Laserfiche WebLink
E2 GENERAL NOTES <br /> -- --------------------------—--—--— -— -— —- —- -- --— -— -------- --- ------ --------------------------_---_------------------------------ <br /> - -- -- -- -- -- - - - - -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- - 1 ALL DIMENSIONS ARE TO ACE 0 STUD UNLESS OTHERWISE <br /> 1 ---------- ------ 14 -- -- -- - -- - -- --� -- -- -- - -- - -- - -- - -- -- - -- -- �-- NOTED. "CLEAR" DENOTES FINISH TO FINISH DIMENSIONS. <br /> i 3'-0" 14'-10" -- - 1- - rr <br /> I i HOLD DENOTES CRITICAL FRAMING DIMENSIONS.EXISTVSAC DESIGN <br /> CLR 4—FT HIGH WALL v <br /> 2 1 a EXISTING WALKININ , <br /> WALK-IN COOLER FREEZER III 2. MOUNT FIRE EXTINGUISHERS LISTED IN SPECIFICATIONS <br /> ' ; III AT LOCATIONS SHOWN OR DIRECTED BY FIRE DEPT. P❑ Box Sacramento, <br /> C <br /> o 1 '-tt ;; ; PROVIDE ADD'L IF REQ'D BY FIRE DEPT. TeU 916752,202295816 <br /> I �--o <br /> F�9 <br /> -2 <br /> 13 i -- -- -- -- -- -- 1L i i - -- - - - -- - i <br /> I I (N) KITCHEN i i � -- -- -- -- -- -- -- --� , � II <br /> . ,. . <br /> F-2 2 ° ; , <br /> The use of these drawings and <br /> B-3 C-2 I I III I specifications shall be restricted to <br /> he specific a or which they re <br /> ❑ � -- - --- ._- � ,� � t eci site f w h th we <br /> 4<a) <br /> 4 <br /> III ,\ ,- I / III prepared and publication thereof <br /> � � <br /> shall be expressly limited to such <br /> use. Re-use, reproduction or <br /> F" <br /> WH 5 FINISH PLAN KEY NOTES publication by any method in whole <br /> 0 - or part is prohibited. Title to these <br /> plans and specifications shall remain <br /> ---- ------- - -- --❑ i ; III I I-- -- -- -- -- -- - -- i j ' ; III with VSAC Design without prejudice, <br /> 1 11 9 8 76 ' ' / / I ' FLOOR and visual contact with them shall <br /> 2 <br /> I I III � ; o I <br /> I I <br /> constitute primaevidence acre eence o <br /> CiD 12'-0" <br /> acceptance of these restrictions. <br /> TYPE 1 HOOD F-1 (E) CERAMIC TILE ® <br /> VSAC Design <br /> 6"x6" QUARRY TILE <br /> II I ' II III I I I <br /> BASE REVISIONS By <br /> ------- -------- -- -- -- <br /> III I I I B-1 (E) WOOD BASE <br /> EXISTING RETAIL ' ' ' <br /> 1 III I I % j j ; III B-2 (E) 4"x 3/8" INTEGRAL CERAMIC TILE COVE BASE <br /> O F-1 W-1 <br /> 4"x 3/8" INTEGRAL QUARRY TILE COVE BASE <br /> I I '------- J� <br /> -- „ ; <br /> WALL <br /> Fye ==J <br /> B�2 C-2 � EXISTING UNISEX <br /> , SEMI GLOSS ENAMEL <br /> ACCESSIBLE RESTROOM (E) PAINTED GYP. BD. - <br /> FRP WAINSCOTT - 8-FT HEIGHT <br /> IIII II I <br /> I L <br /> CEILING <br /> II II II � � II <br /> C-1 (E) 24x48 SUSPENDED CEILING <br /> W <br /> C-2 24x48 SUSPENDED CEILING W/HITE SMOOTH WASHABLE TILE <br /> II II I II W Q <br /> --------------------------------------------------- <br /> L_ <br /> , <br /> II ----------------------------------- II II <br /> _ <br /> II L_�� L_�� <br /> LEGEND C1) O <br /> EXISTING WALL TO REMAIN <br /> z _J <br /> Q Q <br /> E1 4-FT HIGH PARTITION Qf , <br /> 2x4 WOOD STUD @ 16" OC W/ V8" G.W.B. BOTH SIDES Q v <br /> ❑® FLOOR SINK C/) <br /> FLOOR /EQUIPMENT PLAN CEILING PLAN = M v <br /> 1 2 FLOOR DRAIN w <br /> SCALE: 3/16" = 1'-0" SCALE: 3/16" = 1'-0" O <br /> Q � Z <br /> WORK IN CEILING LIMITED TO RELOCATING LIGHTING EXISTING RECESSED 2'x4' FLUORESCENT LIGHT <br /> FIXTURES AND HVAC REGISTERES TO ACCOMODATE C <br /> NEW HOOD. G <br /> ALL LIGHTINGS ARE EXISTING <br /> EXISTING SURFACE-MOUNTED 1'x4' FLUORESCENT LIGHT <br /> EQUIPMENT SCHEDULE ® DOOR SCHEDULE Drawing <br /> ITEM CITY DESCRIPTION MANUFACTURE MODEL NO. ELECTRICAL GAS REMARKS <br /> VOLTS/PHASE AMPS HP KW (kVA) CONN.TYPE MBTU DOOR SIZE MATERIAL REMARKS <br /> 1 PREP SINK ADVANCE TABCO FE-1-1824-24-X w/ LEFT SPASHGUARD ROOM NAME <br /> �2 1 REFRIGERATED SANDWICH PREP UNIT TRUE FOOD SERVICE TSSU-48-12 115/1 8.6 1/3 NEMA 5-15P SELF-CONTAINED HEIGHT WIDTH THK. DOOR FRAME <br /> 1 WALL-MOUNTED HAND SINK GSW HS-1615S w/SPLASHGUARD ON BOTH SIDES FLOOR/EQUIP PLA N <br /> ENTRANCE E1 EXISTING SELF-CLOSING <br /> 7'-0" 2x3'-0" 1-3/4" ALUM/GLASS ALUM <br /> ® 1 3-COMP SINK ADVANCE TABCO FC-3-1620-24RL DRAIN TO FLR SINK W/ PANIC HARDWARE <br /> 1 (E)WATER HEATER RHEEM XG50T12HE4000 36 <br /> © 1 (E) MOP SINK ADVANCE TABCO 8-OP-16 RESTROOM 1 6'-8" 3'-0" 1-3/4" WOOD WOOD SELF-CLOSING W/ KICKPLATE <br /> 0 1 FRYER PITCO FRIALATOR SG14-S 110 <br /> ® 1 24-IN COUNTERTOP GRIDDLE IMPERIAL IMGA-2428 60 <br /> 1 4-BURNER RANGE AMERICAN RANGE AR-4 155 KITCHEN E2 6'-8" 5'-0" 1-3/4" 16GA STL STL SELF-CLOSING W/ KICKPLATE " <br /> '• �tOFESS/� '' <br /> 10 1 12-FT TYPE 1 HOOD(SEE HOOD PLAN) CAPTIVE AIRE 5430 ND-2 ��Q • .. D," <br /> 11 1 PROOFER METRO C539-CFC-U 120/60/1 12 1.4 NEMA 5-20P 71"x18"x26" PROOFING MODULE <br /> 12 1 MIXER HOBART HL400 240/60/1 9.3 2.2 <br /> 13 1 FIRE EXTHINGUISHER-TYPE K DOOR NOTES: z <br /> N0. C 60696 <br /> 14 1 EMPLOYEE LOCKER HELMAX EL-5 D1. EXIT DOORS SHALL BE ABLE TO BE OPENED FROM THE D3. ALL DOORS ARE TO HAVE LEVER TYPE HARDWARE, * EXP. 12131120 *; <br /> INSIDE W.0 THE USE OF A KEY OR ANY SPECIAL UNLESS OTHERWISE NOTED AS PANIC HARDWARE �9T''.,,CIVIC •.• ���; <br /> KNOWLEDGE OR EFFORT. (LEVER AT PULL SIDE), MOUNTED AT HEGHT BETWEEN .......... <br /> OF CA... <br /> 34" TO 44" A.F.F. <br /> D2. THE MAXIMUM EFFORT TO OPERATE DOORS SHALL NOT <br /> EXCEED 5 LBS FOR ALL DOORS, EXCEPT FIRE DOORS, D4. DOOR CLOSER SHALL BE ADJUST SUCH THAT FROM AN <br /> WHICH MAY HAVE A MAXIMUM EFFORT OF 15 LBS. OPEN POSITION OF 90' THE DOOR WILL TAKE A MINIMUM <br /> FORCES APPLIES AT RIGHT ANLGE TO THE DDDR. OF 5 SECONDS TO MOVE THE DOOR TO A POSITION OF <br /> 12' FROM THE LATCH Pro'. No. <br /> Drawn HDV <br /> w <br /> Date o <br /> a <br /> Scale 10-2-20 <br /> Sheet <br /> A - 1 <br /> Sheet No. of Total Sheets <br />