Laserfiche WebLink
Project Name:Nonresidential Building NRCC-PRF-01-E Page 1 of 16 <br />Project Address:610 West Kettleman Lane Lodi 95240 Calculation Date/Time:14:44, Wed, Feb 17, 2021 <br />Input File Name:2020-121 Takeoff.cibd19x <br />CA Building Energy Efficiency Standards- 2019 Nonresidential Compliance Report Version: NRCC-PRF-01-E-11022020-6384 Report Generated at: 2021-02-17 14:45:26 <br />A. GENERAL INFORMATION <br />1.Project Location (city)Lodi 8.Standards Version Compliance2019 <br />2.CA Zip Code 95240 9.Compliance Software (version)EnergyPro 8.2 <br />3.Climate Zone 12 10.Weather File STOCKTON_724920_CZ2010.epw <br />4.Total Conditioned Floor Area in Scope 36,373 ft2 11.Building Orientation (deg)(N) 0 deg <br />5.Total Unconditioned Floor Area 11,209 ft2 12.Permitted Scope of Work ExistingAdditionAndAlteration <br />6.Total # of Stories (Habitable Above Grade)1 13 Building Type(s)Nonresidential <br />7.Total # of dwelling units 0 14 Gas Type NaturalGas <br />B. PROJECT SUMMARY <br />Table Instructions: Table B shows which building components are included in the performance calculation. If indicated as not included, the project must show compliance prescriptively if within <br />permit application. <br />Building Components Complying via Performance Building Components Complying Prescriptively <br />Envelope (see Table G) <br />Performance <br />Covered Process: Commercial <br />Kitchens <br />Performance The following building components are ONLY eligible for prescriptive <br />compliance and should be documented on the NRCC form listed if within <br />the scope of the permit application (i.e. compliance will not be shown <br />on the NRCC-PRF-E). <br />Not Included Not Included <br />Mechanical (see Table H) <br />Performance <br />Covered Process: Computer Rooms <br />Performance Indoor Lighting (Unconditioned)§140.6 NRCC-LTI-E <br />Not Included Not Included Outdoor Lighting §140.7 NRCC-LTO-E <br />Domestic Hot Water (see Table I) <br />Performance <br />Covered Process: Laboratory Exhaust <br />Performance Sign Lighting §140.8 NRCC -LTS-E <br />Not Included Not Included Mandatory Measures <br />Lighting ( Indoor Conditioned, see <br />Table K) <br />Performance <br />Electrical power systems, commissioning, solar ready, elevator and <br />escalator requirements are mandatory and should on the NRCC form <br />listed if applicable (i.e. compliance will not be shown on the <br />NRCC-PRF-E.) <br />Not Included Electrical Power Distribution S110.11 NRCC-ELC-E is required <br />Solar Thermal Water Heating (see <br />Table I) <br />Performance Commissioning S120.8 NRCC-CXR-E is required <br />Not Included Solar Ready S110.10 NRCC-SRA-E is required