTRIC HAND DRYER. <br />FIRE EXTINGUISHER CABINET. <br />CL1 1/2" <br />TOILET TISSUE DISPENSER.40"MAX.60"33" - 36"34"44"40"MAX.7" -9" <br />SOAP DISPENSER.40"TOILET TISSUEDISPENSER. 15"MIN.MIN. KNEE CLEARANCE. <br />PROVIDE BLOCKING IN WALL FORATTACHMENT OF VANITY COUNTER. <br />PROVIDE PROTECTING INSULATION OVERSERVICE AND DRAIN PLUMBING.34" MAX.40" MAX.MIN.9"17" MIN.27" MIN.8" 3"MAX.VANITY TOP AS PER PLAN. <br />24" X 48" MIRROR. <br />COUNTER MOUNTED WASH BASIN WITH ACCESSIBLELAVATORY CONTROLS.7"27"34"MIN.40"MAX.GENDER SYMBOL:CORRESPONDING TOSCHEDULED SIGN (FEMALEFIGURE SHOWN) <br />INTERNATIONAL SIGN OF ACCESSIBILITY <br />1" HIGH LETTERS <br />RADIUS CORNERS (TYP) <br />REPEAT ALL TEXT IN CONTRACTED GRADE #2 BRAILLE <br />NOTES1. SIGN IS ENGRAVED LAMINATED ACRYLIC2. TEXT PER SIGNAGE SCHEDULE3. MOUNT ON WALL AT LATCH SIDE OF DOOR WITHIN 18" OF OPENING AND AT +5'-0" A.F.F TO CENTER LINE OF SIGN (TYPICAL, U.O.N.) <br />(TEXT) <br />(BRAILLE) <br />(UNISEX INDICATES USE OF BOTH FIGURES)6" FIELD8"3/8" - 1/2"32" MIN. CLEARANCE <br />24" MAX.32" MIN. CLEARANCECLEAR FLOOR SPACE30" MIN.CLEAR FLOOR SPACE48" MIN. <br />36" MIN. ACCESSIBLE COUNTER <br />MAX HEIGHT 34" A.F.F. <br />OF SHEETS <br />SLW <br />9/11/2020 <br />20-117 <br />DRAWN <br />AS SHOWN <br />SCALE <br />DATE <br />CHECKED <br />JOB NO. <br />SHEET <br />REVISIONS BY <br />TJBPROJECT :CLIENT :LOCATION :CRUMBLS COOKIES2624 W KETTLEMAN LN, 150LODI, CA 95242JOHN GAUTHIERLODI, CA1/2" = 1'-0"G1.1 <br />1 TYPICAL WATER CLOSET - SIDE VIEW <br />1/2" = 1'-0"G1.1 <br />2 TYPICAL WATER CLOSET - FRONT VIEW <br />1/4" = 1'-0"G1.1 <br />3 <br />MOUNTING HEIGHTS AND TOILET ROOM <br />ACCESSORIES <br />1/2" = 1'-0"G1.1 <br />4 TYPICAL VANITY DETAIL <br />1/2" = 1'-0"G1.1 <br />5 TYPICAL VANITY ELEVATION <br />3" = 1'-0"G1.1 <br />6 RESTROOM SIGNAGE <br />1/2" = 1'-0"G1.1 <br />8 CLEAR DOORWAY WIDTH - HINGED <br />1/2" = 1'-0"G1.1 <br />9 <br />CLEAR PASSAGEWAY WIDTH - MAX. <br />DEPTH <br />1/2" = 1'-0"G1.1 <br />7 SALES AND SERVICE COUNTER DETAIL <br />SINGLE ACCOMODATION TOILET FACILITIES: <br />THERE SHALL BE SUFFICIENT SPACE IN THE TOILET ROOM FOR A WHEELCHAIR MEASURING 30 INCHES WIDE BY 43 INCHES LONG TO ENTER THE ROOM AND PERMIT THE DOOR TO CLOSE. THERE SHALL BE IN THE ROOM A CLEAR FLOOR SPACE OF AT LEAST 60 INCHES IN DIAMETER, OR A T-SHAPED SPACE. NO DOOR SHALL ENCROACH INTO THIS SPACE. THE WATER CLOSET SHALL BE LOCATED IN A SPACE WHICH PROVIDES A MINIMUM 26-INCH-WIDE CLEAR SPACE FROM A FIXTURE OR A MINIMUM 32-INCH-WIDE CLEAR SPACE FROM A WALL AT ONE SIDE. THE OTHER SIDE SHALL PROVIDE 16" MIN-18" MAX FROM THE C ENTERLINE OF THE WATER CLOSET TO THE WALL. A MINIMUM OF 48 INCHES OF CLEAR SPACE SHALL BE PROVIDED IN FRONT OF THE WATER CLOSET. ALL DOORS, FIXTURES AND CONNNNNTROLS SHALL BE ON AN ACCESSIBLE ROUTE. <br />TOILET ROOM FIXTURES AND ACCESSORIES: <br />LAVATORY FIXTURES SHALL HAVE A CLEAR FLOOR SPACE OF 30 INCHES BY 48 INCHES. SUCH CLEAR FLOOR SPACE SHALL ADJOIN OR OVERLAP AS ACCESSIBLE ROUTE AND SHALL EXTEND INTO THE KNEE AND TOE SPACE UNDERNEATH THE LAVATORY. THE LAVATORY SHALL HAVE A MINIMUM KNEE CLEARANCE OF 29 INCHES AT THE FRONT AND MAY REDUCE TO 27 INCHES AT A POINT 6 INCHES FROM THE FRONT EDGE OF THE LAVATORY. ALL PIPES AND DRAINS SHALL BE SUFFICIENTLY WRAPPED FOR KNEE AND LEG PROTECTION. FAUCET CONTROLS AND OPERATING MECHANISMS, SHALL BE OPERABLE WITH ONE HAND AND SHALL NOT REQUIRE TIGHT GRASPING, PINCHING OR TWISTING OF THE WRIST. THE FORCE REQUIRED TO ACTIVATE CONTROLS SHALL BE NO GREATER THAN 6LBF. LEVEL-OPERATED, PUSH-TYPE AND ELECTRONICALLY CONTROLLED MECHANISMS ARE EXAMPLES OF ACCEPTABLE DESIGNS. SELF-CLOSING VALVES ARE ALLOWED IF THE FAUCET REMAINS OPEN FOR AT LEAST 10 SECONDS. MIRRORS SHOULD BE MOUNTED WITH THE BOTTOM EDGE NO HIGHER THAN 40 INCHES FROM THE FLOOR, WHERE TOWEL, SANITARY NAPKINS, WASTE RECEPTACLES, AND OTHER SIMILAR DISPENSING AND DISPOSAL FIXTURES ARE PROVIDED. AT LEAST ONE OF EACH TYPE SHALL BE LOCATED WITH ALL OPERABLE PARTS, INCLUDING COIN SLOTS, WITHIN 40 INCHES FROM THE FINISHED FLOOR. TOILET TISSUE DISPENSERS SHALL BE LOCATED ON THE WALL OR PARTITION 7 INCHES MINIMUM AND 9 INCHES MAXIMUM IN FRONT OF THE WATER CLOSET MEASURED TO THE CENTER LINE OF THE DISPENSER, MOUNTED BELOW THE GRAB BAR WITH THE OUTLET OF THE DISPENSER AT A MINIMUM HEIGHT OF 19 INCHES ABOVE THE FLOOR. DISPENSERS THAT CONTROL DELIVERY OR THAT DO NOT PERMIT CONTINUOUS PAPER FLOW SHALL NOT BE USED. WHERE URINALS ARE PROVIDED AT ONE SHALL HAVE A CLEAR FLOOR SPACE 30 INCHES BY 48 INCHES IN FRONT OFTHE URINAL TO ALLOW FORWARD APPROACH. <br />WATER CLOSET NOTES: <br />1. THE CONTROLS SHALL BE OPERABLE WITH ONE HAND AND SHALL NOT REQUIRE TIGHT GRASPING, PINCHING OR TWISTING.2. CONTROLS FOR THE FLUSH VALVES SHALL BE MOUNTED ON THE WIDE SIDE OF THE TOILET AREAS, NO MORE THAN 44 INCHES ABOVE THE FLOOR.3. THE FORCE REQUIRED TO ACTIVATE CONTROLS SHALL BE NO GREATER THAN 5 POUNDS-FORCE.4. TOILET PAPER DISPENSERS SHALL NOT BE OF A TYPE THAT CONTROLS DELIVERY OR THAT DOES NOT ALLOW CONTINUOUS PAPER FLOW. 2019 CBC 11-B-604.7. <br />LAVATORY NOTES: <br />1. FAUCET CONTROLS AND LAVATORY MECHANISMS SHALL COMPLY WITH 2019 CBC SECTION 11B-309.2. WATER SUPPLY AND DRAIN PIPES SHALL BE INSULATED OR OTHERWISE COVERED PER 2019 CBC SECTION 11B -606.5.3. THERE SHALL BE NO SHARP OR ABRASIVE SURFACES UNDER LAVATORIES - 2019 CBC SECTION 11B - 606.5. <br />DOOR SIGNAGE NOTES <br />SANITARY FACILITIES: <br />WHERE SEPARATE FACILITIES ARE PROVIDED FOR NON-DISABLED PERSONS OF EACH SEX, SEPARATE FACILITIES SHALL BE PROVIDED FOR PERSONS WITH DISABLITIES OF EACH SEX ALSO. WHERE UNISEX FACILITIES ARE PROVIDED FOR NON-DISABLED PERSONS, SUCH UNISEX FACILITIES SHALL BE PROVIDED FOR PERSONS WITH DISABILITIES. PASSAGEWAYS LEADING TO SANITARY FACILITIES SHALL HAVE CLEAR ACCESS. <br />ALL DOORWAYS LEADING TO SUCH SANITARY FACILITIES SHALL HAVE1. A CLEAR UNOBSTRUCTED OPENING WIDTH OF AT LEAST 32 INCHES.2. A LEVEL AND CLEAR AREA FOR A MINIMUM DEPTH OF 60 INCHES IN THE DIRECTION OF THE DOOR SWING AS MEASURED AT RIGHT ANGLES TO THE PLANE OF THE DOOR IN ITS CLOSED POSITION, AND 44 INCHES WHERE THE DOOR SWINGS AWAY FROM THE LEVEL AND CLEAR AREA. THE WIDTH OF THE CLEAR AREA ON THE SIDE TO WHICH THE DOOR SWINGS SHALL EXTEND 24 INCHES PAST THE STRIKE EDGE OF THE DOOR FOR EXTERIOR DOORS AND 18 INCHES PAST THE STRIKE EDGE FOR INTERIOR DOORS. <br />IDENTIFICATION SYMBOLS FOR SANITARY FACILITIES: <br />SANITARY FACILITIES ARE REQUIRED TO PROVIDE TWO SEPARATE TYPES OF SIGNAGE, ONE TYPE LOCATED ON THE DOORWAY TO THE FACILITY AND ANOTHER TYPE MOUNTED ON THE WALL ADJACENT TO THE LATCH SIDE OF THE DOOR. <br />DOOR MOUNTED SIGNAGE: <br />MEN'S - EQUILATERALR TRIANGLE 1/4" THICK WITH EDGES 12" LONG AND A VERTEX POINTING UPWARD.WOMEN'S - 12" DIAMETER CIRCLE 1/4" THICKUNISEX - 12" DIAMETER CIRCLE 1/4" THICK WITH 1/4" THICK TRIANGLE SUPERIMPOSED WITHIN CIRCLE. <br />THESE GEOMETRIC SYMBOLS SHALL BE CENTERED ON THE DOOR AT A HEIGHT OF 58"-60" A.F.F. AND THEIR COLOR SHALL BE DISTINCTLY DIFFERENT FROM THE COLOR AND CONTRAST OF THE DOOR. THE EDGES OF THE SIGN ARE TO BE ROUNDED, CHAMFERED OR EASED, AND ANY CORNERS MUST HAVE A MINIMUM RADIUS OF 1/8". <br />WALL MOUNTED SIGNAGE: <br />THE INTERNATIONAL SYMBOL OF ACCESSIBILITY IS TO BE INSTALLED ON THE WALL ADJACENT TO THE LATCH SIDE OF THE DOOR. THE BORDER DIMENSION OF THIS PICTOGRAM SHALL BE A MINIMUM OF 6" IN HEIGHT. A VERBAL DESCRIPTION AS TO THE RESTROOM USAGE (I.E. MEN'S, ETC.) SHALL BE PLACED DIRECTLY BELOW THE SYMBOL OF ACCESSIBILITY. THE CHARACTERS AND BACKGROUND OF THE SIGN IS TO BE EGGSHELL, MATTE OR OTHER NON-GLARE FINISH AND THE COLOR AND CONTRAST OF THE SIGN SHALL DISTINCTIVELY CONTRAST WITH THE COLOR AND CONTRAST OF THE WALL. THE LETTERS AND NUMERALS ARE TO BE RAISED 1/32" WITH MIN. 5/8" AND MAX 2" HEIGHT BASED ON UPPERCASE "I". UPPERCASE "O" IS TO BE 60% MIN AND 110% MAX THE SIZE OF THE UPPERCASE "I". STROKE THICKNESS OF UPPERCASE LETTER "I" SHALL BE 15% MAX OF THE HEIGHT OF THE CHARACTER. ALL FONT TO BE SANS-SERIF UPPERCASE CHARACTERS AND ACCOMPANIED BY GRADE 2 BRAILLE. THESE WALL SIGNS SHALL BE CENTERED AT HEIGHT SHOWN ABOVE AND LOCATED TO ALLOW A PERSON TO APPROACH WITHIN 3" OF SIGNAGE WITHOUT ENCOUNTERING PROTRUDING OBJECTS OR STANDING WITHIN SWING OF THE DOOR. SIGNS CONTAINING TACTILE CHARACTERS SHALL BE LOCATED SO THAT A CLEAR FLOOR SPACE OF 18" MIN X 18" MIN, CENTERED ON THE TACTILE CHARACTERS, IS PROVIDED BEYOND THE ARC OF ANY DOOR SWINGS BETWEEN THE CLOSED AND 45 DEGREE OPEN POSITION (CBC 11-B703.4.2) <br />G1.1